Automatisering av pH-mätning vid plantskola
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.
2021 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Plantskolan i Friggesund önskade utveckla sitt bevattningssystem. Önskemålet var att ta fram en lösning där vattnets pH loggas samt eventuellt regleras till en konstant nivå för att säkerställa ett optimalt näringsupptag samt ett kostnadsförslag. I nuläget sker ingen mätning av pH och tillsats av gödsel sker manuellt. Målet med detta examensarbete är att kunna presentera ett kostnadsförslag samt ett förslag som med hjälp av pH-mätning kan förbättra bevattningsprocessen. Detta för att förbättra hanteringen av gödsel i bevattningsvattnet för att kunna optimera tillväxten av plantorna samt minimera utsläppen av gödningsmedel i naturen. Målet är även att detta skall kunna utgöra en grund till en bättre automatiserad anläggning där hela bevattningssystemet kan kopplas samman för att verka i symbios. I en studie utförd år 2003 visas ett samband mellan tallplantans aminosyraupptag och dess pH-beroende. Bäst upptag uppmättes vid ett pH 4–5. Två pH-givare och en temperaturgivare skall installeras i vattenledningen från vattentanken i pumprummet för att kunna mäta samt logga dessa data. För att möjliggöra datainsamlande samt framtidssäkra anläggningen togs ett kostnadsförslag fram baserat på utvärdering av befintligt styrsystem kontra ett nytt, baserad på en PLC. I resultatet presenteras ett kostnadsförslag samt flödesschema över tänkt installation. Författaren föreslår som en ytterligare vinst för plantskolan efter installation av PLC att även genomföra automatisering av frilanden genom att använda sig av jordfuktsmätare i frilandet och som ansluts till den PLC som styr bevattningen vid frilandet. Om installationen genomförs kan detta utmynna i att ytterligare forskning på området kan utföras.

Abstract [en]

A nursery garden in Friggesund requested a development in their irrigation system. The ambition was to develop a solution where the water's pH is logged and possibly regulated to a constant level to ensure optimal nutrient uptake and produce a cost proposal. There is no pH measurement for the moment and fertilizer is added manually. The aim was to present a cost proposal and a solution to measure pH that can improve the irrigation process and the management of manure in the irrigation water. The intention was to optimize the growth of the plants and minimize emissions of fertilizers in nature. The ambition was also to form a basis for a better automated plant where the entire irrigation system can be connected to operate in symbiosis. A study conducted in 2003 shows a connection between the pine plant's amino acid uptake and its dependence in an optimized pH-range of 4 to 5. It was recommended to install two pH- and a temperature sensor in the pipe from the water tank, to be able to measure and log this data. To enable data collection and to future-proof, a cost proposal was developed based on an evaluation of existing control system versus a new one based on a PLC. The result presents a cost proposal and a flow chart of the intended installation. An additional benefit for the nursery garden could be to implement automation in open land by using soil moisture meters at the plants. A performed installation may result in data that could be vital for further research in this area.

 

Place, publisher, year, edition, pages
2021. , p. 24
Keywords [en]
PLC, pH-logging, automation
Keywords [sv]
PLC, pH-loggning, automatisering
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:miun:diva-42931Local ID: ET-V21-G3-069OAI: oai:DiVA.org:miun-42931DiVA, id: diva2:1590339
Subject / course
Electrical Engineering ET2
Educational program
Automationsingenjör TAUMG 180 GR
Supervisors
Examiners
Available from: 2021-09-02 Created: 2021-09-02 Last updated: 2021-09-02Bibliographically approved

Open Access in DiVA

No full text in DiVA

Search in DiVA

By author/editor
Björklund, Lars
By organisation
Department of Electronics Design
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 222 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf