Principle of FT Spectrometer based on a Lateral Effect Position Sensitive Detector and Multi Channel Fabry-Perot Interferometer
Mid Sweden University, Faculty of Science, Technology and Media, Department of Information Technology and Media. (Electronics design division)
Mid Sweden University, Faculty of Science, Technology and Media, Department of Information Technology and Media. (STC)
Mid Sweden University, Faculty of Science, Technology and Media, Department of Information Technology and Media. (Electronics design division, STC)
SiTek Electro Opt, S-43330 Partille, Sweden.
Show others and affiliations
2009 (English)In: Measurement, ISSN 0263-2241, E-ISSN 1873-412X, Vol. 42, no 5, 668-671 p.Article in journal (Refereed) Published
Abstract [en]

The principle of a new type of multi channel Fourier-Transform spectrometer based on a multi channel wedge Fabry-Perot interferometer using a one dimensional lateral effect Position Sensitive Detector and a scanning slit for interferogram readout have been shown. The design of this spectrometer is very compact and the readout electronics very simple. The drawback of using a scanning slit system is minimized by the use of a position sensitive detector where the position is inherently known for each measurement. Experiments show that the position can be resolved with high accuracy and the summation of the two photocurrents gives the interferogram after scanning the slit between the wedge interferometer and the position sensitive detector. The spectral resolution obtained with a 25mm wedge interferometer together with a 45mm position sensitive detector and a 25µm slit is about 5nm around 600nm wavelength range, which is close to the theoretically anticipated resolution. The evaluated spectrometer setup show promising results and could be used in applications where compact and low cost spectrometers are required.

Place, publisher, year, edition, pages
2009. Vol. 42, no 5, 668-671 p.
Keyword [en]
Spectrometer, FT, position sensitive detector, PSD, Fabry-Perot interferometer
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:miun:diva-6460DOI: 10.1016/j.measurement.2008.11.004ISI: 000265776400004Scopus ID: 2-s2.0-63749109798Local ID: 5076OAI: oai:DiVA.org:miun-6460DiVA: diva2:31499
Projects
STC - Sensible Things that Communicate
Available from: 2008-12-10 Created: 2008-11-19 Last updated: 2016-10-05Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Andersson, HenrikManuilskiy, AnatoliyThungström, GöranNilsson, Hans-Erik
By organisation
Department of Information Technology and Media
In the same journal
Measurement
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

Altmetric score

Total: 485 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf