Factors influencing the determination of analyte ion surface partitioning coefficients in electrosprayed droplets
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för naturvetenskap.ORCID-id: 0000-0002-3646-294X
2001 (Engelska)Ingår i: Journal of the American Society for Mass Spectrometry, ISSN 1044-0305, Vol. 12, nr 9, s. 1002-1010Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The observed response in mass spectrometry utilizing electrospray as a sample introduction technique can be affected by a number of factors. In this study a series of two-electrolyte systems was investigated and the mass spectrometric responses were modeled by the use of droplet surface partitioning coefficients and instrumental response factors according to a recently reported method (Sjo¨berg et al., Anal. Chem. 2001, 73, 23–28). The partitioning coefficient and the instrumental response factor were found to be affected by the chosen experimental conditions. Experimental parameters that were investigated include spray position relative to the orifice, spray potential, nebulizer and curtain gas flow rates, ionic strength, and organic content of the sprayed solution. The time history of the generated droplets turned out to be of importance to both the partitioning coefficients and the instrumental response factor. For example, a general increase in the surface partitioning coefficients for the tetrapentylammonium ion was initially observed when the spray was aiming closer to the sampling orifice. Furthermore, it was shown with a small amount of deuterium labeled electrolyte that the total ionic strength and not just the electrolyte concentration influence the instrumental response factor. (J Am Soc Mass Spectrom 2001, 12, 1002–1010)

Ort, förlag, år, upplaga, sidor
2001. Vol. 12, nr 9, s. 1002-1010
Nyckelord [en]
electrospray ionization
Nationell ämneskategori
Kemi
Identifikatorer
URN: urn:nbn:se:miun:diva-2521DOI: 10.1016/S1044-0305(01)00281-1Lokalt ID: 1777OAI: oai:DiVA.org:miun-2521DiVA, id: diva2:27553
Tillgänglig från: 2008-09-30 Skapad: 2008-09-30 Senast uppdaterad: 2025-09-25Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Person

Bylund, Dan

Sök vidare i DiVA

Av författaren/redaktören
Bylund, Dan
Av organisationen
Institutionen för naturvetenskap
Kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 198 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf