LoRa 868 MHz: Undersökning av terrängens inverkan på räckvidd och dataförlust samt överföring av data till SCADA-system
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.
2021 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Med ett ökande antal IoT enheter finns behov av energieffektiva metoder för överföring av data över långa avstånd. Low Power Wide Area Network (LPWAN) är ett samlingsnamn för nätverkstekniker som utvecklats för att tillgodose dessa behov. LoRa som undersökt i detta arbete är en av dessa tekniker och arbetets syfte har varit att ta reda på hur olika typer av terränger påverkar överföringen med LoRa samt vilka möjligheter det finns för att förbättra överföringen då förhållandena inte är gynnsamma. Undersökningen har genomförts genom tester där nätverksutrusning ställts upp på utvalda platser för att göra mätningar på signalstyrka och paketförlust vid skogs- och stadsmiljö samt fri sikt. Parametrar som inverkar på signalstyrka och paketförlust har varierats vid ett av testen för undersökning vid ej gynnsamma förhållanden. Att kunna på ett lämpligt sätt samla in och presentera data från en IoT-applikation är en förutsättning för att kunna dra nytta av den informationen som applikationen ger. Ett SCADA system används inom många områden till detta ändamål och arbetet innefattar även en lösning för överföring från LoRa till WinCC som är ett SCADA system. Undersökningen av LoRa har visat att längst räckvidd med bäst signalstyrka och minst paketförlust fås vid fri sikt och den terräng som ger sämst resultat är skogsterräng. Den parameter som ger mest påverkan på signalstyrkan är bandbredden och parametern spridningsfaktor ger vid ökning ett mindre antal förlorade datapaket.  

Abstract [en]

With an increasing number of IoT devices, there is a need for energy efficient methods for transferring data over long distances. The Low Power Wide Area Network (LPWAN) is a collective name for network technologies developed to meet these needs. LoRa, which has been investigated in this work, is one of these techniques. The purpose of the investigation has been to find out how different types of terrain affect the transmission with LoRa and what opportunities there are to improve the transmission when the conditions are bad. The investigation has been carried out through tests where network equipment has been placed in selected locations to make measurements on signal strength and packet loss in forest and urban environments as well as free sight. Parameters that give an impact on signal strength and packet loss have been varied in one of the tests for investigation in the case of bad conditions. Being able to collect and present data from an IoT application is a condition to get any benefits form the information from the application. A SCADA is used in many areas for this purpose and the work also includes a solution for transmission of data from LoRa to WinCC which is a SCADA system. The investigation of LoRa has shown that the longest range with the best signal strength and with the minimum number of lost packages are obtained in clear sight and the terrain that produces the worst results is forest terrain. The parameter that has the most impact on signal strength is the bandwidth and the parameter spreading factor gives a smaller number of lost data packets when increasing.

Place, publisher, year, edition, pages
2021. , p. 41
Keywords [en]
LoRa, MQTT, IoT, LPWAN
Keywords [sv]
LoRa, MQTT, IoT, LPWAN
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:miun:diva-42399Local ID: ET-V21-G3-071OAI: oai:DiVA.org:miun-42399DiVA, id: diva2:1573991
Subject / course
Electrical Engineering ET2
Educational program
Automationsingenjör TAUMG 180 GR
Supervisors
Examiners
Available from: 2021-06-28 Created: 2021-06-28 Last updated: 2021-06-28Bibliographically approved

Open Access in DiVA

fulltext(2061 kB)213 downloads
File information
File name FULLTEXT01.pdfFile size 2061 kBChecksum SHA-512
1975c81647baedc491d7cd91b36e4e1514a8f7958a2b5b1c842ddada354293fe077c4f36b7550589693d093feb24afd80b5ec6a03c3a5665a038c8b7722a2627
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Palm, Anders
By organisation
Department of Electronics Design
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 221 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 156 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf