Mid Sweden University

miun.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Geometrical influence on Hg determination in wet sediment using K-shell fluorescence analysis
Mid Sweden University, Faculty of Science, Technology and Media, Department of Computer and Electrical Engineering (2023-).ORCID iD: 0000-0002-4196-6296
Mid Sweden University, Faculty of Science, Technology and Media, Department of Computer and Electrical Engineering (2023-).ORCID iD: 0000-0002-5619-409X
Mid Sweden University, Faculty of Science, Technology and Media, Department of Computer and Electrical Engineering (2023-).
RISE, Sundsvall, Sweden.
Show others and affiliations
2023 (English)In: X-Ray Spectrometry, ISSN 0049-8246, E-ISSN 1097-4539, Vol. 52, no 4, p. 182-196Article in journal (Refereed) Published
Abstract [en]

 To quickly identify maritime sites polluted by heavy metal contaminants, reductions in the size of instrumentation have made it possible to bring an X-ray fluorescence (XRF) analyzer into the field and in direct contact with various samples. The choice of source-sample-detector geometry plays an important role in minimizing the Compton scattering noise and achieving a better signal-to-noise ratio (SNR) in XRF measurement conditions, especially for analysis of wet sediments. This paper presents the influence of geometrical factors on a prototype, designed for in situ XRF analysis of mercury (Hg) in wet sediments using a 57Co excitation source and an X-ray spectrometer. The unique XRF penetrometer prototype has been constructed and tested for maritime wet sediment. The influence on detection efficiency and SNR of various geometrical arrangements have been investigated using the combination of Monte Carlo simulations and laboratory experiments. Instrument calibration was performed for Hg analysis by means of prepared wet sediments with the XRF prototype. The presented results show that it is possible to detect Hg by K-shell emission, thus enabling XRF analysis for underwater sediments. Consequently, the XRF prototype has the potential to be applied as an environmental screening tool for analysis of polluted sediments with relatively high concentrations (e.g., >2880 ppm for Hg), which would benefit in situ monitoring of maritime pollution caused by heavy metals.

Place, publisher, year, edition, pages
John Wiley & Sons, 2023. Vol. 52, no 4, p. 182-196
Keywords [en]
environmental analysis, geometrical influence, in situ, mercury contamination, portable XRF
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:miun:diva-44957DOI: 10.1002/xrs.3303ISI: 000821390100001Scopus ID: 2-s2.0-85133523711OAI: oai:DiVA.org:miun-44957DiVA, id: diva2:1656517
Conference
EXSA 2021, 1st virtual conference in X-ray spectrometry, [DIGITAL], June 21-24, 2022.
Available from: 2022-07-07 Created: 2022-05-06 Last updated: 2025-09-25
In thesis
1. Spectroscopic and Microscopic X-ray Fluorescence Analysis for Environmental and Industrial Applications
Open this publication in new window or tab >>Spectroscopic and Microscopic X-ray Fluorescence Analysis for Environmental and Industrial Applications
2022 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Heavy metals are well-known environmental pollutants due to its potential impact on associated ecosystems and human health. Thus, it is important to monitor the levels of heavy metals in the environment. X-ray fluorescence (XRF) analysis is a powerful and effective screening tool in measuring the concentration of multi-elements simultaneously.

This thesis provides insight into development and implementation of XRF instruments for environmental monitoring and industrial process control. The XRF method was compared with a commercial scanning electron microscope with energy dispersive spectroscopy (SEM-EDS) for fly ash samples. Qualitative analysis and semi-quantitative analysis of Na, S, Cl, K and Cd in incineration fly ash were performed with these two similar techniques. One of the challenges of using XRF is the scattering background noise from the primary beam, which decreases the detection limit and the sensitivity of the measurement system. Hence, an X-ray beam filter was chosen to suppress the background noise for a specific element, Cr, in leachate. Numerical simulations and experiments were developed to find the proper filter material and thickness by calculating the X-ray fluorescence intensities and the signal-to-noise ratio. The developed system is capable of online monitoring of Cr levels, to certify that the concentration is below the threshold level in leachate. An XRF prototype was built and calibrated for underwater Hg analysis in maritime wet sediment using a radioisotope source. The presented results show that it is possible to detect Hg by K-shell emission thus enabling XRF analysis for sediment underwater.

For non-homogeneous samples, an image revealing the elemental distribution can be achieved by micro-XRF (µ-XRF). XRF mapping of element distributions on a microscopic level was obtained by using scanning XRF microscopy and full-field XRF projection microscopy (FF-XRF). The spatial resolution of the scanning XRF imaging setup using an X-ray tube is in the order of 100 µm, but need to be further improved to measure the homogeneity of S on individual fiber level in pulp and paper industry. For the scanning technique, it is a tradeoff between resolution and measurement time. Another technique is FF-XRF imaging, and a setup was implemented using an energy resolving pixel detector and X-ray optics. The capabilities and limitations of using X-ray optics in XRF imaging systems have been identified. These microscopy measurements can guide further comprehensive environmental and industrial monitoring missions, utilizing elemental distribution information.

Place, publisher, year, edition, pages
Mid Sweden University, 2022. p. 47
Series
Mid Sweden University doctoral thesis, ISSN 1652-893X ; 371
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:miun:diva-45007 (URN)978-91-89341-66-1 (ISBN)
Public defence
2022-06-17, C312, Holmgatan 10, Sundsvall, Västernorrland, 13:00 (English)
Opponent
Supervisors
Note

At the time of the defence the following papers were unpublished: paper 3 (accepted), paper 4 (in manuscript), paper 6 (in manuscript).

Available from: 2022-05-18 Created: 2022-05-18 Last updated: 2025-09-25Bibliographically approved

Open Access in DiVA

fulltext(2999 kB)696 downloads
File information
File name FULLTEXT01.pdfFile size 2999 kBChecksum SHA-512
7670214a50788819ace2ca8c333de957eacb8dd1200ecfee9662a813d6bd69e533e4940a68e726b861b20f10c9d2034845a4f992f0e3d0c7fd84cf78a6bd3dc2
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Authority records

An, SiwenKrapohl, DavidNorlin, BörjeThungström, Göran

Search in DiVA

By author/editor
An, SiwenKrapohl, DavidGonzález, CharlotteNorlin, BörjeThungström, Göran
By organisation
Department of Computer and Electrical Engineering (2023-)Department of Engineering, Mathematics, and Science Education (2023-)
In the same journal
X-Ray Spectrometry
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 696 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 784 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf