Betongoptimering av bärande innerskivor isandwichelement: Vad innebär minskad betongvolym för de direkta utsläppenav växthusgaser?
Mid Sweden University, Faculty of Science, Technology and Media, Department of Ecotechnology and Suistainable Building Engineering.
2022 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Under 2019 stod Bygg- och fastighetssektorn för 21 procent avSveriges totala utsläpp av växthusgaser. Sett till ett intervall från1993 fram till 2019 har det totala utsläppet av växthusgaserminskat. Det beror på att utsläppen vid uppvärmning reducerats.Studeras enbart utsläppen vid renovering och byggnation harutsläppen ökat nämnvärt under samma intervall. För att brytadenna trend av ökade växthusgaser vid renovering och byggnationkrävs det att Bygg- och fastighetssektorn reagerar och utvecklaralternativa lösningar. Ett alternativ till att minska utsläpp är attdimensionera slankare konstruktioner som kräver mindre material.Betongkonstruktioner utgör en betydande andel av utsläpp avväxthusgaser. Betongindustrins dåliga utgångspunkt ger ettslagkraftigt initialläge i att klimatförbättra kommandekonstruktioner. Denna studie har utförts åt Attacus Stomsystemmed syftet att undersöka hur ett pelar-balksystem medförtunningar för bärande innerskivor i sandwichelement påverkarde direkta utsläppen av växthusgaser. Studien har studerat ettfiktivt väggelement som utsätts för 5, 10, 15 och 20 våningars last.Efter dimensionering av väggarnas pelar-balksystem undersöktesfem leverantörers EPD:er i fas A1-A3 för massivväggar. GWPvärdetsom användes i studien är ett medelvärde från de olikaproducenterna. I resultatet presenteras utsläppet i kg CO2e från entraditionell innerskivas betong med tillhörande armering ochisolering kontra pelar-balksystem med ökad armering ochisolering. Resultatet påvisar att ett pelar-balksystem till och med 10våningars last ger en reduktion av växthusgaser. Därefter ökarklimatpåverkan jämfört mot traditionell innerskiva. För 5 våningarär reduktionen 8 procent och knappt 2 procent för 10 våningarslast. Slutsatsen är att pelar-balksystem är fördelaktigt att applicera iverkligheten om byggnaden inte överstiger 10 våningar.

Abstract [en]

In 2019, construction and the real estate sector accounted forapproximately 21 percent of Sweden´s total domestic greenhousegas emissions. Seen in an interval from 1993 until 2019, the totalemissions of greenhouse gases have decreased. This is because theemissions from heating have been reduced. If only the emissionsfrom renovation and construction are studied, the emissions haveincreased significantly during the same period. To break this trendof increased greenhouse gases during renovation and construction,it´s necessary for the construction and real estate sector to react anddevelop alternative solutions. An alternative to reducing emissionsis to dimension leaner constructions that require less material.Concrete structures constitutes a significant proportion ofgreenhouse gas emissions. The concrete industry´s poor startingpoint provides a strong initial position in improving futureconstructions. This study was carried out on behalf of AttacusStomsystem with the purpose of investigating how a column-beamsystem with thinners for load-bearing inner boards insandwichelements affect the direct emissions of greenhouse gases.The study investigated a fictitious sandwichelement. Thesandwichelement is exposed to loads from 5, 10, 15 and 20 floors.After dimension the column-beam system, the EPD of fivesuppliers in phase A1-A3 for solid walls was examined. The GWPvalue used in the study is an average value from the differentproducers. The result presents the emission in kg CO2e from theconcrete of a traditional inner boards with associatedreinforcement an insulation versus the column-beam system. Theresults show that at column-beam system up to and including aload of 10 storeys provides a reduction of greenhouse gases.Thereafter, the climate impact increases in line with the traditionalinner board. For 5 storeys, the reduction is 8 percent and just under2 percent for 10 storey loads. The conclusion is that column-beamsystem are advantageous to apply in reality if the building doesn´texceed 10 floors.

Place, publisher, year, edition, pages
2022. , p. 126
Keywords [en]
CO2e, column-beam system, dimensioning, emissions, thinning
Keywords [sv]
CO2e, dimensionering, förtunning, pelar-balksystem, utsläpp
National Category
Other Civil Engineering
Identifiers
URN: urn:nbn:se:miun:diva-48429OAI: oai:DiVA.org:miun-48429DiVA, id: diva2:1763722
Subject / course
Building Engineering BY1
Educational program
Building Engineering Sustainable Building TBYHG 180 higher education credits
Supervisors
Examiners
Note

2022-07-01

Available from: 2023-06-07 Created: 2023-06-07 Last updated: 2025-09-25

Open Access in DiVA

fulltext(29392 kB)84 downloads
File information
File name FULLTEXT01.pdfFile size 29392 kBChecksum SHA-512
f5b02f1a5b4790f59a3447cb619193e899b1e1388d7fed389b3cd89abdff0f9c5181e4796da6bd1a3d3e374cd92888bbeda169bfc6fdd0b30d01841d3864b853
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Olander, Maja
By organisation
Department of Ecotechnology and Suistainable Building Engineering
Other Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 85 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 156 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf