Mid Sweden University

miun.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Multi Channel Array Interferometer-Fourier Spectrometer
(STC)
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för informationsteknologi och medier.
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för informationsteknologi och medier.
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för informationsteknologi och medier.ORCID-id: 0000-0002-3790-0729
Ansvarlig organisasjon
2006 (engelsk)Inngår i: 2006 Northern Optics Conference Proceedings, New York: IEEE , 2006, s. 1-6Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

The characterization and design of a Fourier transform spectrometer, which enables the integration of a multi channel interferometer with a detector unit in order to create a compact device is presented in this paper. It operates within a wide spectral range from visible to NIR, contains no moving parts and is resistible to mechanical and climatic conditions. Such a design with an array or matrix detector can be used for spectroscopy with a partially coherent or white optical source depending on the shape of the optical interferometer. A reasonable spectral resolution of the order of 20-50 cm-1 can be achieved over a 1 µm wavelength range when using a 512 pixel detector array. A design model for characterization of the quasi integrated device, where a multi channel interferometer was mechanically attached and which contained a gap to the detector elements, was used. The experimental results are promising and suggest a variety of different directions for the development and application of these types of integrated spectrometers.

sted, utgiver, år, opplag, sider
New York: IEEE , 2006. s. 1-6
Emneord [en]
Fabry-Perot interferometers, Fourier spectroscopy, Optical spectroscopy, Spectroscopy
HSV kategori
Identifikatorer
URN: urn:nbn:se:miun:diva-3539ISI: 000245891100001Lokal ID: 4209ISBN: 978-1-4244-0435-3 (tryckt)OAI: oai:DiVA.org:miun-3539DiVA, id: diva2:28571
Konferanse
3rd Northern Optics Conference, Jun 14-16, 2006, Bergen, Norway
Prosjekter
STC - Sensible Things that CommunicateTilgjengelig fra: 2008-12-11 Laget: 2008-12-10 Sist oppdatert: 2025-09-25bibliografisk kontrollert
Inngår i avhandling
1. Development of Process Technology for Photon Radiation Measurement Applications
Åpne denne publikasjonen i ny fane eller vindu >>Development of Process Technology for Photon Radiation Measurement Applications
2007 (engelsk)Licentiatavhandling, med artikler (Annet vitenskapelig)
Abstract [en]

This thesis presents work related to new types of photo detectors and their applications. The focus has been on the development of process technology and methods by means of experimentation and measurements. The overall aim has been to develop and improve photon radiation measurement applications which are possible to manufacture using standard Si processing technology.

A new type of position sensitive detector that has switching possibilities based on the MOS principle has been fabricated and characterized. The influence of mechanical stress on the linearity of position sensitive detectors has been investigated. The results show that mechanical stress arising, for example, by the mounting of detectors in capsules can have an impact on device performance. Under normal circumstances these effects are rather small, but are considered to be worthwhile taking into account.

Electroless deposition of Nickel including various dopants in porous silicon was performed to manufacture electrical contacts for this interesting material. After heat treatment it was confirmed by X-ray diffraction that Nickel silicide had been formed and I-V measurements show that different contacts exhibit Ohmic and rectifying behaviour.

Spectrometers are used extensively in the process and food industry to measure both the chemical content and the amount of substances used during manufacturing. These instruments are often rather bulky and costly, though the trend is towards smaller and more portable equipment. A spectrometer based on an array of Fabry-Perot interferometers mounted close to an array detector is shown to be a viable option for the manufacture of a very compact device. Such a device has minimal intermediate optics and it may be possible, in the future, for it to be developed and completely integrated with a detector array into a single unit.

sted, utgiver, år, opplag, sider
Sundsvall: Mittuniversitetet, 2007. s. 42
Serie
Mid Sweden University licentiate thesis, ISSN 1652-8948 ; 16
HSV kategori
Identifikatorer
urn:nbn:se:miun:diva-9334 (URN)91-85317-32-2 (ISBN)
Presentation
(engelsk)
Opponent
Veileder
Tilgjengelig fra: 2009-07-10 Laget: 2009-07-10 Sist oppdatert: 2025-09-25bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Person

Manuilskiy, AnatoliyAndersson, HenrikThungström, GöranNilsson, Hans-Erik

Søk i DiVA

Av forfatter/redaktør
Manuilskiy, AnatoliyAndersson, HenrikThungström, GöranNilsson, Hans-Erik
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 1022 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf