Comparison of Elemental Analysis Techniques for Fly Ash from Municipal Solid Waste Incineration using X-rays and Electron Beams
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.
Mid Sweden University, Faculty of Science, Technology and Media, Department of Natural Sciences.ORCID iD: 0000-0001-9137-3440
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.
2019 (English)In: IOP Conference Series: Earth and Environmental Science, Institute of Physics (IOP), 2019, Vol. 337, no 1, article id 012007Conference paper, Published paper (Refereed)
Abstract [en]

With the rapid expansion of the waste incineration business both in Europe and globally, there is a growing need for the elemental analysis for fly ash from municipal solid waste incineration. In this work, samples of washed and unwashed ash from municipal solid waste incineration in Sundsvall are evaluated. Qualitative analysis and semi-quantitative analysis are used to compare two elemental analysis methods, scanning electron microscope with energy dispersive spectroscopy (SEM-EDS) and X-ray fluorescence (XRF) measurement. Both methods are used to retrieve the difference in elemental composition between washed and unwashed fly ash. SEM-EDS accurately detects light elements from well-prepared samples in a vacuum environment, while, for online measurements, XRF is a potential method that analyses hazardous metal content in the fly ash. 

Place, publisher, year, edition, pages
Institute of Physics (IOP), 2019. Vol. 337, no 1, article id 012007
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:miun:diva-38235DOI: 10.1088/1755-1315/337/1/012007ISI: 000587908200007Scopus ID: 2-s2.0-85076187399OAI: oai:DiVA.org:miun-38235DiVA, id: diva2:1385687
Conference
International Scientific Conference on Efficient Waste Treatment 2018, EWT 2018, St. Petersburg, Russian Federation, 13 December 2018 through 14 December 2018
Available from: 2020-01-15 Created: 2020-01-15 Last updated: 2025-09-25Bibliographically approved
In thesis
1. X-ray Fluorescence Spectrometry for Environmental Applications
Open this publication in new window or tab >>X-ray Fluorescence Spectrometry for Environmental Applications
2020 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

Heavy metal contamination in environmental applications is particularly important because of its potential impact on associated ecosystems and human health. At present, monitoring of heavy metals is usually done by taking and preparing samples for off-line laboratory measurements. X-ray fluorescence (XRF) analysis is a powerful and widely used tool for determining the elemental composition and concentration of chemical species in materials. This project is a feasibility study for the possibility of on-line XRF systems for continuousand direct analysis of industrial processes and environmental emissions.

The feasibility of such measurements depends on the accuracy with which the concentration can be measured within a given response time. Therefore, this project is focused on investigating possible background suppression of the XRF spectrum. First, an XRF setup has been built, and its capability has been compared to a commercial scanning electron microscope with energy dispersive spectroscopy (SEM-EDS). The qualitative analysis and semi-quantitative analysis of heavy metal contamination in fly ash was performed and compared. Due to minimal sample preparation, the developed XRF system is suitable for in-situ measurements. A series of experiments was performed to optimize the signal-to-noise ratio of the spectra achieved from chromium contaminated liquid samples. The most significant factor turned out to be the primary X-ray source filter. Numerical simulation models have been developed in the Monte Carlo N-particle radiation transport code (MCNP), to calculate the X-ray fluorescence intensities and the detection limit for chromium in liquid samples. The experimental results agree with the results predicted by the simulation model, hence the model is used for optimization of the XRF system. Further, XRF mapping of chemical element distributions on a microscopic level has been obtained by using both X-ray scanning microscopy and full-field projection microscopy. The resultingdata from these microscopy measurements can guide further comprehensive environmental and industrial monitoring missions by providing additional spatial distribution information.

In conclusion, the first research contribution presented in this thesis is the demonstration of the possibility to perform in-situ XRF measurements of chromium contamination in leachate with a limit of detection below the legal environmental limits. The second is the demonstration of XRF mapping on amicroscopy level, where a polycapillary X-ray optics setup achieves a similar intensity as a geometrically corresponding pinhole optics setup.

Place, publisher, year, edition, pages
Sundsvall: Mid Sweden University, 2020. p. 43
Series
Mid Sweden University licentiate thesis, ISSN 1652-8948 ; 171
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:miun:diva-39979 (URN)978-91-88947-61-1 (ISBN)
Presentation
2020-10-08, C306, Holmgatan 10, Sundsvall, 10:00 (English)
Opponent
Supervisors
Note

Vid tidpunkten för framläggningen av avhandlingen var följande delarbeten opublicerade: delarbete 2 (inskickat), delarbete 3 (accepterat), delarbete 4 (accepterat).

At the time of the defence the following papers were unpublished: paper 2 (submitted), paper 3 (accepted), paper 4 (accepted).

Available from: 2020-09-29 Created: 2020-09-29 Last updated: 2025-09-25Bibliographically approved
2. Spectroscopic and Microscopic X-ray Fluorescence Analysis for Environmental and Industrial Applications
Open this publication in new window or tab >>Spectroscopic and Microscopic X-ray Fluorescence Analysis for Environmental and Industrial Applications
2022 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Heavy metals are well-known environmental pollutants due to its potential impact on associated ecosystems and human health. Thus, it is important to monitor the levels of heavy metals in the environment. X-ray fluorescence (XRF) analysis is a powerful and effective screening tool in measuring the concentration of multi-elements simultaneously.

This thesis provides insight into development and implementation of XRF instruments for environmental monitoring and industrial process control. The XRF method was compared with a commercial scanning electron microscope with energy dispersive spectroscopy (SEM-EDS) for fly ash samples. Qualitative analysis and semi-quantitative analysis of Na, S, Cl, K and Cd in incineration fly ash were performed with these two similar techniques. One of the challenges of using XRF is the scattering background noise from the primary beam, which decreases the detection limit and the sensitivity of the measurement system. Hence, an X-ray beam filter was chosen to suppress the background noise for a specific element, Cr, in leachate. Numerical simulations and experiments were developed to find the proper filter material and thickness by calculating the X-ray fluorescence intensities and the signal-to-noise ratio. The developed system is capable of online monitoring of Cr levels, to certify that the concentration is below the threshold level in leachate. An XRF prototype was built and calibrated for underwater Hg analysis in maritime wet sediment using a radioisotope source. The presented results show that it is possible to detect Hg by K-shell emission thus enabling XRF analysis for sediment underwater.

For non-homogeneous samples, an image revealing the elemental distribution can be achieved by micro-XRF (µ-XRF). XRF mapping of element distributions on a microscopic level was obtained by using scanning XRF microscopy and full-field XRF projection microscopy (FF-XRF). The spatial resolution of the scanning XRF imaging setup using an X-ray tube is in the order of 100 µm, but need to be further improved to measure the homogeneity of S on individual fiber level in pulp and paper industry. For the scanning technique, it is a tradeoff between resolution and measurement time. Another technique is FF-XRF imaging, and a setup was implemented using an energy resolving pixel detector and X-ray optics. The capabilities and limitations of using X-ray optics in XRF imaging systems have been identified. These microscopy measurements can guide further comprehensive environmental and industrial monitoring missions, utilizing elemental distribution information.

Place, publisher, year, edition, pages
Mid Sweden University, 2022. p. 47
Series
Mid Sweden University doctoral thesis, ISSN 1652-893X ; 371
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:miun:diva-45007 (URN)978-91-89341-66-1 (ISBN)
Public defence
2022-06-17, C312, Holmgatan 10, Sundsvall, Västernorrland, 13:00 (English)
Opponent
Supervisors
Note

At the time of the defence the following papers were unpublished: paper 3 (accepted), paper 4 (in manuscript), paper 6 (in manuscript).

Available from: 2022-05-18 Created: 2022-05-18 Last updated: 2025-09-25Bibliographically approved

Open Access in DiVA

fulltext(841 kB)1189 downloads
File information
File name FULLTEXT01.pdfFile size 841 kBChecksum SHA-512
8565db03e5f8e15d63172c2b4da3382d4787a0a27078d706b42e869b5c37bf2e6509b7771fa97c29f3e3995a1e14d6dbbc007871448aa1bc79fef930a3be88da
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Authority records

An, SiwenNorlin, BörjeHummelgård, MagnusThungström, Göran

Search in DiVA

By author/editor
An, SiwenNorlin, BörjeHummelgård, MagnusThungström, Göran
By organisation
Department of Electronics DesignDepartment of Natural Sciences
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 1193 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 900 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf