miun.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Fabrication and characterization of a design optimized SU-8 thermopile with enhanced sensitivity
Mid Sweden University, Faculty of Science, Technology and Media, Department of Information Technology and Media. (Electronics design division, STC)
Mid Sweden University, Faculty of Science, Technology and Media, Department of Information Technology and Media. (Electronics design division)
Mid Sweden University, Faculty of Science, Technology and Media, Department of Information Technology and Media. (Electronics design division)
Mid Sweden University, Faculty of Science, Technology and Media, Department of Information Technology and Media. (Electronics design division)ORCID iD: 0000-0002-3790-0729
Show others and affiliations
2009 (English)In: Measurement science and technology, ISSN 0957-0233, E-ISSN 1361-6501, Vol. 20, no 11, p. 115202-Article in journal (Refereed) Published
Abstract [en]

In the infrared wavelength region, thermopiles are an important type of detectors. A major advantage of thermopiles is their non-cooling requirement. Depending on the applied absorption layer, their responsivity is often rather flat within a large wavelength region. This work presents the fabrication and characterization of a sensitivity and design optimized thermopile detector with a 4 µm self-supported SiO2/SU-8 membrane. The structure consists of 240 series interconnected thermocouple junctions obtained by a metal evaporation and lift-off. Two metal combinations have been evaluated, namely, nickel/titanium and aluminium/bismuth. Series resistances of 76 k and 283 k were measured for the Ni/Ti thermopile and the Al/Bi thermopile respectively. For the Al/Bi thermopile a responsivity of 60 V/W was achieved using a 1.56 µm fibre coupled diode laser with a power of 3.5 mW. Using a white light source with a radiation flux of 0.45 W/mm2 a voltage response of 68 V mm2/W was measured for the Al/Bi thermopile. The time constant of the characterized detectors was calculated as being 70 ms, using the pulsed IR laser.

Place, publisher, year, edition, pages
IOP , 2009. Vol. 20, no 11, p. 115202-
Keywords [en]
Fabrication, Thermopile, SU-8
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:miun:diva-8829DOI: 10.1088/0957-0233/20/11/115202ISI: 000270988800022Scopus ID: 2-s2.0-70350691206OAI: oai:DiVA.org:miun-8829DiVA, id: diva2:213816
Conference
6th International Symposium on Measurement Techniques for Multiphase Flows, Dec 15-17, 2008, Okinawa, Japan
Projects
STC - Sensible things that communicate
Note
6th International Symposium on Measurement Techniques for Multiphase Flows, DEC 15-17, 2008, Okinawa, JapanAvailable from: 2009-04-29 Created: 2009-04-29 Last updated: 2017-12-13Bibliographically approved
In thesis
1. Design, Fabrication and Optimization of Thermal Radiation Detectors Based on Thin Polymer Membranes
Open this publication in new window or tab >>Design, Fabrication and Optimization of Thermal Radiation Detectors Based on Thin Polymer Membranes
2009 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

The number of applications in which infrared radiation sensors are used is increasing. In some applications, the cost of the sensor itself is an issue, and simple solutions are thus required. In this thesis, the investigations have related to the use of thin polymer membranes in thermal infrared sensors, such as bolometers and thermopiles.

Infrared sensors are usually subcategorized into photonic sensors and thermal sensors. For detection of infrared radiation using a photodetector, there is a requirement for low band-gap material. The need of cooling makes infrared photodetectors rather expensive, and not an alternative for low-cost applications. In thermal sensors, the heat generated from the incident infrared radiation is converted into an electrical output by means of a heat sensitive element. Thermal sensors operate at room temperature, which makes them a low-cost alternative. The basic structure of thermal sensors consists of a temperature sensitive element connected to a heat sink through a structure with low thermal conductance. It is common to use thin membranes of Silicon or Silicon Nitride as thermal insulation between the heat sink and the sensitive element. In comparison, polymers have a thermal conductance that is lower than in these materials, and this increases the generated temperature in the sensitive element. A polymer such as SU-8 has a low thermal conductivity and is applied using a spin coater. This reduces the number of complex processing steps. This thesis presents a new application of SU-8 as a closed membrane in a thermal sensor.

The concept was initially demonstrated by fabricating a nickel bolometer and titanium/nickel thermopile structure with a 5 µm SU-8 / SiO2 membrane. However, for the sensor responsivity to be able to compete with commercial thermal sensors the structures, some optimization was required. Since the thermopile generates its own voltage output and requires no external bias, the optimizations were focused on this structure. There exist a number available software tools for thermal simulation of components. However, to the author’s best knowledge, there exist no tool for design optimization of thermopiles with closed membranes. An optimization tool using iterative thermal simulations was developed and evaluated. A new thermopile structure, based on the optimization results, was both fabricated and characterized. Using an infrared laser with a small spot, the measured responsivity of the manufactured thermopile was higher than that of a commercial sensor. In the case of a defocused spot and for longer wavelengths, the infrared absorption in the absorption layer reduces and degrades the responsivity.

The thermopile was further evaluated as a sensor in a carbon dioxide meter application based on the NDIR principle. An increase in the CO2 concentration demonstrated a clear decrease in the thermopile voltage response, as was expected. By normalizing the voltage response and comparing it with a commercial sensor, this showed that the SU-8 based thermopile is relatively more sensitive to changes in the CO2 concentration.

Place, publisher, year, edition, pages
Sundsvall: Kopieringen Mittuniversitetet, 2009. p. 64
Series
Mid Sweden University doctoral thesis, ISSN 1652-893X ; 73
Keywords
Thermal detector, Polymer, Membrane, SU-8
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:miun:diva-9579 (URN)978-91-86073-46-6 (ISBN)
Public defence
2009-09-19, O111, Holmgatan 10, Sundsvall, 13:15 (English)
Opponent
Supervisors
Projects
STC
Available from: 2009-08-28 Created: 2009-08-27 Last updated: 2011-02-06Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records BETA

Mattsson, ClaesThungström, GöranBertilsson, KentNilsson, Hans-Erik

Search in DiVA

By author/editor
Mattsson, ClaesThungström, GöranBertilsson, KentNilsson, Hans-Erik
By organisation
Department of Information Technology and Media
In the same journal
Measurement science and technology
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 927 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf