Mid Sweden University

miun.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Distribution Automation System: Kommunikationsprotokoll
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.
2022 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Med den ökande efterfrågan från elkonsumenter förändrades och utökades också elnäten komplexiteten, och denna utbyggnad ökade i en sådan utsträckning att nu elnät, i termer av produktion, överföring och distribution anses vara den största konstgjorda strukturen. Vid strömavbrott, även på en liten punkt i nätet, påverkas alla delar av det, vilket leder till att det behövs noggrann övervakning av olika delar av nätet. Elektrisk energi studeras alltid på tre nivåer: produktion, transmission och distribution. För att öka produktiviteten måste el levereras till konsumenten med minimala förluster från kraftverk. En stor del av de elektriska energiförlusterna sker på distributionsnivå, vilket har lett till att distributionssektorn övervägts och sätt att öka dess effektivitet. Automatisering är ett av sätten som kan öka styrbarheten i distributionsnätet genom att övervaka distributionsnätet. Den föreliggande examensarbete med titeln "Distribution Automation Systems" försöker introducera detta system, och särskild kommunikationsprotokollen på en viss nivå och studera dess egenskaper. Detta projekt undersöker de föreslagna protokollen för automationssystem för kraftdistributionsnätverk baserade på SCADA fjärrinformationsinsamling och kontrollövervakning. Samtidigt som vikten av protokollval i dessa system påpekas, introduceras funktionerna och skillnaderna hos Modbus, Profibus, DNP3, IEC 60870, IEC 62351 och IEC 61850-protokollen. En enkät skickades också ut till sex stycken utvalda både elnätsföretagen och företagen som sysslar med elindustri. Det kan vara i form av elnäts kommunikationsprotokoll och automatisering. Två av de tillfrågade svarade och svaren har sammanställts i den här rapporten. Genom att undersöka de frågor som tas upp i distributionsnäten och de olika förhållandena, samt genom att nämna skäl som prestanda, enkelhet och support, kommer det att visas att, ett lämpligt alternativ bland de befintliga kommunikation protokollen inom detta område är IEC 61850 som också används i Sverige.

Abstract [en]

With the increasing demand from electricity consumers, the complexity of electricity networks also changed and expanded, and this expansion increased to such an extent that now electricity networks, in terms of pro-duction, transmission and distribution are the largest artificial structure. In the event of a power failure, even at a small point in the network, all parts of it are affected, which leads to the need for close monitoring of different parts of the network. Electrical energy is always studied at three levels: production, transmission and distribution. To increase productiv-ity, electricity must be delivered to the consumer with minimal losses from power plants. A large part of the electrical energy losses occurs at the distribution level, which has led to the distribution sector being con-sidered and ways of increasing its efficiency. Automation is one of the ways that can increase the controllability of the distribution network by monitoring the distribution network. The present thesis entitled "Distri-bution Automation Systems" tries to introduce this system, and special communication protocols at a certain level and study its properties. This project examines the proposed protocols for power distribution network automation systems based on SCADA remote information collection and control monitoring. At the same time as the importance of protocol selec-tion in these systems is pointed out, the functions and differences of the Modbus, Profibus, DNP3, IEC 60870, IEC 62351 and IEC 61850 protocols are introduced. A questionnaire was also sent out to six selected both elec-tricity network companies and companies engaged in the electricity in-dustry. This can be in the form of electricity network communication pro-tocols and automation. Two of the respondents and the answers have been compiled in this report. By examining the issues raised in the distri-bution networks and the different conditions, as well as by mentioning reasons such as performance, simplicity and support, it will be shown that, a suitable alternative among the existing communication protocols in this area is IEC 61850 which is also used in Sweden.

Place, publisher, year, edition, pages
2022. , p. 36
Keywords [en]
Distribution automation, Communication protocols, IEC 61850
Keywords [sv]
Distribution automation, Kommunikationsprotokoll, IEC 61850
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:miun:diva-46307OAI: oai:DiVA.org:miun-46307DiVA, id: diva2:1704648
Subject / course
Electrical Engineering ET2
Educational program
Automationsingenjör TAUMG 180 GR
Supervisors
Examiners
Available from: 2022-10-19 Created: 2022-10-19 Last updated: 2022-10-19Bibliographically approved

Open Access in DiVA

No full text in DiVA

Search in DiVA

By author/editor
Khomamizad, Amirali
By organisation
Department of Electronics Design
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 252 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf