Mittuniversitetet

miun.sePublikationer
Driftmeddelande
För närvarande är det driftstörningar. Felsökning pågår.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Evaluation of the use of class B LoraWAn for the coordination of distributed interface protection systems in smart grids
Visa övriga samt affilieringar
2020 (Engelska)Ingår i: Journal of Sensor and Actuator Networks, E-ISSN 2224-2708, Vol. 9, nr 1, artikel-id 13Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The adoption of the distributed generation paradigm is introducing several changes in the design and operation of modern distribution networks. Modern grid codes are becoming more and more complex, and the adoption of smart protection systems is becoming mandatory. However, the adoption of newer and smarter units is only half of the story. Proper communication networks must be provided as well, and the overall costs may become critical. In this work, the adoption of the Long-Range Wide Area Network (LoRaWAN) technology is suggested as a viable approach to implement the coordination of Interface Protection Systems. A proper communication architecture based on the LoRaWAN Class B technology was proposed and evaluated in order to assess its feasibility for the considered application. A scalability analysis was carried out, by computing the number of devices that can be handled by a single LoRaWAN Gateway (GW) and the maximum expected time of response between a triggering event and the arrival of the related coordination command. The results of the study showed that up to 312 devices can be managed by a single GW, by assuring a maximum response time of 22.95 s. A faster maximum response time of 6.2 s is also possible by reducing the number of managed devices to 12. © 2020 by the authors.

Ort, förlag, år, upplaga, sidor
MDPI AG , 2020. Vol. 9, nr 1, artikel-id 13
Nyckelord [en]
Distributed generation, Interface protection systems, LoRaWAN, LPWAN, Smart grid
Identifikatorer
URN: urn:nbn:se:miun:diva-41519DOI: 10.3390/jsan9010013ISI: 000525258000008Scopus ID: 2-s2.0-85080073940OAI: oai:DiVA.org:miun-41519DiVA, id: diva2:1536266
Tillgänglig från: 2021-03-10 Skapad: 2021-03-10 Senast uppdaterad: 2025-09-25Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Sisinni, Emiliano

Sök vidare i DiVA

Av författaren/redaktören
Sisinni, Emiliano
I samma tidskrift
Journal of Sensor and Actuator Networks

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 19 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf