Signal-to-Noise Ratio Optimization in X-ray Fluorescence Spectrometry for Chromium Contamination Analysis
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design. (Radiation Sensor Systems)ORCID iD: 0000-0002-4196-6296
Högskolan i Gävle.
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.ORCID iD: 0000-0002-8325-5177
Show others and affiliations
2021 (English)In: Talanta: The International Journal of Pure and Applied Analytical Chemistry, ISSN 0039-9140, E-ISSN 1873-3573, Vol. 230, article id 122236Article in journal (Refereed) Published
Abstract [en]

In most cases, direct X-ray fluorescence (XRF) analysis of solutions entails technical difficulties due to a high X-ray scattering background resulting in a spectrum with a poor signal-to-noise ratio (SNR). Key factors that determine the sensitivity of the method are the energy resolution of the detector and the amount of scattered radiation in the energy range of interest. Limiting the width of the primary spectrum by the use of secondary targets, or filters, can greatly improve the sensitivity for specific portions of the spectrum. This paper demonstrates a potential method for SNR optimization in direct XRF analysis of chromium (Cr) contamination. The suggested method requires minimal sample preparation and achieves higher sensitivity compared to existing direct XRF analysis. Two states of samples, fly ash and leachate from municipal solid waste incineration, were investigated. The effects of filter material, its absorption edge and filter thickness were analyzed using the combination of Monte Carlo N-Particle (MCNP) code and energy-dispersive XRF spectrometry. The applied filter removes primary photons with energies interfering with fluorescence photons from the element of interest, thus results in lower background scattering in the spectrum. The SNR of Cr peak increases with filter thickness and reaches a saturation value when further increased thickness only increases the measurement time. Measurements and simulations show that a Cu filter with a thickness between 100 μm and 140 μm is optimal for detecting Cr by taking into account both the SNR and the exposure time. With direct XRF analysis for solutions, the limit of quantitation (LOQ) of the achieved system was 0.32 mg/L for Cr, which is well below the allowed standard limitation for landfills in Sweden. This work shows that XRF can gain enough sensitivity for direct monitoring to certify that the Cr content in leachate is below environmental limits.

Place, publisher, year, edition, pages
2021. Vol. 230, article id 122236
Keywords [en]
Chromium, Environmental monitoring, Hazardous materials, Limit of quantitation (LOQ), Waste management, X-ray fluorescence analysis (XRF)
National Category
Analytical Chemistry Environmental Management
Identifiers
URN: urn:nbn:se:miun:diva-39934DOI: 10.1016/j.talanta.2021.122236ISI: 000657143300001PubMedID: 33934759Scopus ID: 2-s2.0-85103402317OAI: oai:DiVA.org:miun-39934DiVA, id: diva2:1469406
Available from: 2021-03-31 Created: 2020-09-21 Last updated: 2025-09-25Bibliographically approved
In thesis
1. X-ray Fluorescence Spectrometry for Environmental Applications
Open this publication in new window or tab >>X-ray Fluorescence Spectrometry for Environmental Applications
2020 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

Heavy metal contamination in environmental applications is particularly important because of its potential impact on associated ecosystems and human health. At present, monitoring of heavy metals is usually done by taking and preparing samples for off-line laboratory measurements. X-ray fluorescence (XRF) analysis is a powerful and widely used tool for determining the elemental composition and concentration of chemical species in materials. This project is a feasibility study for the possibility of on-line XRF systems for continuousand direct analysis of industrial processes and environmental emissions.

The feasibility of such measurements depends on the accuracy with which the concentration can be measured within a given response time. Therefore, this project is focused on investigating possible background suppression of the XRF spectrum. First, an XRF setup has been built, and its capability has been compared to a commercial scanning electron microscope with energy dispersive spectroscopy (SEM-EDS). The qualitative analysis and semi-quantitative analysis of heavy metal contamination in fly ash was performed and compared. Due to minimal sample preparation, the developed XRF system is suitable for in-situ measurements. A series of experiments was performed to optimize the signal-to-noise ratio of the spectra achieved from chromium contaminated liquid samples. The most significant factor turned out to be the primary X-ray source filter. Numerical simulation models have been developed in the Monte Carlo N-particle radiation transport code (MCNP), to calculate the X-ray fluorescence intensities and the detection limit for chromium in liquid samples. The experimental results agree with the results predicted by the simulation model, hence the model is used for optimization of the XRF system. Further, XRF mapping of chemical element distributions on a microscopic level has been obtained by using both X-ray scanning microscopy and full-field projection microscopy. The resultingdata from these microscopy measurements can guide further comprehensive environmental and industrial monitoring missions by providing additional spatial distribution information.

In conclusion, the first research contribution presented in this thesis is the demonstration of the possibility to perform in-situ XRF measurements of chromium contamination in leachate with a limit of detection below the legal environmental limits. The second is the demonstration of XRF mapping on amicroscopy level, where a polycapillary X-ray optics setup achieves a similar intensity as a geometrically corresponding pinhole optics setup.

Place, publisher, year, edition, pages
Sundsvall: Mid Sweden University, 2020. p. 43
Series
Mid Sweden University licentiate thesis, ISSN 1652-8948 ; 171
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:miun:diva-39979 (URN)978-91-88947-61-1 (ISBN)
Presentation
2020-10-08, C306, Holmgatan 10, Sundsvall, 10:00 (English)
Opponent
Supervisors
Note

Vid tidpunkten för framläggningen av avhandlingen var följande delarbeten opublicerade: delarbete 2 (inskickat), delarbete 3 (accepterat), delarbete 4 (accepterat).

At the time of the defence the following papers were unpublished: paper 2 (submitted), paper 3 (accepted), paper 4 (accepted).

Available from: 2020-09-29 Created: 2020-09-29 Last updated: 2025-09-25Bibliographically approved
2. Spectroscopic and Microscopic X-ray Fluorescence Analysis for Environmental and Industrial Applications
Open this publication in new window or tab >>Spectroscopic and Microscopic X-ray Fluorescence Analysis for Environmental and Industrial Applications
2022 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Heavy metals are well-known environmental pollutants due to its potential impact on associated ecosystems and human health. Thus, it is important to monitor the levels of heavy metals in the environment. X-ray fluorescence (XRF) analysis is a powerful and effective screening tool in measuring the concentration of multi-elements simultaneously.

This thesis provides insight into development and implementation of XRF instruments for environmental monitoring and industrial process control. The XRF method was compared with a commercial scanning electron microscope with energy dispersive spectroscopy (SEM-EDS) for fly ash samples. Qualitative analysis and semi-quantitative analysis of Na, S, Cl, K and Cd in incineration fly ash were performed with these two similar techniques. One of the challenges of using XRF is the scattering background noise from the primary beam, which decreases the detection limit and the sensitivity of the measurement system. Hence, an X-ray beam filter was chosen to suppress the background noise for a specific element, Cr, in leachate. Numerical simulations and experiments were developed to find the proper filter material and thickness by calculating the X-ray fluorescence intensities and the signal-to-noise ratio. The developed system is capable of online monitoring of Cr levels, to certify that the concentration is below the threshold level in leachate. An XRF prototype was built and calibrated for underwater Hg analysis in maritime wet sediment using a radioisotope source. The presented results show that it is possible to detect Hg by K-shell emission thus enabling XRF analysis for sediment underwater.

For non-homogeneous samples, an image revealing the elemental distribution can be achieved by micro-XRF (µ-XRF). XRF mapping of element distributions on a microscopic level was obtained by using scanning XRF microscopy and full-field XRF projection microscopy (FF-XRF). The spatial resolution of the scanning XRF imaging setup using an X-ray tube is in the order of 100 µm, but need to be further improved to measure the homogeneity of S on individual fiber level in pulp and paper industry. For the scanning technique, it is a tradeoff between resolution and measurement time. Another technique is FF-XRF imaging, and a setup was implemented using an energy resolving pixel detector and X-ray optics. The capabilities and limitations of using X-ray optics in XRF imaging systems have been identified. These microscopy measurements can guide further comprehensive environmental and industrial monitoring missions, utilizing elemental distribution information.

Place, publisher, year, edition, pages
Mid Sweden University, 2022. p. 47
Series
Mid Sweden University doctoral thesis, ISSN 1652-893X ; 371
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:miun:diva-45007 (URN)978-91-89341-66-1 (ISBN)
Public defence
2022-06-17, C312, Holmgatan 10, Sundsvall, Västernorrland, 13:00 (English)
Opponent
Supervisors
Note

At the time of the defence the following papers were unpublished: paper 3 (accepted), paper 4 (in manuscript), paper 6 (in manuscript).

Available from: 2022-05-18 Created: 2022-05-18 Last updated: 2025-09-25Bibliographically approved

Open Access in DiVA

fulltext(3612 kB)1239 downloads
File information
File name FULLTEXT01.pdfFile size 3612 kBChecksum SHA-512
978ac033c4a252ec3c78662738249b77f6ae57b150c52737c09a608aabee3193d31f4f8862a435d0025bd892a522a9766c1f0aec47ee457cac479522ce924e27
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Authority records

An, SiwenNorlin, BörjeFröjdh, ChristerThungström, Göran

Search in DiVA

By author/editor
An, SiwenNorlin, BörjeFröjdh, ChristerThungström, Göran
By organisation
Department of Electronics Design
In the same journal
Talanta: The International Journal of Pure and Applied Analytical Chemistry
Analytical ChemistryEnvironmental Management

Search outside of DiVA

GoogleGoogle Scholar
Total: 1241 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 976 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf