Earthquake Early Detection as an IEEE1451 Transducer Network Trigger for Urban Infrastructure Monitoring and Protection
2020 (English)In: IEEE Instrumentation & Measurement Magazine, ISSN 1094-6969, E-ISSN 1941-0123, Vol. 23, no 9, p. 43-49, article id 9289072Article in journal (Refereed) Published
Abstract [en]

The occurrence of an earthquake has immediate consequences, such as the destruction of buildings. However, the impact can be much more severe and extend over time. The arrival of an earthquake's destructive wave can subsequently: produce a rupture in water distribution pipes, leading to water leakage, when water is even more valuable; break gas pipelines that will continue to lose gas and cause explosions leading to fires; cause the electrical power grid to come into contact with conductive structures, putting humans at risk of electrocution; or cause electrical discharges, which, in the presence of flammable materials, can give rise to fires. On the other hand, the storage of information collected by sensors that monitor the forces and deformations to which the building structure is subjected during the earthquake, allows engineers to know its state of health, right after the occurrence of the earthquake, making it possible to draw conclusions about the safety level of the building, not only for the immediate rescue, but also to execute the recovery and stabilization work [1], [2]. © 1998-2012 IEEE.

Place, publisher, year, edition, pages
Institute of Electrical and Electronics Engineers Inc. , 2020. Vol. 23, no 9, p. 43-49, article id 9289072
Keywords [en]
Electric discharges, Electric power transmission networks, Flammable materials, Leakage (fluid), Water supply systems, Building structure, Electrical discharges, Electrical power, Stabilization works, State of health, Urban infrastructure, Water distribution pipes, Water leakage, Earthquakes
Identifiers
URN: urn:nbn:se:miun:diva-41554DOI: 10.1109/MIM.2020.9289072ISI: 000597143900008Scopus ID: 2-s2.0-85097880669OAI: oai:DiVA.org:miun-41554DiVA, id: diva2:1536207
Available from: 2021-03-10 Created: 2021-03-10 Last updated: 2021-04-29Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Carratu, M.
In the same journal
IEEE Instrumentation & Measurement Magazine

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 13 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf