Mid Sweden University

miun.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Framtidssäkra produktionen: Implementera ny teknik i äldre styrutrustning
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.
2021 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Målsättningen med rapporten är att bestämma på vilket sätt det går att hantera problem med gamla komponenter som går sönder på produktionslinjen som behöver ersättas med modernare utrustning. Att analysera valet till metod och val av passande ersättande komponenter, då valet kan vara kritisk för anläggningens funktion. Att jämföra de kommunikationsgränssnitt som används i arbetet i from av överföringshastigheter, distanser och funktion. Arbetet går igenom kommunikationsgränssnitt som PROFINET, RS-232, HART, Siemens protokollet RK 512 och proceduren 3964R. Hur signalöverföring med Current Loop fungerar. Arbetet visar hur det är möjligt att återfinna gamla data från produkter som installerats decennier tidigare genom litteraturstudie och mångsidig testning. Beroende på vilken situationen är i industrin och planer för framtida maskinuppgraderingar kan lösningsmetoden variera för att framtidssäkra produktionen med ny teknik eller med nya komponenter.  Resultatet av arbetet gav åter igen en fungerande produktionslinje. Kommunikationsgränssnitt som PROFINET är superiör med snabb överföringshastighet, långt kabelavstånd och skydd mot EMC. Vilket gör den till ett framtidssäkert gränssnitt. Till skillnad från äldre gränsnitt som den väletablerade RS232 som har långsam dataöverföring, korta kabelavstånd och är känslig för EMC. HART är ett flexibelt kommunikationsgränssnitt som använder Current Loop för signalöverföring. Eftersom gränssnittet använder ström möjliggör det mycket långa kabelavstånd och skydd mot EMC, men långsam datahastighet. 

Abstract [en]

The aim of the report is to determine how to deal with problems with old components that break on the production line that need to be replaced with modern equipment. To analyse the choice of method and choice of suitable replacement components, as the choice can be critical for the plant's function. To compare the communication interfaces used in the work in the form of transmission speeds, distances, and function.

The work goes through communication interface such as PROFINET, RS-232, HART, the Siemens protocol RK 512 and the procedure 3964R. How signal transmission with Current Loop works. The work shows how it is possible to find old data from products that were installed decades earlier through literature study and versatile testing. Depending on the situation in the industry and plans for future machine upgrades, the solution method can vary, as you want to secure the future of production with new technology or with new components. The result of the work once again gave a functioning production line. Communication interfaces such as PROFINET are superior with fast transmission speeds, long cable distances and protection against EMC. Which makes it a future-proof interface. Unlike older interfaces such as the well-established RS232 which has slow data transfer, short cable distances and is sensitive to EMC. HART is a flexible communication interface that uses the Current Loop for signal transmission. Because the interface uses current, it provides very long cable distances and protection against EMC, but slow data speeds.

Place, publisher, year, edition, pages
2021. , p. 71
Keywords [sv]
Framtidssäker, PLC, Skanner, Datakommunikation, Kommunikationsgränssnitt, Kommunikationsprotokoll, Current Loop, RS232, PROFINET, HART
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:miun:diva-42585OAI: oai:DiVA.org:miun-42585DiVA, id: diva2:1578109
Subject / course
Electrical Engineering ET2
Educational program
Automationsingenjör TAUMG 180 GR
Supervisors
Examiners
Available from: 2021-07-05 Created: 2021-07-05 Last updated: 2025-09-25Bibliographically approved

Open Access in DiVA

fulltext(3598 kB)301 downloads
File information
File name FULLTEXT01.pdfFile size 3598 kBChecksum SHA-512
2024b388bbc8c7ce668d9fec76c99e9e74871c037486e32c0f5edb34252436063d794038425b3404a47b440fd00e3bc5bc14d9a8a40bb7fc16a0b94d7a5d1e8d
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Olson, Kevin
By organisation
Department of Electronics Design
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 303 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 187 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf