Front end ASIC for AGIPD, a high dynamic range fast detector for the European XFELPaul Scherrer Inst, CH-5232 Villigen, Switzerland.
Deutsch Elekt Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany.
Deutsch Elekt Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany.
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design. Deutsch Elekt Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany.
Paul Scherrer Inst, CH-5232 Villigen, Switzerland.
Deutsch Elekt Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany.
Deutsch Elekt Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany.
Univ Hamburg, Mittelweg 177, D-20148 Hamburg, Germany.
Deutsch Elekt Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany.
Univ Bonn, D-53012 Bonn, Germany.
Deutsch Elekt Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany.
Deutsch Elekt Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany.
Paul Scherrer Inst, CH-5232 Villigen, Switzerland.
Paul Scherrer Inst, CH-5232 Villigen, Switzerland.
Deutsch Elekt Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany.
Deutsch Elekt Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany.
Deutsch Elekt Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany.
Paul Scherrer Inst, CH-5232 Villigen, Switzerland.
Univ Hamburg, Mittelweg 177, D-20148 Hamburg, Germany.
Deutsch Elekt Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany.
Paul Scherrer Inst, CH-5232 Villigen, Switzerland.
Deutsch Elekt Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany.
Deutsch Elekt Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany.
Deutsch Elekt Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany.
Deutsch Elekt Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany.
Show others and affiliations
2016 (English)In: Journal of Instrumentation, E-ISSN 1748-0221, Vol. 11, no 1, article id C01057Article in journal (Refereed) Published
Resource type
Text
Abstract [en]
The Adaptive Gain Integrating Pixel Detector (AGIPD) is a hybrid pixel X-ray detector for the European-XFEL. One of the detector's important parts is the radiation tolerant front end ASIC fulfilling the European-XFEL requirements: high dynamic range-from sensitivity to single 12.5keV-photons up to 104 photons. It is implemented using the dynamic gain switching technique with three possible gains of the charge sensitive preamplifier. Each pixel can store up to 352 images in memory operated in random-access mode at >= 4.5MHz frame rate. An external vetoing may be applied to overwrite unwanted frames.
Place, publisher, year, edition, pages
2016. Vol. 11, no 1, article id C01057
Keywords [en]
Front-end electronics for detector readout, X-ray detectors, VLSI circuits, Radiation-hard electronics
National Category
Electrical Engineering, Electronic Engineering, Information Engineering Accelerator Physics and Instrumentation
Identifiers
URN: urn:nbn:se:miun:diva-27819DOI: 10.1088/1748-0221/11/01/C01057ISI: 000371469800057Scopus ID: 2-s2.0-84956903138Local ID: STCOAI: oai:DiVA.org:miun-27819DiVA, id: diva2:934242
Conference
Topical Workshop on Electronics for Particle Physics, SEP 28-OCT 02, 2015, Lisbon, PORTUGAL
2016-06-082016-06-072024-07-04Bibliographically approved