Mid Sweden University

miun.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
First Evaluation of a Newly Constructed Underwater Pulse Oximeter for Use in Breath-Holding Activities
Mid Sweden University, Faculty of Human Sciences, Department of Health Sciences.
Mid Sweden University, Faculty of Human Sciences, Department of Health Sciences.
Mid Sweden University, Faculty of Human Sciences, Department of Health Sciences.
2021 (English)In: Frontiers in Physiology, E-ISSN 1664-042X, Vol. 12, article id 649674Article in journal (Refereed) Published
Abstract [en]

Studying risk factors in freediving, such as hypoxic blackout, requires development of new methods to enable remote underwater monitoring of physiological variables. We aimed to construct and evaluate a new water- and pressure proof pulse oximeter for use in freediving research. The study consisted of three parts: (I) A submersible pulse oximeter (SUB) was developed on a ruggedized platform for recording of physiological parameters in challenging environments. Two MAX30102 sensors were used to record plethysmograms, and included red and infra-red emitters, diode drivers, photodiode, photodiode amplifier, analog to digital converter, and controller. (II) We equipped 20 volunteers with two transmission pulse oximeters (TPULS) and SUB to the fingers. Arterial oxygen saturation (SpO(2)) and heart rate (HR) were recorded, while breathing room air (21% O-2) and subsequently a hypoxic gas (10.7% O-2) at rest in dry conditions. Bland-Altman analysis was used to evaluate bias and precision of SUB relative to SpO(2) values from TPULS. (III) Six freedivers were monitored with one TPULS and SUB placed at the forehead, during a maximal effort immersed static apnea. For dry baseline measurements (n = 20), SpO(2) bias ranged between -0.8 and -0.6%, precision between 1.0 and 1.5%; HR bias ranged between 1.1 and 1.0 bpm, precision between 1.4 and 1.9 bpm. For the hypoxic episode, SpO(2) bias ranged between -2.5 and -3.6%, precision between 3.6 and 3.7%; HR bias ranged between 1.4 and 1.9 bpm, precision between 2.0 and 2.1 bpm. Freedivers (n = 6) performed an apnea of 184 +/- 53 s. Desaturation- and resaturation response time of SpO(2) was approximately 15 and 12 s shorter in SUB compared to TPULS, respectively. Lowest SpO(2) values were 76 +/- 10% for TPULS and 74 +/- 13% for SUB. HR traces for both pulse oximeters showed similar patterns. For static apneas, dropout rate was larger for SUB (18%) than for TPULS (<1%). SUB produced similar SpO(2) and HR values as TPULS, both during normoxic and hypoxic breathing (n = 20), and submersed static apneas (n = 6). SUB responds more quickly to changes in oxygen saturation when sensors were placed at the forehead. Further development of SUB is needed to limit signal loss, and its function should be tested at greater depth and lower saturation.

Place, publisher, year, edition, pages
2021. Vol. 12, article id 649674
National Category
Anesthesiology and Intensive Care Sport and Fitness Sciences
Identifiers
URN: urn:nbn:se:miun:diva-42084DOI: 10.3389/fphys.2021.649674ISI: 000648605200001PubMedID: 33981249Scopus ID: 2-s2.0-85105569725OAI: oai:DiVA.org:miun-42084DiVA, id: diva2:1556299
Available from: 2021-05-21 Created: 2021-05-21 Last updated: 2025-09-25

Open Access in DiVA

fulltext(4759 kB)1068 downloads
File information
File name FULLTEXT01.pdfFile size 4759 kBChecksum SHA-512
eeeb285b0aeadce00fcb972a4bc49a46f727643a47daf49fcbbc6fcd659c26cdaf056fa70b714040a36f2b650d325bfa2768bc6c81b08debf56322fb3e9b0c60
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Authority records

Mulder, EricSchagatay, Erika

Search in DiVA

By author/editor
Mulder, EricSchagatay, Erika
By organisation
Department of Health Sciences
In the same journal
Frontiers in Physiology
Anesthesiology and Intensive CareSport and Fitness Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 1074 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 264 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf