Mid Sweden University

miun.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Stability of (B4C)-B-10 thin films under neutron radiation
European Spallat Source ESS AB, SE-22100 Lund, Sweden.
Tech Univ Munich, Heinz Maier Leibnitz Zentrum MLZ, FRM 2, D-85748 Garching, Germany.
Tech Univ Munich, Heinz Maier Leibnitz Zentrum MLZ, FRM 2, D-85748 Garching, Germany.
Linkoping Univ, Dept Phys Chem & Biol IFM, Thin Film Phys Div, SE-58183 Linkoping, Sweden.
Vise andre og tillknytning
2015 (engelsk)Inngår i: Radiation Physics and Chemistry, ISSN 0969-806X, E-ISSN 1879-0895, Vol. 113, s. 14-19Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Thin films of (B4C)-B-10 have shown to be very suitable as neutron-converting material in the next generation of neutron detectors, replacing the previous predominantly used He-3. In this contribution we show under realistic conditions that (B4C)-B-10 films are not damaged by the neutron irradiation and interactions, which they will be exposed to under many years in a neutron detector. 1 mu m thick (B4C)-B-10 thin films were deposited onto Al or Si substrates using dc magnetron sputtering. As-deposited films were exposed to a cold neutron beam with fluences of up to 1.1 x 10(14) cm(-2) and a mean wavelength of 6.9 angstrom. Both irradiated and as-deposited reference samples were characterized with time-of-flight elastic recoil detection analysis, scanning electron microscopy, transmission electron microscopy, X-ray photoemission spectroscopy, and X-ray diffraction. We show that only 1.8 ppm of the B-10 atoms were consumed and that the film composition does not change by the neutron interaction within the measurement accuracy. The irradiation does not deteriorate the film adhesion and there is no indication that it results in increased residual stress values of the as-deposited films of 0.095 GPa. From what is visible with the naked eye and down to atomic level studies, no change from the irradiation could be found using the above-mentioned characterization techniques. (C) 2015 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

sted, utgiver, år, opplag, sider
2015. Vol. 113, s. 14-19
Emneord [en]
Neutron, Radiation damage, Thin film, (B4C)-B-10, Neutron detection
HSV kategori
Identifikatorer
URN: urn:nbn:se:miun:diva-25658DOI: 10.1016/j.radphyschem.2015.04.006ISI: 000356196600003Scopus ID: 2-s2.0-84928320253Lokal ID: STCOAI: oai:DiVA.org:miun-25658DiVA, id: diva2:849377
Tilgjengelig fra: 2015-08-28 Laget: 2015-08-18 Sist oppdatert: 2025-09-25bibliografisk kontrollert

Open Access i DiVA

fulltext(1578 kB)1093 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1578 kBChecksum SHA-512
ecc994c91fe9658957128cc9b5aab03cecbd0860d1b878058c5879d1f18572d42b8040ccbb3e31a37d37f397b0fbee755a89c7c91ecab4ea7e58d7f5f58d5d57
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstScopus

Person

Hall-Wilton, Richard

Søk i DiVA

Av forfatter/redaktør
Hall-Wilton, Richard
Av organisasjonen
I samme tidsskrift
Radiation Physics and Chemistry

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 1093 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 614 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf