Mid Sweden University

miun.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Termoisolation: Ett utredande arbete för Didriksons
Mid Sweden University, Faculty of Science, Technology and Media, Department of Engineering, Mathematics, and Science Education (2023-).
2018 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Denna studie är ett examensarbete utfört under sista året av tre på Sportteknologiprogrammet vid Mittuniversitetet i Östersund. Syftet med studien är att ge det svenska klädföretaget Didriksons svar på frågan om vilken av de vadderingar använda i deras produktion besitter bäst isoleringsförmåga och vilka faktorer som kan påverka den. Målet var att kunna presentera ett fullgott resultat från alla studier för Didriksons som de senare förhoppningsvis kan ha hjälp utav i sin fortsatta produktutveckling. För att besvara frågan har tester av 9 likvärdiga jackor tillverkade med olika isoleringsmaterial och konstruktionsprinciper utförts i laboratorium, bland annat i kylkammaren på Nationellt Vintersportcentrum tillsammans med vindtunneln och textillaboratoriet på Sports Tech Research Centre vid Mittuniversitetet i Östersund. Testerna har inte följt någon standard utan är utvecklade tillsammans med studenten, Didriksons och personer med expertis inom området vid universitetet. Undersökningen har visat att den jacka som hade den bästa isoleringsförmågan var den isolerad med syntetiskt dun. Studien har också påvisat att så kallade cold spots, i form av sömmar, dragkedjor och andra attiraljer som på något sätt stör vadderingen, har stor påverkan på isoleringsförmågan. Jackor med samma typ av isolering men med olika mängd av cold spots har presterat bäst respektive sämst i testerna. De olika vadderingarna har även undersökts i laboratorium för att se dess vindtäthet och analysera dess mikrostruktur, allt för att skapa förståelse för materialens olika egenskaper.

 

Abstract [en]

This study is a thesis during the last semester of three years at the SportsTechnology program at the Mid Sweden University in Östersund. Theaim of the study is to give the swedish clothing brand Didriksons ananswer to the question of which padding used in their production thathas the best thermal insulation properties and which factors that mayhave an impact on it. The goal for this study is to present a satisfactoryresult for Didriksons from all the executed tests combined which laterhopefully will help them within their product development. To answerthat question, nine equal jackets with different isolation materials andways of construction have been tested in various laboratories such as thecold chamber at National Wintersport Centre and the wind tunnel atSports Tech Research Centre all within the Mid Sweden University. Thetests have not been according to any ISO-standards or such, but hasbeen produced by the student together with Didriksons and researcherswith expertise within the subject at the university. Studies showed thatthe jacket with the best thermal isolation property was the onefabricated with synthetic down. The study also showed that so calledcold spots, stiches, zippers and so on, may affect the padding whichresults in a big negative impact to the thermal isolation, especially whenthe garment is exposed to wind. Jackets with the same type of paddingbut different amounts of cold spots have delivered the best and theworst results during the tests. The different paddings have also beeninvestigated in laboratories to see how they withstand wind and toanalyze their micro structure. All this to get a better understanding ofthe materials and its various properties.

Place, publisher, year, edition, pages
2018. , p. 91
Keywords [en]
Textile study, Sports technology, Thermal isolation, Jackets, Outerwear, Garment, Cold chamber, Wind tunnel
Keywords [sv]
Termoisolation, Jackor, Isolering, Kläder, Kylkammare, Vaddering
National Category
Other Mechanical Engineering
Identifiers
URN: urn:nbn:se:miun:diva-50294OAI: oai:DiVA.org:miun-50294DiVA, id: diva2:1830485
External cooperation
Didriksons
Subject / course
Mechanical Engineering MT1
Educational program
Sportteknologi - maskiningenjör inom innovativ produktutveckling TSPMG 180 GR
Supervisors
Examiners
Available from: 2024-01-23 Created: 2024-01-23 Last updated: 2025-09-25

Open Access in DiVA

fulltext(12038 kB)99 downloads
File information
File name FULLTEXT01.pdfFile size 12038 kBChecksum SHA-512
4370b29e4faacb4236781e6bf2bed6c9480dbb913657f27170d3a18e4a48b08bdf43b7fddf21e5020b5d3391b70e13327000ee91f16817b31de39f18cff71a29
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Carlsson, Jonna
By organisation
Department of Engineering, Mathematics, and Science Education (2023-)
Other Mechanical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 101 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 158 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf