The heat use in individually heated dwellings is reduced if the dwellings are put together in MU-dwelling buildings. It is not the insulation that is changed it is the balance temperature that is increased. The balance temperature is the temperature in a dwelling with closed heaters. The cost for the building and the used heat at a temperature increase in a dwelling is the heat loss out. It is optimal or it gives the highest standard of living if the marginal cost of temperature is for the heat loss out. This is possible if the measured heat to a dwelling is reduced with the variable part in a two part tariff. The rest of the cost of heat is covered with the fixed part. This is important if individual heat cost allocation is used.