Factors influencing the determination of analyte ion surface partitioning coefficients in electrosprayed droplets
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för naturvetenskap.ORCID-id: 0000-0002-3646-294X
2001 (engelsk)Inngår i: Journal of the American Society for Mass Spectrometry, ISSN 1044-0305, Vol. 12, nr 9, s. 1002-1010Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The observed response in mass spectrometry utilizing electrospray as a sample introduction technique can be affected by a number of factors. In this study a series of two-electrolyte systems was investigated and the mass spectrometric responses were modeled by the use of droplet surface partitioning coefficients and instrumental response factors according to a recently reported method (Sjo¨berg et al., Anal. Chem. 2001, 73, 23–28). The partitioning coefficient and the instrumental response factor were found to be affected by the chosen experimental conditions. Experimental parameters that were investigated include spray position relative to the orifice, spray potential, nebulizer and curtain gas flow rates, ionic strength, and organic content of the sprayed solution. The time history of the generated droplets turned out to be of importance to both the partitioning coefficients and the instrumental response factor. For example, a general increase in the surface partitioning coefficients for the tetrapentylammonium ion was initially observed when the spray was aiming closer to the sampling orifice. Furthermore, it was shown with a small amount of deuterium labeled electrolyte that the total ionic strength and not just the electrolyte concentration influence the instrumental response factor. (J Am Soc Mass Spectrom 2001, 12, 1002–1010)

sted, utgiver, år, opplag, sider
2001. Vol. 12, nr 9, s. 1002-1010
Emneord [en]
electrospray ionization
HSV kategori
Identifikatorer
URN: urn:nbn:se:miun:diva-2521DOI: 10.1016/S1044-0305(01)00281-1Lokal ID: 1777OAI: oai:DiVA.org:miun-2521DiVA, id: diva2:27553
Tilgjengelig fra: 2008-09-30 Laget: 2008-09-30 Sist oppdatert: 2025-09-25bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Person

Bylund, Dan

Søk i DiVA

Av forfatter/redaktør
Bylund, Dan
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 198 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf