Mittuniversitetet

miun.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Topical application of cream containing nonivamide and nicoboxil does not enhance the performance of experienced cyclists during a 4-km time-trial
Univ Wurzburg, Dept Sport Sci, Integrat & Expt Training Sci, Judenbhulweg 11, D-97082 Wurzburg, Germany.
Mittuniversitetet, Fakulteten för humanvetenskap, Avdelningen för hälsovetenskap.ORCID-id: 0000-0002-3814-6246
Univ Wurzburg, Dept Sport Sci, Integrat & Expt Training Sci, Judenbhulweg 11, D-97082 Wurzburg, Germany.
2016 (Engelska)Ingår i: European Journal of Applied Physiology, ISSN 1439-6319, E-ISSN 1439-6327, Vol. 116, nr 5, s. 969-974Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Topical application of nonivamide-nicoboxil cream to resting legs has been shown to enhance the level of oxygenated haemoglobin in leg muscles 15 min later. Here, we examined whether such application improves the performance of experienced cyclists in a subsequent 4-km time-trial. Nine male cyclists [26 +/- A 8 years; 176 +/- A 9 cm; 73.5 +/- A 12.8 kg; peak oxygen uptake: 50.7 +/- A 4.0 mL min(-1) kg(-1) (mean +/- A SD)] performed three 4-km time-trials on an ergometer with either topical application of nonivamide-nicoboxil cream (CREAM) or cream without active components (SHAM) to both their thigh muscles or no application (CONTROL). Only the skin temperature immediately before and after the time-trial was higher with cream than SHAM and CONTROL (best p < 0.001, best d = 1.16). All other parameters evaluated, i.e., the average power output during the time-trial (p > 0.05, best d = 0.08), the tissue saturation index of the m. vastus lateralis (p > 0.05, best d = 0.57), cardiac output, heart rate, oxygen uptake, blood lactate concentration, and perceived exertion (p > 0.05, best d = 1.1) were similar under all three conditions. Our present findings reveal that topical application of cream containing nonivamide and nicoboxil to the thighs of cyclists prior to a 4-km time-trial does not improve their power output, saturation of the m. vastus lateralis with oxygen, oxygen uptake, heart rate, cardiac parameters, or perceived level of exertion.

Ort, förlag, år, upplaga, sidor
2016. Vol. 116, nr 5, s. 969-974
Nyckelord [en]
Cycling, Finalgon, Near-infrared spectroscopy, Warm-up
Nationell ämneskategori
Hälsovetenskaper
Identifikatorer
URN: urn:nbn:se:miun:diva-29486DOI: 10.1007/s00421-016-3357-3ISI: 000374398200011PubMedID: 27002820Scopus ID: 2-s2.0-84961793696OAI: oai:DiVA.org:miun-29486DiVA, id: diva2:1054839
Tillgänglig från: 2016-12-09 Skapad: 2016-12-09 Senast uppdaterad: 2025-09-25Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Holmberg, Hans-Christer

Sök vidare i DiVA

Av författaren/redaktören
Holmberg, Hans-Christer
Av organisationen
Avdelningen för hälsovetenskap
I samma tidskrift
European Journal of Applied Physiology
Hälsovetenskaper

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 334 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf