Mid Sweden University

miun.sePublications
Planned maintenance
A system upgrade is planned for 17/11-2026, at 12:00-13:00. During this time DiVA will be unavailable.
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Spectroscopic and Microscopic X-ray Fluorescence Analysis for Environmental and Industrial Applications
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design. (Radiation Sensing and Imaging Systems)
2022 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Heavy metals are well-known environmental pollutants due to its potential impact on associated ecosystems and human health. Thus, it is important to monitor the levels of heavy metals in the environment. X-ray fluorescence (XRF) analysis is a powerful and effective screening tool in measuring the concentration of multi-elements simultaneously.

This thesis provides insight into development and implementation of XRF instruments for environmental monitoring and industrial process control. The XRF method was compared with a commercial scanning electron microscope with energy dispersive spectroscopy (SEM-EDS) for fly ash samples. Qualitative analysis and semi-quantitative analysis of Na, S, Cl, K and Cd in incineration fly ash were performed with these two similar techniques. One of the challenges of using XRF is the scattering background noise from the primary beam, which decreases the detection limit and the sensitivity of the measurement system. Hence, an X-ray beam filter was chosen to suppress the background noise for a specific element, Cr, in leachate. Numerical simulations and experiments were developed to find the proper filter material and thickness by calculating the X-ray fluorescence intensities and the signal-to-noise ratio. The developed system is capable of online monitoring of Cr levels, to certify that the concentration is below the threshold level in leachate. An XRF prototype was built and calibrated for underwater Hg analysis in maritime wet sediment using a radioisotope source. The presented results show that it is possible to detect Hg by K-shell emission thus enabling XRF analysis for sediment underwater.

For non-homogeneous samples, an image revealing the elemental distribution can be achieved by micro-XRF (µ-XRF). XRF mapping of element distributions on a microscopic level was obtained by using scanning XRF microscopy and full-field XRF projection microscopy (FF-XRF). The spatial resolution of the scanning XRF imaging setup using an X-ray tube is in the order of 100 µm, but need to be further improved to measure the homogeneity of S on individual fiber level in pulp and paper industry. For the scanning technique, it is a tradeoff between resolution and measurement time. Another technique is FF-XRF imaging, and a setup was implemented using an energy resolving pixel detector and X-ray optics. The capabilities and limitations of using X-ray optics in XRF imaging systems have been identified. These microscopy measurements can guide further comprehensive environmental and industrial monitoring missions, utilizing elemental distribution information.

Place, publisher, year, edition, pages
Mid Sweden University , 2022. , p. 47
Series
Mid Sweden University doctoral thesis, ISSN 1652-893X ; 371
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:miun:diva-45007ISBN: 978-91-89341-66-1 (print)OAI: oai:DiVA.org:miun-45007DiVA, id: diva2:1658948
Public defence
2022-06-17, C312, Holmgatan 10, Sundsvall, Västernorrland, 13:00 (English)
Opponent
Supervisors
Note

At the time of the defence the following papers were unpublished: paper 3 (accepted), paper 4 (in manuscript), paper 6 (in manuscript).

Available from: 2022-05-18 Created: 2022-05-18 Last updated: 2025-09-25Bibliographically approved
List of papers
1. Comparison of Elemental Analysis Techniques for Fly Ash from Municipal Solid Waste Incineration using X-rays and Electron Beams
Open this publication in new window or tab >>Comparison of Elemental Analysis Techniques for Fly Ash from Municipal Solid Waste Incineration using X-rays and Electron Beams
2019 (English)In: IOP Conference Series: Earth and Environmental Science, Institute of Physics (IOP), 2019, Vol. 337, no 1, article id 012007Conference paper, Published paper (Refereed)
Abstract [en]

With the rapid expansion of the waste incineration business both in Europe and globally, there is a growing need for the elemental analysis for fly ash from municipal solid waste incineration. In this work, samples of washed and unwashed ash from municipal solid waste incineration in Sundsvall are evaluated. Qualitative analysis and semi-quantitative analysis are used to compare two elemental analysis methods, scanning electron microscope with energy dispersive spectroscopy (SEM-EDS) and X-ray fluorescence (XRF) measurement. Both methods are used to retrieve the difference in elemental composition between washed and unwashed fly ash. SEM-EDS accurately detects light elements from well-prepared samples in a vacuum environment, while, for online measurements, XRF is a potential method that analyses hazardous metal content in the fly ash. 

Place, publisher, year, edition, pages
Institute of Physics (IOP), 2019
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:miun:diva-38235 (URN)10.1088/1755-1315/337/1/012007 (DOI)000587908200007 ()2-s2.0-85076187399 (Scopus ID)
Conference
International Scientific Conference on Efficient Waste Treatment 2018, EWT 2018, St. Petersburg, Russian Federation, 13 December 2018 through 14 December 2018
Available from: 2020-01-15 Created: 2020-01-15 Last updated: 2025-09-25Bibliographically approved
2. Signal-to-Noise Ratio Optimization in X-ray Fluorescence Spectrometry for Chromium Contamination Analysis
Open this publication in new window or tab >>Signal-to-Noise Ratio Optimization in X-ray Fluorescence Spectrometry for Chromium Contamination Analysis
Show others...
2021 (English)In: Talanta: The International Journal of Pure and Applied Analytical Chemistry, ISSN 0039-9140, E-ISSN 1873-3573, Vol. 230, article id 122236Article in journal (Refereed) Published
Abstract [en]

In most cases, direct X-ray fluorescence (XRF) analysis of solutions entails technical difficulties due to a high X-ray scattering background resulting in a spectrum with a poor signal-to-noise ratio (SNR). Key factors that determine the sensitivity of the method are the energy resolution of the detector and the amount of scattered radiation in the energy range of interest. Limiting the width of the primary spectrum by the use of secondary targets, or filters, can greatly improve the sensitivity for specific portions of the spectrum. This paper demonstrates a potential method for SNR optimization in direct XRF analysis of chromium (Cr) contamination. The suggested method requires minimal sample preparation and achieves higher sensitivity compared to existing direct XRF analysis. Two states of samples, fly ash and leachate from municipal solid waste incineration, were investigated. The effects of filter material, its absorption edge and filter thickness were analyzed using the combination of Monte Carlo N-Particle (MCNP) code and energy-dispersive XRF spectrometry. The applied filter removes primary photons with energies interfering with fluorescence photons from the element of interest, thus results in lower background scattering in the spectrum. The SNR of Cr peak increases with filter thickness and reaches a saturation value when further increased thickness only increases the measurement time. Measurements and simulations show that a Cu filter with a thickness between 100 μm and 140 μm is optimal for detecting Cr by taking into account both the SNR and the exposure time. With direct XRF analysis for solutions, the limit of quantitation (LOQ) of the achieved system was 0.32 mg/L for Cr, which is well below the allowed standard limitation for landfills in Sweden. This work shows that XRF can gain enough sensitivity for direct monitoring to certify that the Cr content in leachate is below environmental limits.

Keywords
Chromium, Environmental monitoring, Hazardous materials, Limit of quantitation (LOQ), Waste management, X-ray fluorescence analysis (XRF)
National Category
Analytical Chemistry Environmental Management
Identifiers
urn:nbn:se:miun:diva-39934 (URN)10.1016/j.talanta.2021.122236 (DOI)000657143300001 ()33934759 (PubMedID)2-s2.0-85103402317 (Scopus ID)
Available from: 2021-03-31 Created: 2020-09-21 Last updated: 2025-09-25Bibliographically approved
3. Geometrical influence on Hg determination in wet sediment using K-shell fluorescence analysis
Open this publication in new window or tab >>Geometrical influence on Hg determination in wet sediment using K-shell fluorescence analysis
Show others...
2023 (English)In: X-Ray Spectrometry, ISSN 0049-8246, E-ISSN 1097-4539, Vol. 52, no 4, p. 182-196Article in journal (Refereed) Published
Abstract [en]

 To quickly identify maritime sites polluted by heavy metal contaminants, reductions in the size of instrumentation have made it possible to bring an X-ray fluorescence (XRF) analyzer into the field and in direct contact with various samples. The choice of source-sample-detector geometry plays an important role in minimizing the Compton scattering noise and achieving a better signal-to-noise ratio (SNR) in XRF measurement conditions, especially for analysis of wet sediments. This paper presents the influence of geometrical factors on a prototype, designed for in situ XRF analysis of mercury (Hg) in wet sediments using a 57Co excitation source and an X-ray spectrometer. The unique XRF penetrometer prototype has been constructed and tested for maritime wet sediment. The influence on detection efficiency and SNR of various geometrical arrangements have been investigated using the combination of Monte Carlo simulations and laboratory experiments. Instrument calibration was performed for Hg analysis by means of prepared wet sediments with the XRF prototype. The presented results show that it is possible to detect Hg by K-shell emission, thus enabling XRF analysis for underwater sediments. Consequently, the XRF prototype has the potential to be applied as an environmental screening tool for analysis of polluted sediments with relatively high concentrations (e.g., >2880 ppm for Hg), which would benefit in situ monitoring of maritime pollution caused by heavy metals.

Place, publisher, year, edition, pages
John Wiley & Sons, 2023
Keywords
environmental analysis, geometrical influence, in situ, mercury contamination, portable XRF
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:miun:diva-44957 (URN)10.1002/xrs.3303 (DOI)000821390100001 ()2-s2.0-85133523711 (Scopus ID)
Conference
EXSA 2021, 1st virtual conference in X-ray spectrometry, [DIGITAL], June 21-24, 2022.
Available from: 2022-07-07 Created: 2022-05-06 Last updated: 2025-09-25
4. On-Site X-ray Fluorescence Spectrometry Measurement Strategy for Assessing the Sulfonation to Improve Chemimechanical Pulping Processes
Open this publication in new window or tab >>On-Site X-ray Fluorescence Spectrometry Measurement Strategy for Assessing the Sulfonation to Improve Chemimechanical Pulping Processes
Show others...
2022 (English)In: ACS Omega, E-ISSN 2470-1343, Vol. 7, no 51, p. 48555-48563Article in journal (Refereed) Published
Abstract [en]

Minimizing the fiber property distribution would have the potential to improve the pulp properties and the process efficiency of chemimechanical pulp. To achieve this, it is essential to improve the level of knowledge of how evenly distributed the sulfonate concentration is between the individual chemimechanical pulp fibers. Due to the variation in quality between pulpwood and sawmill chips, as well as the on-chip screening method, it is difficult to develop an impregnation system that ensures the even distribution of sodium sulfite (Na2SO3) impregnation liquid. It is, therefore, crucial to measure the distribution of sulfonate groups within wood chips and fibers on a microscale. Typically, the degree of unevenness, i.e., the amount of fiber sulfonation and softening prior to defibration, is unknown on a microlevel due to excessively robust or complex processing methods. The degree of sulfonation at the fiber level can be determined by measuring the distribution of elemental sulfur and counterions of sulfonate groups, such as sodium or calcium. A miniaturized energy-dispersive X-ray fluorescence (ED-XRF) method has been developed to address this issue, enabling the analysis of sulfur distributions. It is effective enough to be applied to industrial laboratories for further development, i.e., improved image resolution and measurement time. 

National Category
Paper, Pulp and Fiber Technology
Identifiers
urn:nbn:se:miun:diva-46771 (URN)10.1021/acsomega.2c07086 (DOI)000903289800001 ()2-s2.0-85144530016 (Scopus ID)
Available from: 2023-01-09 Created: 2023-01-09 Last updated: 2025-09-25Bibliographically approved
5. Full-field X-ray fluorescence imaging with a straight polycapillary X-ray collimator
Open this publication in new window or tab >>Full-field X-ray fluorescence imaging with a straight polycapillary X-ray collimator
2020 (English)In: Journal of Instrumentation, E-ISSN 1748-0221, Vol. 15, no 12, article id P12033Article in journal (Refereed) Published
Abstract [en]

Due to the availability of X-ray imaging detectors, full-field X-ray fluorescence (FF-XRF) imaging technique has become achievable, which provides an alternative to scanning X-ray fluorescence imaging with a micro-focus X-ray beamline. In this paper, we present a setup based on straight capillary optics and an energy-dispersive hybrid pixel detector, which can perform simultaneous mapping of several chemical elements. The photon transmission efficiency and spatial resolution are compared between two X-ray collimation setups: one using pinhole optics and one using straight polycapillary optics. There is a tradeoff between the spatial resolution and transmission efficiency when considering X-ray optics. When optimizing the spatial resolution, using straight capillary optics achieved a higher intensity gain when comparing with the pinhole setup. Characterization of the polycapillary imaging setup is performed through analyzing various samples in order to investigate the spatial frequency response and the energy sensitivity. This developed setup is capable of FF-XRF imaging in characteristic energies below 20 keV, while for higher energies the spatial resolution is affected by photon transmission through the collimator. This work shows the potential of the FF-XRF instrument in the monitoring of toxic metal distributions in environmental mapping measurements.

Keywords
Inspection with x-rays, X-ray fluorescence (XRF) systems, Hybrid detectors, X-ray transport and focusing
National Category
Atom and Molecular Physics and Optics Environmental Sciences
Identifiers
urn:nbn:se:miun:diva-39936 (URN)10.1088/1748-0221/15/12/P12033 (DOI)000608265500026 ()2-s2.0-85099099203 (Scopus ID)
Available from: 2020-12-29 Created: 2020-09-21 Last updated: 2025-09-25Bibliographically approved
6. Characterization of micro pore optics for full-field X-ray fluorescence imaging
Open this publication in new window or tab >>Characterization of micro pore optics for full-field X-ray fluorescence imaging
Show others...
2023 (English)In: Journal of Instrumentation, E-ISSN 1748-0221, Vol. 18, no 01, article id C01017Article in journal (Refereed) Published
Abstract [en]

Elemental mapping images can be achieved through step scanning imaging using pinholeopticsor microporeoptics(MPO),oralternativelybyfull-field X-ray fluorescenceimaging (FF-XRF). X-ray optics for FF-XRF canbe manufacturedwith different micro-channelgeometries such as square, hexagonal or circular channels. Each optic geometry creates different imaging artefacts. Square-channel MPOs generate a high intensity central spot due to two reflections via orthogonal channel walls inside a single channel, which is the desirable part for image formation, and two perpendicular lines forming a cross due to reflections in one plane only. Thus, we have studied the performance of a square-channel MPO in an FF-XRF imaging system. The setup consists of a commercially available MPO provided by Photonis and a Timepix3 readout chip with a silicon detector. Imaging of fluorescence from small metal particles has been used to obtain the point spreadfunction(PSF) characteristics. The transmissionthroughMPO channelsand variation of the critical reflection angle are characterized by measurements of fluorescence from copper and titanium metal fragments. Since the critical angle of reflection is energy dependent, the cross-arm artefacts will affect the resolution differently for different fluorescence energies. It is possible to identify metal fragments due to the form of the PSF function. The PSF function can be further characterized using a Fourier transform to suppress diffuse background signals in the image.

Keywords
X-ray fluorescence (XRF) systems; Scintillators and scintillating fibres and light guides; Spectrometers; X-ray transport and focusing
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:miun:diva-44958 (URN)10.1088/1748-0221/18/01/C01017 (DOI)000926596900001 ()2-s2.0-85146494710 (Scopus ID)
Conference
23nd International Workshop on Radiation Imaging Detectors 26–30 June 2022
Projects
ImSpec - Multiple energy band imaging spectroscopy for material and object classification
Funder
Knowledge Foundation
Available from: 2023-01-18 Created: 2022-05-06 Last updated: 2025-09-25Bibliographically approved

Open Access in DiVA

fulltext(1819 kB)1431 downloads
File information
File name FULLTEXT01.pdfFile size 1819 kBChecksum SHA-512
0fd08a13c35f6851ad06e32d670a9d929c28016c33cdb6b2d948fb92e4f061cf21530d5153c4dfdd3c8d4e787ea6f12f8591b06a462ee39ccf4d8068218d40bb
Type fulltextMimetype application/pdf

Authority records

An, Siwen

Search in DiVA

By author/editor
An, Siwen
By organisation
Department of Electronics Design
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 1442 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 1197 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf