Nytt Värmesystem till en skola: Beräkning av transmissions- och ventilationsförluster
Mid Sweden University, Faculty of Science, Technology and Media, Department of Chemical Engineering.
2020 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Med hjälp av Boverkets byggregler och de ISO-standarder som föreskrivs fastställs värmeeffektbehovet för Kyrkbackskolan, Ljusnarsbergs kommunala skola. Ur effektbehovet har sedan ett teoretiskt värmesystem dimensionerats. Resultaten visar att de olika byggnaderna som skolan består av har olika behov beroende på deras utformning. Över trehundra radiatorer och över trehundrafyrtio kilowatt värmeeffekt behövs för att värma skolan enligt de utförda beräkningarna för transmissionsförluster, ventilationsförluster och köldbryggor. Den största osäkerheten finns i köldbryggorna då dessa är baserade på tabellvärden. En rumslista visar vad varje rum i hela skolan har för effektbehov och kan användas vid både installation och injustering.

Abstract [en]

Using ”Boverkets byggregler” and the ISO-standards that are stipulated in it are the heating requirements determined for “Kyrkbackskolan”, the only school in the municipality of Ljusnarsberg. A theoretical heating system has been designed based on the calculations. The results show that the three different buildings that make up the school have different requirements depending on their layout. Over three hundred radiators and over three hundred forty kilowatts of heating power are required to heat the school according to the calculations of transmission losses, ventilation losses and thermal bridges. The largest insecurity is in the thermal bridges since they are determined using tables. A list shows all the rooms and their heating requirements which can be used when installing or tuning the heating system.

Place, publisher, year, edition, pages
2020. , p. 49
Keywords [en]
Transmission losses, ventilation losses, thermal bridges, heating system
Keywords [sv]
Transmissionsförluster, ventilationsförluster, köldbryggor, värmesystem
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:miun:diva-39316Local ID: ER-V20-G3-027OAI: oai:DiVA.org:miun-39316DiVA, id: diva2:1446140
Subject / course
Energy Technology EN2
Educational program
Energy Engineering TENIG 180 higher education credits
Supervisors
Examiners
Available from: 2020-06-24 Created: 2020-06-24 Last updated: 2025-09-25Bibliographically approved

Open Access in DiVA

fulltext(1844 kB)496 downloads
File information
File name FULLTEXT01.pdfFile size 1844 kBChecksum SHA-512
e5914e8ebf31fcaca0efc1377a8cbb8a74da1c031d07d9fb2047f8cc10630453e96995e89531391c2d979164bde73ea150b34a52a846855b5ea60267f9fc4c9f
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Öberg, Andreas
By organisation
Department of Chemical Engineering
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 496 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 410 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf