Mittuniversitetet

miun.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A novel compression garment with adhesive silicone stripes improves repeated sprint performance: a multi-experimental approach on the underlying mechanisms.
Mittuniversitetet, Fakulteten för humanvetenskap, Avdelningen för hälsovetenskap. (Swedish Winter Sports Research Centre)ORCID-id: 0000-0002-3814-6246
2014 (Engelska)Ingår i: BMC Sports Science, Medicine and Rehabilitation, E-ISSN 2052-1847 , Vol. 6, nr 21Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

BACKGROUND:

Repeated sprint performance is determined by explosive production of power, as well as rapid recovery between successive sprints, and there is evidence that compression garments and sports taping can improve both of these factors.

METHODS:

In each of two sub-studies, female athletes performed two sets of 30 30-m sprints (one sprint per minute), one set wearing compression garment with adhesive silicone stripes (CGSS) intended to mimic taping and the other with normal clothing, in randomized order. Sub-study 1 (n = 12) focused on cardio-respiratory, metabolic, hemodynamic and perceptual responses, while neuronal and biomechanical parameters were examined in sub-study 2 (n = 12).

RESULTS:

In both sub-studies the CGSS improved repeated sprint performance during the final 10 sprints (best P < 0.01, d = 0.61). None of the cardio-respiratory or metabolic variables monitored were altered by wearing this garment (best P = 0.06, d = 0.71). Also during the final 10 sprints, rating of perceived exertion by the upper leg muscles was reduced (P = 0.01, d = 1.1), step length increased (P = 0.01, d = 0.91) and activation of the m. rectus femoris elevated (P = 0.01, d = 1.24), while the hip flexion angle was lowered throughout the protocol (best P < 0.01, d = 2.28) and step frequency (best P = 0.34, d = 0.2) remained unaltered.

CONCLUSION:

Although the physiological parameters monitored were unchanged, the CGSS appears to improve performance during 30 30-m repeated sprints by reducing perceived exertion and altering running technique.

Ort, förlag, år, upplaga, sidor
2014. Vol. 6, nr 21
Nationell ämneskategori
Idrottsvetenskap och fitness Fysiologi och anatomi
Identifikatorer
URN: urn:nbn:se:miun:diva-23794DOI: 10.1186/2052-1847-6-21Scopus ID: 2-s2.0-84925855602OAI: oai:DiVA.org:miun-23794DiVA, id: diva2:772089
Tillgänglig från: 2014-12-16 Skapad: 2014-12-16 Senast uppdaterad: 2025-09-25Bibliografiskt granskad

Open Access i DiVA

fulltext(437 kB)980 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 437 kBChecksumma SHA-512
f39fa2ecae815515d8917a19849a0a53f61942a79951b4b0943ee6e13510b5323ba8e2a28fb0024a7340f8cec371615b5ff9630c90a49e0212e0f578a104c9ce
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextScopus

Person

Holmberg, Hans-Christer

Sök vidare i DiVA

Av författaren/redaktören
Holmberg, Hans-Christer
Av organisationen
Avdelningen för hälsovetenskap
I samma tidskrift
BMC Sports Science, Medicine and Rehabilitation
Idrottsvetenskap och fitnessFysiologi och anatomi

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 986 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 1698 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf