Energikartläggning av Härnösands simhall
Mid Sweden University, Faculty of Science, Technology and Media, Department of Natural Science, Design, and Sustainable Development (2023-).
2023 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Simhallar är en byggnadstyp med stor energianvändning. Härnösands simhall har en månatlig elenergianvändning på 100 000 kWh, vilket motsvarar fyra normalvillors årsanvändning. Arbetets syfte är att beräkna var energin används och se vilka energieffektiviseringsmöjligheter det finns för att minska användningen. Energikartläggningen har gjorts genom att samla in information från besök på anläggningen, driftkort, ritningar, avläsa värden på enheter, pumpar och värmeväxlare och prata med driftpersonal. Simhallen består av en 25-metersbassäng, en undervisningsbassäng, plaskavdelning, relax, gym och restaurang. Den renoverades under 2010. Härnösands simhall har en energifördelning och energianvändning som liknar genomsnittliga simhallar. Härnösand använder 2 700 MWh per år i total inköpt energi, där både fjärrvärme och el ingår. Den har en energianvändning på 13,6 kWh/besökare medan andra tidigare beräknade simhallar ligger mellan 8–24 kWh/besökare. Simhallen använder 50–100 kWh per timme under natten och 180 – 230 kWh under en timme då simhallen är öppen. Simhallen har ett över lag gott energitekniskt utformande. De områdena med tydligast potential för energieffektivisering är spillvatten från duschar, belysning och ventilation. Årligen spolas 200 000 kWh i avloppet med duschvatten. Det krävs troligtvis för stora insatser för att kunna tillgodogöra sig den energin. Belysningen och ventilationen har en del potential att kunna minska energianvändningen, men det har inte gått att beräkna.  Härnösands simhalls energi fördelas genomsnittligt och energianvändningen per besökare är genomsnittlig, jämfört med sju andra badhus.

Abstract [en]

Public baths are a high consumer of energy. Each month the electricity energy use in Härnösand’s public bath, Härnösands simhall, is close to 100,000 kWh, which is equivalent to four standard Swedish villas annual electricity consumption. The purpose of this thesis is to calculate where the energy is used in this public bath and to see if there are any possible energy efficiency measures. The public bath includes a 25 meters swimming pool, a teaching pool, a toddler splash pool area, a wellness area with warm pools and saunas, a gym, and a restaurant. The energy mapping has been made by visits, reading operating cards and drawings, collecting data values from units and heat exchangers, and talking to operating staff. Härnösand’s public bath has energy use similar to other Swedish public baths. The facility used 2,700 MWh of energy in 2022, district heating and electricity included, which is 13,6 kWh/swimmer, while other public baths use 8-24 kWh/swimmer. In one hour at night the facility uses 50-100 kWh per hour. An hour during opening hours the same value is 180-230 kWh. The facility is energy efficient well designed since renovated in 2010. Although there are three areas with the clearest potential in energy efficiency: shower wastewater, lighting, and ventilation. Annually, 200,000 kWh are flushed down the drain with shower water. It probably requires too much effort to be able to take advantage of it. The lighting and ventilation have some potential to reduce energy use, but it has not been possible to calculate. The energy use of Härnösand´s public bath is average compared to other Swedish public baths.  

Place, publisher, year, edition, pages
2023. , p. 54
Keywords [sv]
Energikartläggning, badhus, energieffektivisering
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:miun:diva-48784OAI: oai:DiVA.org:miun-48784DiVA, id: diva2:1778603
Subject / course
Energy Technology EN2
Educational program
Energy Engineering TENIG 180 higher education credits
Supervisors
Examiners
Available from: 2023-07-03 Created: 2023-07-03 Last updated: 2025-09-25Bibliographically approved

Open Access in DiVA

fulltext(2413 kB)223 downloads
File information
File name FULLTEXT01.pdfFile size 2413 kBChecksum SHA-512
60b8c26ac5fc891eeb8a282160a2c0639cdf462f607b9193cfc382a6dc05e37f6d0d34d8ef752aa09febd5a47d4e004e02ad2b047ed319d95dd4823106cb9946
Type fulltextMimetype application/pdf

By organisation
Department of Natural Science, Design, and Sustainable Development (2023-)
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 224 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 259 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf