Karaktärisering av spatial upplösning i röntgenmikroskopi
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.
2021 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

X-ray imaging was a very important detection that is used in many useful functionalities as in healthcare. It would be powerful and facilitate several functions if we could come up with a method that gives a better resolution when doing X-ray imaging. This will be done by using two different detectors, a commercial detector (Innocare) and a direct converting detector (Medipix3). These two detectors have different properties. In addition to these detectors, a radiation source that radiates with X-rays has been used and a line mask that provides the ability to read the resolution of the image. The use of these detectors will provide answers to the investigation of limitations that its detectors have.

Abstract [sv]

Röntgenavbildning är en viktig upptäckt som används i bland annat vården. Det skulle underlätta flera användningsområden om en metod kunde tas fram som ger bättre upplösning på bilder vid avbildning. I detta arbete undersöks vad som kan bidra till att få den bästa upplösningen vid röntgenavbildning. I undersökningen kommer det att användas två olika detektorer, en kommersiell detektor (Innocare) och en direktkonverterande detektor (Medipix3). Dessa två detektorer har olika egenskaper. Utöver dessa detektorer har en strålkälla som strålar med röntgenstrålar använts och en linjemask som ger möjligheten att läsa av bildens upplösning. Användningen av dessa detektorer kommer att ge svar på utredningen av begränsningar som dess detektorer har.

Place, publisher, year, edition, pages
2021. , p. 41
Keywords [sv]
Spatial upplösning, fokalpunkt, Medipix3, Innocare, röntgenmikroskop, karaktärisering, elektroteknik
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:miun:diva-42387Local ID: ET-V21-G3-059OAI: oai:DiVA.org:miun-42387DiVA, id: diva2:1573873
Subject / course
Electrical Engineering ET2
Educational program
Civilingenjör i elektroteknik TELTA 300 hp
Supervisors
Examiners
Available from: 2021-06-28 Created: 2021-06-28 Last updated: 2025-09-25Bibliographically approved

Open Access in DiVA

fulltext(1622 kB)188 downloads
File information
File name FULLTEXT01.pdfFile size 1622 kBChecksum SHA-512
1f05295f1fdcdc640643323f8768b51f4666ce453f117f1bd3ffcc6cd1f0686e275319d9e6d83aea680e566c2b624b61daab83a9c626b68bfdd0d3537b453a69
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Jabar, Alia
By organisation
Department of Electronics Design
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 190 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 349 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf