Hur påverkar olinjära laster en reservkraftsgenerator?
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.
2016 (Swedish)Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Datahallar behöver reservkraft av god kvalitet för att garantera upprätthållandet av dess funktion. Laster i en datahall kommer att generera ström och spänningsövertoner som kan skapa problematik med elkvaliteten. Coromatic är intresserade av att veta mer hur dessa laster påverkar reservkraftsgeneratorn. En mätning utfördes på en datahall under ett funktionsprov. Resultatet blev att halten av THD ökade, främst är det 3:e övertonen som är framträdande. Mätvärdena för THDV ligger under gränsvärdena för SS-EN 50160 och 61000-2-2, men gränsvärdena för 3:e ton ligger långt över. Ingen åtgärd föreslås i nuläget för att hantera problemet. Denna avhandling har gett värdefull information till Coromatic att ta i beaktande vid utförande av nya reservkraftsanläggningar.

Abstract [en]

A facility full with computers needs backup-power to guarantee the function. Loads in this facility will produce current and voltage harmonics that can pollute and cause trouble with the quality of electricity. Coromatic are interested in knowing more about how these loads can affect the generator. A measurement was performed on a facility when they ran a functional test. The results indicated that THD increased, the third harmonic turned out to be the single harmonic with the highest value. The value is within the boundaries for THDV according to SS-EN 50160 and 61000-2-2, except for the third harmonic. Its value was far too high. No action is propsed to deal with the problem at the moment. This thesis has provided Coromatic with valuable information too consider when they building new systems.

Place, publisher, year, edition, pages
2016. , p. 70
Keywords [en]
Evaluation, non-linear load, harmonics, backup-power, datacenter
Keywords [sv]
Utvärdering, olinjära laster, övertoner, reservkraft, datorhall
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:miun:diva-28318Local ID: ET-V16-G3-006OAI: oai:DiVA.org:miun-28318DiVA, id: diva2:946284
Subject / course
Electrical Engineering ET2
Educational program
Electric Power Engineering TEKRG 180 higher education credits
Supervisors
Examiners
Available from: 2016-07-05 Created: 2016-07-05 Last updated: 2016-07-05Bibliographically approved

Open Access in DiVA

fulltext(12885 kB)533 downloads
File information
File name FULLTEXT01.pdfFile size 12885 kBChecksum SHA-512
2248578341385425da1a2b9e1d97601ba0e630fb0a171de8b4581291d04d4e879ef8958d0e29386f5f1c5a9c90ae05499e846b5f8e6a76ddc4c7e6062b4a45ea
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Bäckman, Fredrik
By organisation
Department of Electronics Design
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 533 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1340 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf