Mid Sweden University

miun.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Full-field X-ray fluorescence imaging with a straight polycapillary X-ray collimator
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.ORCID iD: 0000-0002-5619-409X
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.
2020 (English)In: Journal of Instrumentation, E-ISSN 1748-0221, Vol. 15, no 12, article id P12033Article in journal (Refereed) Published
Abstract [en]

Due to the availability of X-ray imaging detectors, full-field X-ray fluorescence (FF-XRF) imaging technique has become achievable, which provides an alternative to scanning X-ray fluorescence imaging with a micro-focus X-ray beamline. In this paper, we present a setup based on straight capillary optics and an energy-dispersive hybrid pixel detector, which can perform simultaneous mapping of several chemical elements. The photon transmission efficiency and spatial resolution are compared between two X-ray collimation setups: one using pinhole optics and one using straight polycapillary optics. There is a tradeoff between the spatial resolution and transmission efficiency when considering X-ray optics. When optimizing the spatial resolution, using straight capillary optics achieved a higher intensity gain when comparing with the pinhole setup. Characterization of the polycapillary imaging setup is performed through analyzing various samples in order to investigate the spatial frequency response and the energy sensitivity. This developed setup is capable of FF-XRF imaging in characteristic energies below 20 keV, while for higher energies the spatial resolution is affected by photon transmission through the collimator. This work shows the potential of the FF-XRF instrument in the monitoring of toxic metal distributions in environmental mapping measurements.

Place, publisher, year, edition, pages
2020. Vol. 15, no 12, article id P12033
Keywords [en]
Inspection with x-rays, X-ray fluorescence (XRF) systems, Hybrid detectors, X-ray transport and focusing
National Category
Atom and Molecular Physics and Optics Environmental Sciences
Identifiers
URN: urn:nbn:se:miun:diva-39936DOI: 10.1088/1748-0221/15/12/P12033ISI: 000608265500026Scopus ID: 2-s2.0-85099099203OAI: oai:DiVA.org:miun-39936DiVA, id: diva2:1469452
Available from: 2020-12-29 Created: 2020-09-21 Last updated: 2025-09-25Bibliographically approved
In thesis
1. X-ray Fluorescence Spectrometry for Environmental Applications
Open this publication in new window or tab >>X-ray Fluorescence Spectrometry for Environmental Applications
2020 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

Heavy metal contamination in environmental applications is particularly important because of its potential impact on associated ecosystems and human health. At present, monitoring of heavy metals is usually done by taking and preparing samples for off-line laboratory measurements. X-ray fluorescence (XRF) analysis is a powerful and widely used tool for determining the elemental composition and concentration of chemical species in materials. This project is a feasibility study for the possibility of on-line XRF systems for continuousand direct analysis of industrial processes and environmental emissions.

The feasibility of such measurements depends on the accuracy with which the concentration can be measured within a given response time. Therefore, this project is focused on investigating possible background suppression of the XRF spectrum. First, an XRF setup has been built, and its capability has been compared to a commercial scanning electron microscope with energy dispersive spectroscopy (SEM-EDS). The qualitative analysis and semi-quantitative analysis of heavy metal contamination in fly ash was performed and compared. Due to minimal sample preparation, the developed XRF system is suitable for in-situ measurements. A series of experiments was performed to optimize the signal-to-noise ratio of the spectra achieved from chromium contaminated liquid samples. The most significant factor turned out to be the primary X-ray source filter. Numerical simulation models have been developed in the Monte Carlo N-particle radiation transport code (MCNP), to calculate the X-ray fluorescence intensities and the detection limit for chromium in liquid samples. The experimental results agree with the results predicted by the simulation model, hence the model is used for optimization of the XRF system. Further, XRF mapping of chemical element distributions on a microscopic level has been obtained by using both X-ray scanning microscopy and full-field projection microscopy. The resultingdata from these microscopy measurements can guide further comprehensive environmental and industrial monitoring missions by providing additional spatial distribution information.

In conclusion, the first research contribution presented in this thesis is the demonstration of the possibility to perform in-situ XRF measurements of chromium contamination in leachate with a limit of detection below the legal environmental limits. The second is the demonstration of XRF mapping on amicroscopy level, where a polycapillary X-ray optics setup achieves a similar intensity as a geometrically corresponding pinhole optics setup.

Place, publisher, year, edition, pages
Sundsvall: Mid Sweden University, 2020. p. 43
Series
Mid Sweden University licentiate thesis, ISSN 1652-8948 ; 171
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:miun:diva-39979 (URN)978-91-88947-61-1 (ISBN)
Presentation
2020-10-08, C306, Holmgatan 10, Sundsvall, 10:00 (English)
Opponent
Supervisors
Note

Vid tidpunkten för framläggningen av avhandlingen var följande delarbeten opublicerade: delarbete 2 (inskickat), delarbete 3 (accepterat), delarbete 4 (accepterat).

At the time of the defence the following papers were unpublished: paper 2 (submitted), paper 3 (accepted), paper 4 (accepted).

Available from: 2020-09-29 Created: 2020-09-29 Last updated: 2025-09-25Bibliographically approved
2. Spectroscopic and Microscopic X-ray Fluorescence Analysis for Environmental and Industrial Applications
Open this publication in new window or tab >>Spectroscopic and Microscopic X-ray Fluorescence Analysis for Environmental and Industrial Applications
2022 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Heavy metals are well-known environmental pollutants due to its potential impact on associated ecosystems and human health. Thus, it is important to monitor the levels of heavy metals in the environment. X-ray fluorescence (XRF) analysis is a powerful and effective screening tool in measuring the concentration of multi-elements simultaneously.

This thesis provides insight into development and implementation of XRF instruments for environmental monitoring and industrial process control. The XRF method was compared with a commercial scanning electron microscope with energy dispersive spectroscopy (SEM-EDS) for fly ash samples. Qualitative analysis and semi-quantitative analysis of Na, S, Cl, K and Cd in incineration fly ash were performed with these two similar techniques. One of the challenges of using XRF is the scattering background noise from the primary beam, which decreases the detection limit and the sensitivity of the measurement system. Hence, an X-ray beam filter was chosen to suppress the background noise for a specific element, Cr, in leachate. Numerical simulations and experiments were developed to find the proper filter material and thickness by calculating the X-ray fluorescence intensities and the signal-to-noise ratio. The developed system is capable of online monitoring of Cr levels, to certify that the concentration is below the threshold level in leachate. An XRF prototype was built and calibrated for underwater Hg analysis in maritime wet sediment using a radioisotope source. The presented results show that it is possible to detect Hg by K-shell emission thus enabling XRF analysis for sediment underwater.

For non-homogeneous samples, an image revealing the elemental distribution can be achieved by micro-XRF (µ-XRF). XRF mapping of element distributions on a microscopic level was obtained by using scanning XRF microscopy and full-field XRF projection microscopy (FF-XRF). The spatial resolution of the scanning XRF imaging setup using an X-ray tube is in the order of 100 µm, but need to be further improved to measure the homogeneity of S on individual fiber level in pulp and paper industry. For the scanning technique, it is a tradeoff between resolution and measurement time. Another technique is FF-XRF imaging, and a setup was implemented using an energy resolving pixel detector and X-ray optics. The capabilities and limitations of using X-ray optics in XRF imaging systems have been identified. These microscopy measurements can guide further comprehensive environmental and industrial monitoring missions, utilizing elemental distribution information.

Place, publisher, year, edition, pages
Mid Sweden University, 2022. p. 47
Series
Mid Sweden University doctoral thesis, ISSN 1652-893X ; 371
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:miun:diva-45007 (URN)978-91-89341-66-1 (ISBN)
Public defence
2022-06-17, C312, Holmgatan 10, Sundsvall, Västernorrland, 13:00 (English)
Opponent
Supervisors
Note

At the time of the defence the following papers were unpublished: paper 3 (accepted), paper 4 (in manuscript), paper 6 (in manuscript).

Available from: 2022-05-18 Created: 2022-05-18 Last updated: 2025-09-25Bibliographically approved

Open Access in DiVA

fulltext(2372 kB)561 downloads
File information
File name FULLTEXT02.pdfFile size 2372 kBChecksum SHA-512
91ad6ba14a4b73f517fd9957a54ad074f102251289d250dba00ecc32eea3cc342cc87e0f5789a24efac62dcbe4a88ed41d81c7dd3e5020cba07511f98a729642
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Authority records

An, SiwenKrapohl, DavidNorlin, BörjeThungström, Göran

Search in DiVA

By author/editor
An, SiwenKrapohl, DavidNorlin, BörjeThungström, Göran
By organisation
Department of Electronics Design
In the same journal
Journal of Instrumentation
Atom and Molecular Physics and OpticsEnvironmental Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 563 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 921 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf