A Bio-Compatible Fiber Optic pH Sensor Based on a Thin Core Interferometric Technique
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för elektronikkonstruktion.
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för elektronikkonstruktion.ORCID-id: 0000-0003-1967-4016
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för elektronikkonstruktion.ORCID-id: 0000-0003-2965-0288
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för elektronikkonstruktion. RISE Acreo.ORCID-id: 0000-0002-0631-3804
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: Photonics, ISSN 2304-6732, Vol. 6, nr 1, artikel-id 11Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

There is an increasing demand for compact, reliable and versatile sensor concepts for pH-level monitoring within several industrial, chemical as well as bio-medical applications. Many pHsensors concepts have been proposed, however, there is still a need for improved sensor solutionswith respect to reliability, durability and miniaturization but also for multiparameter sensing. Here wepresent a conceptual verification, which includes theoretical simulations as well as experimentalevaluation of a fiber optic pH-sensor based on a bio-compatible pH sensitive material not previouslyused in this context. The fiber optic sensor is based on a Mach-Zehnder interferometric technique,where the pH sensitive material is coated on a short, typically 20-25 mm thin core fiber splicedbetween two standard single mode fibers. The working principle of the sensor is simulated by usingCOMSOL Multiphysics. The simulations are used as a guideline for the construction of the sensorsthat have been experimentally evaluated in different liquids with pH ranging from 1.95 to 11.89. The results are promising, showing the potential for the development of bio-compatible fiber optic pH sensor with short response time, high sensitivity and broad measurement range. The developedsensor concept can find future use in many medical- or bio-chemical applications as well as inenvironmental monitoring of large areas. Challenges encountered during the sensor developmentdue to variation in the design parameters are discussed.

Ort, förlag, år, upplaga, sidor
2019. Vol. 6, nr 1, artikel-id 11
Nyckelord [en]
interferometric, Mach-Zehnder, pH, sensor, hydrogel, simulation
Nationell ämneskategori
Atom- och molekylfysik och optik
Identifikatorer
URN: urn:nbn:se:miun:diva-35646DOI: 10.3390/photonics6010011ISI: 000464341200003Scopus ID: 2-s2.0-85063143389OAI: oai:DiVA.org:miun-35646DiVA, id: diva2:1288828
Anmärkning

MDPI Photonics Special Issue "Advanced Optical Materials and Devices"

Tillgänglig från: 2019-02-14 Skapad: 2019-02-14 Senast uppdaterad: 2025-09-25Bibliografiskt granskad
Ingår i avhandling
1. Hydrogel-based pH-sensors: Development and characterisation of optical and electrical pH sensors based on stimuli-responsive hydrogels
Öppna denna publikation i ny flik eller fönster >>Hydrogel-based pH-sensors: Development and characterisation of optical and electrical pH sensors based on stimuli-responsive hydrogels
2019 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

The ability to measure the chemical parameter pH is of high importance in many areas. With new government regulations and evolving markets, there is a strong motivation for improving such measurements and conducting research on new types of pH sensors and sensor materials. Stimuli-responsive hydrogels (a group of polymers) have attracted a lot of attention in recent decades, due to their ability to be customized to suit many applications. One specific area where they have attracted attention is pH sensor technology.

Two stimuli-responsive hydrogels are used in this thesis. One is a non-toxic hydrogel, 1,4-acryl-terminated oligo(beta-amino esters) (1,4-AOBAE). Although it was previously used in drug- and DNA- delivery systems, it has not (to my knowledge) been used in a sensor configuration, and thus it is interesting to study. The second hydrogel, 1,3-acryl-terminated oligo(beta-amino esters) (1,3-AOBAE), is an improved variant of the first one. This improved hydrogel was synthesized because the original hydrogel crystallizes at room temperature, which meant that it was not optimal for various coating techniques. This hydrogel was characterized and verified for pH responsivity in two sensor configurations: electrical and optical. Designing a hydrogel for a specific application can be a complex procedure due to the many synthesizing parameters. For example, increasing a hydrogel's mechanical strength by introducing a higher degree of cross linking, leads to a smaller mesh size, which in turn leads to a lower diffusion rate and less solution absorption. The two hydrogels examined in this thesis respond to pH changes by absorbing or desorbing water; this change in the hydrogel's water content also changes its effective refractive index and permittivity. These changes can be measured using optical or electrical sensor systems. Three types of sensor systems were used in this thesis to verify the hydrogel's pH response and to ensure that they are suitable for use in thin-film techniques on various substrates (e.g. glass and plastic). The experimental results prove that these hydrogels are suitable for use in both electrical and optical sensor configurations. For electrical systems, a pH range of approximately 3-12 was achieved, and for optical, the range was approximately 2-12. These ranges can likely be improved, as the sensor film delaminated from the substrate at low pHs due to adhesion problems and as measurements above 12 were not conducted.

The findings of this thesis could, after more research, have strong implications for the development of improved pH-sensor configurations, especially for medical and healthcare applications and in environmental monitoring.

Abstract [sv]

Möjligheten att mäta den kemiska parametern pH är av stor betydelse inom många områden. Nya regler från myndigheter och tillväxtmarknader gör att det finns det en stark motivation för förbättring av och forskning om nya typer av pH-sensorer och sensormaterial. Stimuli-responsiva hydrogeler (en grupp polymerer) är ett material som under de senaste årtiondena uppmärksammats på grund av deras förmåga att skräddarsys för att passa många olika applikationer. Ett specifikt område där de har uppmärksammats är i pH-sensorteknik.

I arbetet presenterat i denna avhandling har två stimuli-responsiva hydrogeler använts. Dessa båda icke-toxiska hydrogeler har tidigare använts i olika läkemedel samt till DNA leverans system, men däremot inte till pH sensorer, vilket har gjorts i detta arbete. Hydrogelerna har använts för att konstruera och tillverka optiska pH sensorer baserade på fiberoptik samt elektriska sensorer med kapacitiv utläsning. Att syntetisera en hydrogel för en specifik applikation kan vara komplicerat, vilket beror på de många syntetiseringsparametrar som är inblandade vid tillverkning. Till exempel, leder införande av en högre tvärbindningsgrad till ökad mekaniska styrka hos hydrogelen, men också till en mindre maskstorlek, vilket i sin tur leder till en minskning av diffusions-hastigheten och absorption av lösningen. De två hydrogeler som undersöks i denna avhandling reagerar på pH-förändringar genom att absorbera eller desorbera vatten. Förändring av vattenhalt i hydrogelen ändrar också dess effektiva brytningsindex och permittivitet. Dessa ändringar av brytningsindex eller permittivitet kan med fördel mätas med optiska eller elektriska sensorsystem. Tre olika typer av sensorsystem har använts för att verifiera hydrogelens pH-respons och och dess lämplighet att användas i tunnfilms-teknik på olika substrat (glas och plast). Experimentella undersökningar har visat att de undersökta hydrogelerna är lämpliga att användas i både elektriska och optiska sensor konfigurationer. Det elektriska systemet visade sig känsligt för pH förändringar mellan ~3-12, och optiska system mellan ~2-12. Det observerades att låga pH värden ger en så stor volymsförändring av polymeren att denna då släpper ifrån underlaget. Det är därför troligt att  mätintervallet kan utökas om vidhäftningen mellan polymer och underlag kan förbättras.

Resultaten från denna avhandling kan med ytterligare forskning ha en stark inverkan på utvecklingen av förbättrade pH-sensor konfigurationer, särskilt inom medicinska- och hälsovårds-applikationer samt miljöövervakning.

Ort, förlag, år, upplaga, sidor
Sundsvall: Mid Sweden University, 2019. s. 61
Serie
Mid Sweden University doctoral thesis, ISSN 1652-893X ; 295
Nyckelord
Hydrogel, fiber optics, printed electronics, pH, sensor
Nationell ämneskategori
Elektroteknik och elektronik
Identifikatorer
urn:nbn:se:miun:diva-35647 (URN)978-91-88527-93-6 (ISBN)
Disputation
2019-03-19, O102, Holmgatan 10, Sundsvall, 13:15 (Engelska)
Opponent
Handledare
Tillgänglig från: 2019-02-19 Skapad: 2019-02-14 Senast uppdaterad: 2025-09-25Bibliografiskt granskad

Open Access i DiVA

fulltext(6516 kB)1601 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 6516 kBChecksumma SHA-512
96308032f872be3c9f4330794387a58aebd0b053297c0ab0a4f3fc371eb0114e828e50bb1b8f24dac63107cc9a1f05bc3518db3a2d3e1d353d1607f2f04abf64
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextScopus

Person

Engholm, MagnusHammarling, KristerAndersson, HenrikSandberg, MatsNilsson, Hans-Erik

Sök vidare i DiVA

Av författaren/redaktören
Engholm, MagnusHammarling, KristerAndersson, HenrikSandberg, MatsNilsson, Hans-Erik
Av organisationen
Institutionen för elektronikkonstruktion
I samma tidskrift
Photonics
Atom- och molekylfysik och optik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 1605 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 907 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf