Mid Sweden University

miun.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Improving Cardiac Auscultation Signal Quality by using 4-Channel Stethoscope Array
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för data- och elektroteknik (2023-). (STC)ORCID-id: 0000-0001-7410-0483
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för data- och elektroteknik (2023-). (STC)ORCID-id: 0000-0002-8253-7535
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för data- och elektroteknik (2023-). (STC)ORCID-id: 0000-0002-7213-7626
Vise andre og tillknytning
2024 (engelsk)Inngår i: Conference Record - IEEE Instrumentation and Measurement Technology Conference, IEEE conference proceedings, 2024Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

In cardiac auscultation, the ability to clearly hear any existing murmur sounds in heart sounds is crucial for proper diagnosis. This work aims to improve heart sound by the use of a stethoscope array and beamforming technique. The stethoscope array comprises four piezo elements for measurement, placed on the edges of a 40mm by 40mm rectangle. The directionality of the piezo elements reduces the effect of ambient noise in the measurement. The signal amelioration is achieved by isolating the systole and diastole sounds, and independently applying the delay-and-sum beamforming. This thereby makes any existing murmur sounds in the systole and/or diastole more audible and clearer to aid diagnosis. Finally, the designed stethoscope array and signal processing shows a gain of up to 33% for measured healthy heart samples, and up to 63% increase in murmur sound gain for measured sample with medically confirmed murmur. 

sted, utgiver, år, opplag, sider
IEEE conference proceedings, 2024.
Emneord [en]
acoustic beam steering, auscultation, auscultation signal processing, stethoscope, stethoscope array
HSV kategori
Identifikatorer
URN: urn:nbn:se:miun:diva-52055DOI: 10.1109/I2MTC60896.2024.10560871ISI: 001261521400174Scopus ID: 2-s2.0-85197746698ISBN: 9798350380903 (tryckt)OAI: oai:DiVA.org:miun-52055DiVA, id: diva2:1887325
Konferanse
Conference Record - IEEE Instrumentation and Measurement Technology Conference
Tilgjengelig fra: 2024-08-07 Laget: 2024-08-07 Sist oppdatert: 2026-01-26bibliografisk kontrollert
Inngår i avhandling
1. Measurement Quality in Acoustic Sensing with Microphones: From Indoor Localization to Heart Sound Classification
Åpne denne publikasjonen i ny fane eller vindu >>Measurement Quality in Acoustic Sensing with Microphones: From Indoor Localization to Heart Sound Classification
2026 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

This thesis investigates how measurement design shapes acoustic source localization and classification, with a focus on the interplay between array geometry, device characteristics, and modern signal processing and deep learning. The work is motivated by a persistent gap between theoretically well-understood methods and the practical realities of indoor positioning and biomedical auscultation, where sensor variability, reverberation, and limited control over operating conditions often dominate performance. The overarching aim is to understand how measurement quality in microphone-based sensing constrains and enables what can be inferred from sound under real-world noise, by treating microphones, arrays, and recording protocols as design variables rather than static background assumptions.

Six studies (P1–P6 refer to the list of papers) are presented. The first line of work concerns acoustic fingerprinting. P1 examines how far a single microphone can exploit ambient noise for indoor “silent” object localization, highlighting both the appeal of zero-emission fingerprints and their sensitivity to day-to-day room changes. P6 revisits fingerprinting with active excitation, using exponential sine sweeps and a four-microphone array feeding a convolutional neural network. The comparison between P1 and P6 shows how moving from uncontrolled ambient sound to controlled probing and array-based features improves robustness. Together, they characterize a practical design space for silent object localization, from simple cross-correlation baselines to array-aided deep learning.

The second line of work addresses direction-of-arrival (DoA) estimation with microphone arrays. P2 compares several planar layouts and microphone directivities in a controlled room, using a representative high-resolution DoA estimator to isolate how geometry and sensor pattern affect accuracy and robustness in realistic indoor conditions. P3 focuses on a six-channel uniform circular array and a coherent wideband pipeline, showing that circular-harmonic focusing can retain MUSIC-level resolution while keeping computational demands compatible with embedded implementations. These studies map how established methods behave when constrained by physically small arrays and practical sensor choices, clarifying when geometry or processing is the main bottleneck.

A third line of work turns to biomedical acoustic classification. P4 evaluates a four-channel electronic stethoscope prototype that combines delay-and-sum beamforming and matched filtering for heart-sound segmentation before classification. Working with a limited and clinically constrained dataset, the study illustrates how a realistic multi-channel auscultation setup can increase segment quality and support distinguish normal and abnormal sound for murmur detection. Finally, the thesis examines measurement quality more generally. P5 introduces a measurement quality pipeline that uses existing recordings to extrapolate the benefit of future system upgrades. By fixing a pretrained CNN and synthetically degrading current data to different SNR levels, the study emulates the performance of improved setups, providing a basis for deciding whether it is worthwhile to invest in new measurements and a full round of model retraining and tuning. These results underline that model architecture and measurement quality jointly determine performance, and that metrological upgrades can sometimes deliver rich information without retraining.

Overall, the thesis contributes a set of measurement-driven case studies that make explicit how arrays, excitation signals, and device responses constrain what localization and classification algorithms can realistically achieve. The outcomes include practical recipes for acoustic fingerprinting, design reference points for compact array configurations in indoor DoA tasks, an experimentally grounded path toward reproducible multi-channel auscultation, and empirical guidelines for anticipating how SNR and device variability affect pretrained models. Rather than resolving all trade-offs, the work argues for treating measurement design and algorithm choice as coupled problems.

sted, utgiver, år, opplag, sider
Sundsvall: Mid Sweden University, 2026. s. 67
Serie
Mid Sweden University doctoral thesis, ISSN 1652-893X ; 446
HSV kategori
Identifikatorer
urn:nbn:se:miun:diva-56463 (URN)978-91-90017-57-9 (ISBN)
Disputas
2026-02-25, M108, Holmgatan 10, Sundsvall, 09:00 (engelsk)
Opponent
Veileder
Merknad

Vid tidpunkten för disputationen var följande delarbeten opublicerade: delarbete 6 accepterat.

At the time of the doctoral defence the following papers were unpublished: paper 6 accepted.

Tilgjengelig fra: 2026-01-28 Laget: 2026-01-26 Sist oppdatert: 2026-01-28bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Adamopoulou, MarianthiJiang, MengNnonyelu, Chibuzo JosephLundgren, Jan

Søk i DiVA

Av forfatter/redaktør
Adamopoulou, MarianthiJiang, MengNnonyelu, Chibuzo JosephLundgren, Jan
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 199 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf