Operational experience with Adaptive Gain Integrating Pixel Detectors at European XFEL
Visa övriga samt affilieringar
2024 (Engelska)Ingår i: Frontiers in Physics, E-ISSN 2296-424X, Vol. 11, artikel-id 1329378Artikel, forskningsöversikt (Refereegranskat) Published
Abstract [en]

The European X-ray Free Electron Laser (European XFEL) is a cutting-edge user facility that generates per second up to 27,000 ultra-short, spatially coherent X-ray pulses within an energy range of 0.26 to more than 20 keV. Specialized instrumentation, including various 2D X-ray detectors capable of handling the unique time structure of the beam, is required. The one-megapixel AGIPD (AGIPD1M) detectors, developed for the European XFEL by the AGIPD Consortium, are the primary detectors used for user experiments at the SPB/SFX and MID instruments. The first AGIPD1M detector was installed at SPB/SFX when the facility began operation in 2017, and the second one was installed at MID in November 2018. The AGIPD detector systems require a dedicated infrastructure, well-defined safety systems, and high-level control procedures to ensure stable and safe operation. As of now, the AGIPD1M detectors installed at the SPB/SFX and MID experimental end stations are fully integrated into the European XFEL environment, including mechanical integration, vacuum, power, control, data acquisition, and data processing systems. Specific high-level procedures allow facilitated detector control, and dedicated interlock systems based on Programmable Logic Controllers ensure detector safety in case of power, vacuum, or cooling failure. The first 6 years of operation have clearly demonstrated that the AGIPD1M detectors provide high-quality scientific results. The collected data, along with additional dedicated studies, have also enabled the identification and quantification of issues related to detector performance, ensuring stable operation. Characterization and calibration of detectors are among the most critical and challenging aspects of operation due to their complex nature. A methodology has been developed to enable detector characterization and data correction, both in near real-time (online) and offline mode. The calibration process optimizes detector performance and ensures the highest quality of experimental results. Overall, the experience gained from integrating and operating the AGIPD detectors at the European XFEL, along with the developed methodology for detector characterization and calibration, provides valuable insights for the development of next-generation detectors for Free Electron Laser X-ray sources. 

Ort, förlag, år, upplaga, sidor
Frontiers Media SA , 2024. Vol. 11, artikel-id 1329378
Nyckelord [en]
2D detectors, adaptive gain, calibration, FEL instrumentation, MHz X-ray detectors
Nationell ämneskategori
Subatomär fysik
Identifikatorer
URN: urn:nbn:se:miun:diva-50915DOI: 10.3389/fphy.2023.1329378ISI: 001179256700001Scopus ID: 2-s2.0-85187108570OAI: oai:DiVA.org:miun-50915DiVA, id: diva2:1845731
Tillgänglig från: 2024-03-20 Skapad: 2024-03-20 Senast uppdaterad: 2025-09-25

Open Access i DiVA

fulltext(7898 kB)341 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 7898 kBChecksumma SHA-512
167d775d074c6b84bf0651d3788818b27b88fe4096d0054b2393b98eba73f0fae66a1730902b315f7907e80c7bef08f6db3db4423de8538cb6b108b690e68d2f
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextScopus

Person

Graafsma, Heinz

Sök vidare i DiVA

Av författaren/redaktören
Graafsma, Heinz
Av organisationen
Institutionen för data- och elektroteknik (2023-)
I samma tidskrift
Frontiers in Physics
Subatomär fysik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 343 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 471 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf