Karatärisering av XRF-mätning med 120kV röntgenrör
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.
2021 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Syftet med denna undersökning är att utvärdera en XRFmätuppställning som använder högre spänning påröntgenröret än konventionella XRF-instrument. Iutvärderingen uppskattas Limit Of Detection (LOD) påtungmetaller genom att använda XRF-metoden, där dettestades olika filter, vinklar och rörspänning och derasinverkan på provet.Metaller med hög densitet kallas för tungmetaller. Vissatungmetaller är livsnödiga men vissa är skadliga för bådemänniskor och naturen. Några exempel på dessa tungmetallerär kvicksilver, kadmium och bly, vilka är farliga grundämnensom människor kan få i sig via föda.Vid utförande av denna undersökning användes enröntgenkälla (30-120keV) som var kopplad till mjukvaransom skickade fotonenergi och ström. En spektrometer med CdTe-detektor användes för att mäta energin på fotonerna från provet. Detektorn var kopplad till mjukvara där det uppmätt spektra kunde observeras och energitopparnas intensitet kunde avläsas. Topparnas intensitet kan härledas tillprovets samansättning. Sedan uppskattades LOD förproverna. Den teknik som jag har studerat ger möjlighet till bättre mätresultat än konventionella XRFutrustningar. Detta eftersom högre rörspänning gör att K-linjerna, inte bara L-linjerna, för tungmetaller kan avläsas

Place, publisher, year, edition, pages
2021. , p. 29
Keywords [en]
XRF, X-ray source, 123CdTe detector, spectrometer, heavy metals, intensity, K-lines, L-lines, and limit of detection (LOD).
Keywords [sv]
XRF, Röntgenkälla, 123CdTe-detektor, spektrometer, tungmetaller, intensitet, K-linjerna, L-linjerna och limit of detection (LOD).
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:miun:diva-42590Local ID: ET-V21-G3-061OAI: oai:DiVA.org:miun-42590DiVA, id: diva2:1578247
Subject / course
Electrical Engineering ET2
Educational program
Civilingenjör i elektroteknik TELTA 300 hp
Supervisors
Examiners
Available from: 2021-07-06 Created: 2021-07-06 Last updated: 2025-09-25Bibliographically approved

Open Access in DiVA

fulltext(1371 kB)297 downloads
File information
File name FULLTEXT01.pdfFile size 1371 kBChecksum SHA-512
24dd54fd21cfb779ba831b5b28c549c775929b0f48e59b30a19f7aa95219413520a1b5f8d0205e4e8dc10be93c1d433d39213f99d399f90456fc15e75a94b231
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Mahmood, Rahimi
By organisation
Department of Electronics Design
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 298 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 381 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf