Mid Sweden University

miun.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
High Precision Laser Scanning of Metallic Surfaces
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Avdelningen för elektronikkonstruktion.
Mittuniversitetet, Fakulteten för naturvetenskap, teknik och medier, Avdelningen för elektronikkonstruktion.
2017 (engelsk)Inngår i: International Journal of Optics, ISSN 1687-9384, E-ISSN 1687-9392, artikkel-id 4134205Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Speckle noise, dynamic range of light intensity, and spurious reflections are major challenges when laser scanners are used for 3D surface acquisition. In this work, a series of image processing operations, that is, Spatial Compound Imaging, High Dynamic Range Extension, Gray Level Transformation, and Most Similar Nearest Neighbor are proposed to overcome the challenges coming from the target surface. A prototype scanner for metallic surfaces is designed to explore combinations of these image processing operations. The main goal is to find the combination of operations thatwill lead to the highest possible robustness andmeasurement precision at the lowest possible computational load. Inspection of metallic tools where the surface of its edge must be measured at micrometer precision is our test case. Precision of heights measured without using the proposed image processing is firstly analyzed to be +/- 7.6 mu m at 68% confidence level. The best achieved height precision was +/- 4.2 mu m. This improvement comes at 24 times longer processing time and five times longer scanning time. Dynamic range extension of the image capture improves robustness since the numbers of saturated or underexposed pixels are substantially reduced. Using a high dynamic range (HDR) camera offers a compromise between processing time, robustness, and precision.

sted, utgiver, år, opplag, sider
2017. artikkel-id 4134205
HSV kategori
Identifikatorer
URN: urn:nbn:se:miun:diva-31363DOI: 10.1155/2017/4134205ISI: 000405332500001Scopus ID: 2-s2.0-85024488897OAI: oai:DiVA.org:miun-31363DiVA, id: diva2:1130524
Tilgjengelig fra: 2017-08-10 Laget: 2017-08-10 Sist oppdatert: 2025-09-25bibliografisk kontrollert

Open Access i DiVA

fulltext(3696 kB)1189 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 3696 kBChecksum SHA-512
df5351df717af2fa19d0240abf03b47db90944073374f9d9d65571edeb5de78bf5ab026304e2870b61771c75f60ca3daaafacbe3f7012770be33836379840394
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstScopus

Person

Amir, Yousaf MuhammadThörnberg, Benny

Søk i DiVA

Av forfatter/redaktør
Amir, Yousaf MuhammadThörnberg, Benny
Av organisasjonen
I samme tidsskrift
International Journal of Optics

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 1191 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 771 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf