Validation of a 3D CT method for measurement of linear wear of acetabular cups: A hip simulator study
KTH, Fiber- och polymerteknologi.
KTH, Fiber- och polymerteknologi.ORCID iD: 0000-0002-5010-5391
New York University, Department of Radiology.
Loma Linda University, Orthopaedic Research Center.
Show others and affiliations
2011 (English)In: Acta Orthopaedica, ISSN 1745-3674, E-ISSN 1745-3682, Vol. 82, no 1, p. 35-41Article in journal (Refereed) Published
Abstract [en]

Material and methods Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip simulator. Before and after wear, they were (1) imaged with a CT scanner using a phantom model device, (2) measured using a coordinate measurement machine (CMM), and (3) weighed. CMM was used as the reference method for measurement of femoral head penetration into the cup and for comparison with CT, and gravimetric measurements were used as a reference for both CT and CMM. Femoral head penetration and wear vector angle were studied. The head diameters were also measured with both CMM and CT. The repeatability of the method proposed was evaluated with two repeated measurements using different positions of the phantom in the CT scanner. Results The accuracy of the 3D CT method for evaluation of linear wear was 0.51 mm and the repeatability was 0.39 mm. Repeatability for wear vector angle was 17 degrees A degrees. Interpretation This study of metal-meshed hip-simulated acetabular cups shows that CT has the capacity for reliable measurement of linear wear of acetabular cups at a clinically relevant level of accuracy.

Place, publisher, year, edition, pages
2011. Vol. 82, no 1, p. 35-41
Keywords [en]
Total Hip-Arthroplasty, Semiautomated Program, Component Migration, Computed-Tomography, Fusion, Repeatability, Penetration, Time
National Category
Surgery
Research subject
SRA - ICT
Identifiers
URN: urn:nbn:se:miun:diva-46896DOI: 10.3109/17453674.2011.552777ISI: 000287025400006PubMedID: 21281259Scopus ID: 2-s2.0-79751483254OAI: oai:DiVA.org:miun-46896DiVA, id: diva2:1729291
Note

QC 20110321

Available from: 2011-03-21 Created: 2023-01-20 Last updated: 2025-09-25Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Maguire Jr., Gerald Q.

Search in DiVA

By author/editor
Nilsson, FritjofGedde, Ulf W.Maguire Jr., Gerald Q.
In the same journal
Acta Orthopaedica
Surgery

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 51 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf