Elnätets temperaturkänslighet: En undersökning av hur utomhustemperaturens variationerpåverkar effektbehovet i Umeå Energi Elnäts elnät.
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.
2021 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

För att vara väl förberedd inför eventuella framtida kapacitetsutmaningar i elnätet ville Umeå Energi Elnät fåen bättre bild på vad variationerna hos energiförbrukningen beror på. I detta examensarbete var målet att undersöka sambandet mellan elnätets effektbehov och utomhustemperaturen samt att ta fram en modell av elnätets effektbehov. För att få en tillräckligt bra modell behövdes fler faktorer som påverkar effektbehovet användas. I modellen som arbetet resulterade i användes förutom utomhustemperaturen även månad, veckodag och tid på dygnet som variabler för att bättre kunna förutsede variationer som finns hos energiförbrukningen. Under arbetets gång upptäcktes ytterligare två faktorer som senare blev en del av modellen på grund av att de hadeen stor påverkan på resultatet. Dessa faktorer var dels ettantal större energiförbrukare, dels en del elproduktioninom Umeå Energi Elnäts elnät.Metoden som användes för att utföra analyserna somkrävdes var linjär regressionsanalys. Det är en statistiskanalysmetod som använder förhållanden mellan olika variabler för att skapa den räta linje som bäst visar sambandet. Detta görs genom att hitta den linje där kvadraten av mätvärdenas avvikelse från regressionslinjen ärminsta möjliga. Till prediktionsmodellen användes multipel linjär regressionsanalys som har samma tillvägagångsätt men med fler variabler.Då utomhustemperaturens påverkan på effektbehovetinte är helt linjärt utan varierar beroende på hur kallt eller varmt det är samt att även de andra faktorernas påverkan varierade gav den multipla regressionsanalysendet bästa resultatet i form av en prediktionsmodell somförklarade ungefär 80% av variationerna hos effektbehovet.

Abstract [en]

To be well prepared for the future challenges with the capacity in power grid, Umeå Energi Elnät would like to have a better understanding of the variations in energyconsumption and the reasons why it appears. In this thesis, the aim was to investigate the relations between the outside temperature and the energy demands and createa model to explain the power requirements in the grid.To achieve an appropriate model several variables thathave an impact on the energy consumption need to beused. In the end version of the model, the main variableswere outdoor temperature, month, weekday, and time ofday to predict the variations in energy consumption.Along the work two more factors were discovered thathad a large effect on the results. To make the model evenmore accurate these factors, several energy producers,and some larger consumers in Umeå Energi Elnät powergrid need to be included.To accomplish the investigations liner regression analysis was used, which is a statistical analysis method usingthe relationship between different variables creating astraight line. This is done by finding by finding the straight line there the square of the of the deviation of themeasured values from the regression line is the smallestpossible. To make the prediction model multiple regression analysis was used. It has the same approach butwith more than one variable.Since the outdoor temperature did not impact the energyconsumption completely linear but vary, and becausethere are some other factors that have large impact, multiple regression analysis gave the best prediction model.It explained 80% of the variation in power demand

Place, publisher, year, edition, pages
2021. , p. 77
Keywords [sv]
Temperaturberoende, effektbehov, prediktionsmodell, regressionanalys
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:miun:diva-42438Local ID: ET-V21-G3-062OAI: oai:DiVA.org:miun-42438DiVA, id: diva2:1574814
Subject / course
Electrical Engineering ET2
Educational program
Electric Power Engineering TEKRG 180 higher education credits
Supervisors
Examiners
Available from: 2021-06-29 Created: 2021-06-29 Last updated: 2021-06-29Bibliographically approved

Open Access in DiVA

fulltext(10917 kB)141 downloads
File information
File name FULLTEXT01.pdfFile size 10917 kBChecksum SHA-512
7a71cd24e319bb017ee42db778e0d883b883772bf1ee6f5a32c4ce08448fdb3e40747d696427a03cfb232d56db2c748c9632cb3787dd80056908bd8f62846fc9
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Torstensson, Martin
By organisation
Department of Electronics Design
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 141 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 163 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf