Mid Sweden University

miun.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Photon Counting X-ray Detector Systems
Mid Sweden University, Faculty of Science, Technology and Media, Department of Information Technology and Media. (STC)
2005 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

This licentiate thesis concerns the development and characterisation of X-ray imaging detector systems. “Colour” X-ray imaging opens up new perspectives within the fields of medical X-ray diagnosis and also in industrial X-ray quality control. The difference in absorption for different “colours” can be used to discern materials in the object. For instance, this information might be used to identify diseases such as brittle-bone disease. The “colour” of the X-rays can be identified if the detector system can process each X-ray photon individually. Such a detector system is called a “single photon processing” system or, less precise, a “photon counting system”.

With modern technology it is possible to construct photon counting detector systems that can resolve details to a level of approximately 50 µm. However with such small pixels a problem will occur. In a semiconductor detector each absorbed X-ray photon creates a cloud of charge which contributes to the picture achieved. For high photon energies the size of the charge cloud is comparable to 50 µm and might be distributed between several pixels in the picture. Charge sharing is a key problem since, not only is the resolution degenerated, but it also destroys the “colour” information in the picture.

The problem involving charge sharing which limits “colour” X-ray imaging is discussed in this thesis. Image quality, detector effectiveness and “colour correctness” are studied on pixellated detectors from the MEDIPIX collaboration. Characterisation measurements and simulations are compared to be able to understand the physical processes that take place in the detector. Simulations can show pointers for the future development of photon counting X-ray systems. Charge sharing can be suppressed by introducing 3D-detector structures or by developing readout systems which can correct the crosstalk between pixels.

Place, publisher, year, edition, pages
Sundsvall: Mid Sweden University , 2005.
Series
Mid Sweden University licentiate thesis, ISSN 1652-8948 ; 2
Keywords [en]
Monte Carlo simulation, Three-dimensional, Energy weighting, X-ray, Pixel detector, Charge sharing, Imaging, Medipix, Spectroscopy, Dental diagnosis, Image quality
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:miun:diva-41ISBN: 91-85317-01-2 (print)OAI: oai:DiVA.org:miun-41DiVA, id: diva2:2000
Presentation
2005-02-11, M102, Humlegården, Holmgatan 10, Sundsvall, 10:15 (English)
Opponent
Supervisors
Available from: 2007-11-29 Created: 2007-11-29 Last updated: 2025-09-25Bibliographically approved
List of papers
1. Monte Carlo simulation of the response of a pixellated 3D photodetector in silicon
Open this publication in new window or tab >>Monte Carlo simulation of the response of a pixellated 3D photodetector in silicon
2002 (English)In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN 0168-9002, E-ISSN 1872-9576, Vol. 487, no 1-2, p. 136-141Article in journal (Refereed) Published
Abstract [en]

The charge transport and X-ray photon absorption in three-dimensional (3D) X-ray pixel detectors have been studied using numerical simulations. The charge transport has been modelled using the drift-diffusion simulator MEDICI, while photon absorption has been studied using MCNP. The response of the entire pixel detector system in terms of charge sharing, line spread function and modulation transfer function, has been simulated using a system level Monte Carlo simulation approach. A major part of the study is devoted to the effect of charge sharing on the energy resolution in 3D-pixel detectors. The 3D configuration was found to suppress charge sharing much better than conventional planar detectors.

Keywords
Charge sharing, Detector, Monte Carlo simulation, Silicon, Three-dimensional, X-ray
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:miun:diva-377 (URN)10.1016/S0168-9002(02)00957-9 (DOI)000177177500022 ()2-s2.0-0037063080 (Scopus ID)877 (Local ID)877 (Archive number)877 (OAI)
Conference
3rd International Workshop on Radiation Imaging Detectors; Orosai, Sardinia; Italy; 23 September 2001 through 27 September 2001
Note

3rd International Workshop on Radiation Imaging Detectors, Sep 23-27, 2001, orosei, Italy

Available from: 2008-12-11 Created: 2008-12-11 Last updated: 2025-09-25Bibliographically approved
2. Spectroscopy applications for the Medipix photon counting X-ray system
Open this publication in new window or tab >>Spectroscopy applications for the Medipix photon counting X-ray system
2004 (English)In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN 0168-9002, E-ISSN 1872-9576, Vol. 531, no 1-2, p. 251-257Article in journal (Refereed) Published
Abstract [en]

Since the Medipix system is a photon counting system, it is possible to use it as a spectroscopic device, which is sensitive to the energy of the incoming photons. The system can, for example, be used to achieve the spectrum of an unknown source. Since it is an imaging system, it can be useful for energy dependent scattering experiments. The factors limiting the spectroscopic resolution are source and channel noise and detector non-uniformity. A well-known method for correction non-uniformity is to use mono energetic source and a threshold adjustment. However, since the threshold calibration is energy dependent, its use for sources with wider energy range is limited. We have shown an easy method to create threshold calibration masks for different thresholds that include both detector and channel stationary influences with analysis of histograms of series of images. The model for histograms was created assuming a standard dental X-ray source, which allows finding mask-creating parameters like threshold range (Vth and Vthadj). This procedure can be performed for each energy of interest. Based on these arrays, mask files that narrowed the threshold distribution close to the theoretical limit, were prepared. The limit of the spectroscopic resolution for the system was measured by analysing histograms for series of flat images under identical conditions.

Place, publisher, year, edition, pages
ELSEVIER SCIENCE BV, 2004
Keywords
X-ray, Imaging; Pixel detector; Medipix, Spectroscopy
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:miun:diva-363 (URN)10.1016/j.nima.2004.06.013 (DOI)000224233400036 ()1676 (Local ID)1676 (Archive number)1676 (OAI)
Conference
5th International Workshop on Radiation Imaging Detectors, Sep 07-11, 2003, Riga, latvia
Note
5th International Workshop on Radiation Imaging Detectors, Sep 07-11, 2003, Riga, LatviaAvailable from: 2008-12-11 Created: 2008-12-11 Last updated: 2025-09-25Bibliographically approved
3. Material recognition with the Medipix photon counting colour X-ray system.
Open this publication in new window or tab >>Material recognition with the Medipix photon counting colour X-ray system.
2004 (English)In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN 0168-9002, E-ISSN 1872-9576, Vol. 531, no 1-2, p. 265-269Article in journal (Refereed) Published
Abstract [en]

An energy sensitive imaging system like Medipixl has proved to be promising in distinguishing different materials in an X-ray image of an object. We propose a general method utilising X-ray energy information for materialrecognition. For objects where the thickness of the materials is unknown, a convenient material parameter to identify is K = α1/α2, which is the ratio of the logarithms of the measured transmissions In(t1)/In(t2). If a database of the parameter K for different materials and energies is created, this method can be used for material recognition independent of the thickness of the materials. Series of images of an object consisting of aluminium and silicon were taken with different energy thresholds. The X-ray absorption for silicon and aluminium is very similar for the range 40-60 keV and only differs for lower energies. The results show that it is possible to distinguish between aluminium and silicon on images achieved by Medipixl using a standard dental source. By decreasing the spatial resolution a better contrast between the materials was achieved. The resolution of contrasts shown by the histograms was close to the limit of the system due to the statistical noise of the signal.

National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:miun:diva-364 (URN)10.1016/j.nima.2004.06.015 (DOI)000224233400038 ()1686 (Local ID)1686 (Archive number)1686 (OAI)
Conference
5th International Workshop on Radiation Imaging Detectors, Sep 07-11, 2003, Riga, Latvia
Note
5th International Workshop on Radiation Imaging Detectors, Sep 07-11, 2003, Riga, LatviaAvailable from: 2008-12-11 Created: 2008-12-11 Last updated: 2025-09-25Bibliographically approved
4. Energy dependence in dental imaging with Medipix2
Open this publication in new window or tab >>Energy dependence in dental imaging with Medipix2
2005 (English)In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN 0168-9002, E-ISSN 1872-9576, Vol. 546, no 1-2, p. 19-23Article in journal (Refereed) Published
Abstract [en]

The possibility to achieve better contrast in dental images by selecting specific X-ray energies is investigated. By applying both the low and the high photon counting energy threshold of the Medipix2 chip only a narrow interval of the spectrum of a 60 keV standard dental source used is selected. The relative contrast between the parts of the tooth with the highest respectively lowest absorption increases 18 % when the energy spread of the X-rays is narrowed from the full spectrum to a 4 keV window centered around 36 keV. The small tail of high energy photons from the full source spectrum lowers the achieved relative contrast significantly. This result can be used in development of X-ray sources or in consideration of energy weighting.

Keywords
Dental diagnosis; X-ray; Image quality; Pixel detector; Medipix, Energy weighting
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:miun:diva-365 (URN)10.1016/j.nima.2005.03.035 (DOI)000230288200004 ()2261 (Local ID)2261 (Archive number)2261 (OAI)
Conference
6th International Workshop on Radiation Imaging Detectors, Jul 25-29, 2004, Glasgow, Scotland
Note
6th International Workshop on Radiation Imaging Detectors, Jul 25-29, 2004, Glasgow, ScotlandAvailable from: 2008-12-11 Created: 2008-12-11 Last updated: 2025-09-25Bibliographically approved

Open Access in DiVA

fulltext(781 kB)2934 downloads
File information
File name FULLTEXT01.pdfFile size 781 kBChecksum SHA-1
5799df9f5909ee02ad696ab51756a7b599780cd4fef2c8aa14a8dfe4a295428ecc252bb4
Type fulltextMimetype application/pdf

Authority records

Norlin, Börje

Search in DiVA

By author/editor
Norlin, Börje
By organisation
Department of Information Technology and Media
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 2941 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 2114 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf