Utvärdering av Industrial Internet of Things med Industrial Ethernet: En implementering av Profinet-system för detektering av responstiden
Mid Sweden University, Faculty of Science, Technology and Media, Department of Information Systems and Technology.
2022 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Framväxten av antalet smarta enheter som är integrerade med Internet har lett till att behovet av Internet-of-Things ökar i olika tillämpningar, nämligen inom industrier fabrikstillverkning. Projektets huvudsakliga syfte är att implementera ett styrsystem med hjälp av Industrial Ethernet och användningen av Profinet protokoll som användargränssnitt. Denna studies huvudsakliga uppgift är undersöka prestandan av detta system och vilken skalbarhet man kan få ut ur den, dessutom utföra olika typer av tester för att mäta responstiden hos detta system med hjälp av real-time system. Studien lyfter upp IIoT funktionalitet, dess featureprogram och möjligheten att den implementeras på bred tillgänglig hårdvara. Det slutliga resultatet av tidmätningarna kunde i genomsnitt visa hur lång tid det tar för en signal att skickas inom ett Profinet-Nätverk. Mer speciellt, så tar en signal i genomsnitt 0,97ms. , vilket är relevant kort tid i förhållande till projektanpassningar inom industrier. Den beräknade standardavvikelsen visar på de erhållna värdenas noggrannhet, då den visade hur utspridda värdena är och hur mycket håller de sig till de beräknade medelvärdena. Utförande av Stresstesten bidrog till att dra slutsatser om systemets prestanda. Då de olika medelvärdena visade hur antalet signaler skiljer sig i förhållande till Cykel-tidsändringen. Resultatet av denna test visade också maximala antalet paket/signaler som kan skickas inom en begränsad tid. Dessutom presenterade resultatet gränsvärdet av det minimala antalet signaler som kan skickas oavsett hur mycket Cykel-tiden ökas eller minskas. Mer specifikt, visade detta system att det kan skicka 3250 signal inom en begränsad tid (60 s) vid Cykel-tid (1), och det kan skicka minst 1500 signaler inom samma begränsade tid. Det slutliga resultatet förslog ett par framtida arbete, det första var att utföra ett Profinet-system med hjälp av trådlösa fältbussar, och jämföra det med denna studies resultat för mer pålitlig implementation. Den andra var utreda säkerhet och krypteringen av Industrial Ethernet, detta skulle ge oss en bild om hur säkert att adoptera denna teknik.

Abstract [en]

The growth of the number of smart devices that are integrated into the Internet has led to an increase in the need for Internet-of-Things in various applications, namely in industries and manufacturing plants. The main purpose of the project is to implement a control system using Industrial Ethernet with the use of Profinet protocol as a user interface. This study will mainly examine the performance of this system and what scalability can be obtained from it, in addition to, performing various types of tests to measure the response time of this system by using real-time systems. The study highlights IIoT functionality, its feature program and the possibility that it is implemented on readily available hardware. The final results of time measurements could show on average how long a signal takes to be sent within a Profinet Network. More specifically, a signal takes an average of 0.97ms. The calculated standard deviation indicates the accuracy of the values obtained, as it showed that they scattered to the calculated mean values. Performing the Stress Test helped to draw conclusions about the performance of the system. These calculated different averages showed how the number of signals differs in relation to the Cycle time change. The result of this test also showed the maximum number of packets / signals that can be sent within a limited time. In addition, the result presented the limit values of the minimum number of signals that can be sent regardless of how much the “Cycle Clock” is increased or decreased. More specifically, this system showed that it can send 3250 signals within a limited time 60 (s) at Cycle time 1, and it can send at least 1500 signals within the same limited time. The final result suggested a couple of future work, the first was to perform a Profinet system by using wireless fieldbuses and compare it with the results of this study for more reliable implementation. The second was to investigate the security and encryption of Industrial Ethernet, this would give us an idea of how secure to adopt this technology.

Place, publisher, year, edition, pages
2022. , p. 47
Keywords [sv]
IoT, IIoT, Profinet, Industrial Ethernet
National Category
Software Engineering
Identifiers
URN: urn:nbn:se:miun:diva-45351Local ID: DT-V22-G3-014OAI: oai:DiVA.org:miun-45351DiVA, id: diva2:1676606
Subject / course
Computer Engineering DT1
Educational program
Master of Science in Engineering - Computer Engineering TDTEA 300 higher education credits
Supervisors
Examiners
Available from: 2022-06-27 Created: 2022-06-27 Last updated: 2025-09-25Bibliographically approved

Open Access in DiVA

fulltext(1003 kB)149 downloads
File information
File name FULLTEXT01.pdfFile size 1003 kBChecksum SHA-512
e965ee84f4b3e68282192671c756d12cd781ae35677c64a976f38f3056cbe92c798839dbc1396fee980b6870d8a4d906464b089f3da2163c526e0eb5926abf02
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Lazkin, Youssuf
By organisation
Department of Information Systems and Technology
Software Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 150 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 209 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf