Mid Sweden University

miun.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Effect of slope and footwear on running economy and kinematics
Research Unit EA4660, Culture Sport Health Society and Exercise Performance Health Innovation Platform, Franche-Comté University, Besançon, France .
Mittuniversitetet, Fakulteten för humanvetenskap, Avdelningen för hälsovetenskap. (NVC)
Mittuniversitetet, Fakulteten för humanvetenskap, Avdelningen för hälsovetenskap. (NVC)
Research Unit EA4660, Culture Sport Health Society and Exercise Performance Health Innovation Platform, Franche-Comté University, Besançon, France .
2013 (engelsk)Inngår i: Scandinavian Journal of Medicine and Science in Sports, ISSN 0905-7188, E-ISSN 1600-0838, Vol. 23, nr 4, s. e246-e253Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Lower energy cost of running (Cr) has been reported when wearing minimal (MS) vs traditional shoes (TS) on level terrain, but the effect of slope on this difference is unknown. The aim of this study was to compare Cr, physiological, and kinematic variables from running in MS and TS on different slope conditions. Fourteen men (23.4 +/- 4.4 years; 177.5 +/- 5.2cm; 69.5 +/- 5.3kg) ran 14 5-min trials in a randomized sequence at 10km/h on a treadmill. Subjects ran once wearing MS and once wearing TS on seven slopes, from -8% to +8%. We found that Cr increased with slope gradient (P<0.01) and was on average 1.3% lower in MS than TS (P<0.01). However, slope did not influence the Cr difference between MS and TS. In MS, contact times were lower (P<0.01), flight times (P=0.01) and step frequencies (P=0.02) were greater at most slope gradients, and plantar-foot angles - and often ankle plantar-flexion (P=0.01) - were greater (P<0.01). The 1.3% difference between footwear identified here most likely stemmed from the difference in shoe mass considering that the Cr difference was independent of slope gradient and that the between-footwear kinematic alterations with slope provided limited explanations.

sted, utgiver, år, opplag, sider
2013. Vol. 23, nr 4, s. e246-e253
Emneord [en]
Energy expenditure, Kinematics, Oxygen consumption, Running, Shoes
HSV kategori
Identifikatorer
URN: urn:nbn:se:miun:diva-19929DOI: 10.1111/sms.12057ISI: 000321760100006Scopus ID: 2-s2.0-84880512625OAI: oai:DiVA.org:miun-19929DiVA, id: diva2:655161
Tilgjengelig fra: 2013-10-10 Laget: 2013-09-25 Sist oppdatert: 2025-09-25bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Fabre, NicolasHébert-Losier, Kim

Søk i DiVA

Av forfatter/redaktør
Fabre, NicolasHébert-Losier, Kim
Av organisasjonen
I samme tidsskrift
Scandinavian Journal of Medicine and Science in Sports

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 939 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf