A first comparison of the responses of a He-4-based fast-neutron detector and a NE-213 liquid-scintillator reference detectorShow others and affiliations
2015 (English)In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN 0168-9002, E-ISSN 1872-9576, Vol. 794, p. 102-108Article in journal (Refereed) Published
Abstract [en]
A first comparison has been made between the pulse-shape discrimination characteristics of a novel He-4-based pressurized scintillation detector and a NE-213 liquicl-scintillator reference detector using an Am/Be mixed-field neutron and gamma-ray source and a high-resolution scintillation-pulse digitizer. In particular, the capabilities of the two fast neutron detectors to discriminate between neutrons and gamma-rays were investigated. The NE-213 liquicl-scintillator reference cell produced a wide range of scintillation-light yields in response to he gamma-ray field of the source. In stark contrast, clue to the size and pressure of the He-4 gas volume, the He-4-based detector registered a maximum scintillation-light yield of 750 keV(ee) to the same gamma-ray field. Pulse-shape discrimination for particles with scintillation-light yields of more than 750 keV(ee) was excellent in the case of the He-4-based detector. Above 750 keV(ee) its signal was unambiguously neutron, enabling particle identification based entirely upon the amount of scintillation light produced. (C) 2015 The Authors. Published by Elsevier B.V.
Place, publisher, year, edition, pages
2015. Vol. 794, p. 102-108
Keywords [en]
He-4, NE-213, Scintillation, Gamma-rays, Fast neutrons, Pulse-shape discrimination
National Category
Physical Sciences Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:miun:diva-25657DOI: 10.1016/j.nima.2015.04.058ISI: 000356356100014Scopus ID: 2-s2.0-84930673182OAI: oai:DiVA.org:miun-25657DiVA, id: diva2:849381
2015-08-282015-08-182017-12-04Bibliographically approved