Mid Sweden University

miun.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Funktion och åtgärdsbehov i en dagvattendamm: Hydraulik, sedimentation och PFAS i ytvatten
Mid Sweden University, Faculty of Science, Technology and Media, Department of Natural Science, Design, and Sustainable Development (2023-).
2026 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Coop-dammen i Lillänge handelsområde i Östersunds kommun är en befintlig dagvattenanläggning som avvattnas mot Lillsjön och vidare mot Storsjön. Området ligger inom skyddsområdet för Minnesgärdets ytvattentäkt och ingår i ett lokalt PFAS-påverkat avrinningssammanhang. Syftet med studien var att översiktligt bedöma dammens nuvarande funktion avseende fördröjning, hydraulik och sedimentation, samt att sammanställa tillgängliga PFAS-data från dammens ytvatten.Studien genomfördes som en fallstudie baserad på litteratur, fältobservationer, översiktliga mätningar, hydrauliska beräkningar, teoretisk sedimentationsberäkning samt tidigare och egna PFAS-data. Fördröjningsförmågan bedömdes genom jämförelse mellan tillgänglig reglervolym och beräknad erforderlig fördröjningsvolym för 2- och 20-årsregn. Sedimentationsförutsättningarna bedömdes teoretiskt i relation till målet om minst 90 % avskiljning av partiklar ≥125 µm vid 2-årsregn.Resultaten visar att den tillgängliga reglervolymen, ca 54 m³, är liten i förhållande till beräknad erforderlig fördröjningsvolym. Dammen kan teoretiskt nå 90–99 % avskiljning av partiklar ≥125 µm, men fältobservationer av skadat eller otätt utlopp, låg reglerhöjd, uppgrundade delar och tydlig mittfåra tyder på att den praktiska funktionen är mer begränsad. Tidigare PFAS-data från 2020–2024 visar återkommande halter över använda jämförelsevärden för PFOS och PFAS25/PFOA-ekv., medan PFAS11 överskred jämförelsevärdet vid flera tillfällen. De egna proverna från 2026 gav ett kompletterande men begränsat underlag.Studien visar sammantaget att Coop-dammen bör ses som en möjlig del av en behandlingskedja. Dammens grundfunktion behöver först klarläggas, särskilt avseende utlopp, reglerhöjd, sedimentmängd och flödesfördelning. Därefter kan behovet av kompletterande åtgärder bedömas, samtidigt som PFAS-relaterad spridningsbegränsning utreds som ett separat spår.

Abstract [en]

The Coop stormwater pond in the Lillänge commercial area in Östersund municipality drains towards Lake Lillsjön and further to Lake Storsjön. The pond is located within the protection zone of the Minnesgärdet surface water supply and is part of a locally PFASimpacted catchment. The aim of this study was to provide an overview assessment of the pond’s current function regarding detention, hydraulics and sedimentation, and to compile available PFAS data from its surface water.The study was conducted as a case study based on literature, field observations, overview measurements, hydraulic calculations, theoretical sedimentation calculations, and previous and new PFAS data. Detention capacity was assessed by comparing available detention volume with calculated required detention volume for 2- and 20-year rainfall events. Sedimentation conditions were assessed theoretically against the target of at least 90 % removal of particles ≥125 µm during a 2-year rainfall event.The results show that the available detention volume, approximately 54 m³, is small compared with the calculated required detention volume. The pond can theoretically achieve 90–99 % removal of particles ≥125 µm. However, field observations of a damaged or leaking outlet, low regulation height, shallow areas and a distinct central channel indicate that the practical function may be more limited. Previous PFAS data from 2020–2024 show recurring concentrations above the applied comparison values for PFOS and PFAS25/PFOA-eq., while PFAS11 exceeded the comparison value on several occasions. The 2026 samples provided supplementary but limited information.Overall, the Coop stormwater pond should be regarded as a possible part of a treatment train. The pond’s core function first needs to be clarified, particularly regarding outlet function, regulation height, sediment quantity and flow distribution. Thereafter, the need for additional measures can be assessed, while PFAS-related mitigation is investigated as a separate track.

Place, publisher, year, edition, pages
2026. , p. 63
Keywords [en]
stormwater pond, detention, sedimentation, PFAS, stormwater treatment
Keywords [sv]
dagvattendamm, fördröjning, sedimentation, PFAS, dagvattenrening
National Category
Environmental Management
Identifiers
URN: urn:nbn:se:miun:diva-58837OAI: oai:DiVA.org:miun-58837DiVA, id: diva2:2109162
Subject / course
Environmental Engineering MM1
Educational program
Ecotechnology NEKOG 180 higher education credits
Supervisors
Examiners
Note

2026-06-05

Available from: 2026-10-08 Created: 2026-10-08 Last updated: 2026-10-08Bibliographically approved

Open Access in DiVA

fulltext(2763 kB)24 downloads
File information
File name FULLTEXT01.pdfFile size 2763 kBChecksum SHA-512
22a4e4bae61233df898e30e46a0511699345943be3e1c13322cd6d56dd604766aadf6a49ca1ff1f204e77a6185db8867fc36dd6fbcecb0b3224d31da9ac9a1e1
Type fulltextMimetype application/pdf

By organisation
Department of Natural Science, Design, and Sustainable Development (2023-)
Environmental Management

Search outside of DiVA

GoogleGoogle Scholar
Total: 24 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 39 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf