Mid Sweden University

miun.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A test to assess aerobic and anaerobic parameters during maximal exercise in young girls
Mittuniversitetet, Fakulteten för humanvetenskap, Institutionen för hälsovetenskap. (Swedish Winter Sports Research Centre)
Univ Lille, Fac Sports Sci & Phys Educ, Lab Human Movement Studies, Ronchin, France.
Univ Brighton, Chelsea Sch Res Ctr, Eastbourne, England.
Univ Brighton, Chelsea Sch Res Ctr, Eastbourne, England.
Vise andre og tillknytning
2012 (engelsk)Inngår i: Pediatric Exercise Science, ISSN 0899-8493, E-ISSN 1543-2920, Vol. 24, nr 2, s. 262-274Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The Wingate cycle test (WAnT) is a 30-s test commonly used to estimate anaerobic work capacity (AWC). However, the test may be too short to fully deplete anaerobic energy reserves. We hypothesized that a 90-s all-out isokinetic test (ISO_90) would be valid to assess both aerobic and anaerobic capacities in young females. Eight girls (11.9 ± 0.5 y) performed an exhaustive incremental test, a WAnT and an ISO_90. Peak VO2 attained during the ISO_90 was significantly greater than VO2peak. Mean power, end power, fatigue index, total work done and AWC were not significantly different between the WAnT and after 30 s of the 90-s test (i.e., ISO_30). However, 95% limits of agreement showed large variations between the two tests when comparing all anaerobic parameters. It is concluded that an ISO-90 may be a useful test to assess aerobic capacity in young girls. However, since the anaerobic parameters derived from the ISO_30 did not agree with those derived from a traditional WAnT, the validity of using an ISO_90 to assess anaerobic performance and capacity within this population group remains unconfirmed.

sted, utgiver, år, opplag, sider
2012. Vol. 24, nr 2, s. 262-274
Emneord [en]
aerobic and anaerobic work capacity, Wingate test, 90-s isokinetic test, methodology
HSV kategori
Identifikatorer
URN: urn:nbn:se:miun:diva-16377ISI: 000304743100009Scopus ID: 2-s2.0-84863475653OAI: oai:DiVA.org:miun-16377DiVA, id: diva2:531636
Tilgjengelig fra: 2012-06-07 Laget: 2012-06-07 Sist oppdatert: 2025-09-25bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Scopus

Person

McGawley, Kerry

Søk i DiVA

Av forfatter/redaktør
McGawley, Kerry
Av organisasjonen
I samme tidsskrift
Pediatric Exercise Science

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 424 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf