Mid Sweden University

miun.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Characterization of area sensitivity in 55 um pixellated CdTe X-ray imaging detectors
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för informationsteknologi och medier. (STC)ORCID-id: 0000-0002-8325-5177
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Institutionen för informationsteknologi och medier. (STC)
Czech Technical University, Prague, Czech Republic.
Czech Technical University, Prague, Czech Republic.
Vise andre og tillknytning
2007 (engelsk)Inngår i: IEEE Nuclear Science Symposium Conference Record, New York: IEEE conference proceedings, 2007, s. 1234-1236Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

X-ray imaging detectors with energy resolution, based on a single photon processing CMOS readout circuit attached to a detector chip, are being developed by different groups. In order to achieve high quantum efficiency it is preferable to use high-Z semiconductor materials. However the fluorescent X-ray photons of such materials have high energies and are able to travel long distances thereby reducing both the spatial resolution and the energy resolution of the detector. In addition charge sharing in the detector and non-uniformities in both the detector and the readout electronics will affect the signal. In this work we have characterized a 1 mm thick CdTe detector with a pixel size of 55 um x 55 um, bump bonded to the MEDIPIX2 single photon processing readout chip. The area sensitivity of the detector is evaluated using a narrow X-ray beam of monoenergetic photons. From these measurements the effects of fluorescence and charge sharing can be evaluated.

sted, utgiver, år, opplag, sider
New York: IEEE conference proceedings, 2007. s. 1234-1236
Emneord [en]
Medipix, CdTe, X-ray, imaging
HSV kategori
Identifikatorer
URN: urn:nbn:se:miun:diva-7625DOI: 10.1109/NSSMIC.2007.4437227ISI: 000257380400257Scopus ID: 2-s2.0-48349133078Lokal ID: 5460ISBN: 978-1-4244-0922-8 (tryckt)OAI: oai:DiVA.org:miun-7625DiVA, id: diva2:127875
Konferanse
IEEE Nuclear Science Symposium/Medical Imaging Conference, Oct 26-Nov 03, 2007, Honolulu
Tilgjengelig fra: 2008-12-11 Laget: 2008-12-10 Sist oppdatert: 2025-09-25bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Fröjdh, ChristerNorlin, BörjeFröjdh, AnnaFröjdh, Erik

Søk i DiVA

Av forfatter/redaktør
Fröjdh, ChristerNorlin, BörjeFröjdh, AnnaFröjdh, Erik
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 819 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf