An experimental characterization of time of arrival accuracy for time synchronization of medium voltage smart grid solutions
Show others and affiliations
2019 (English)In: AMPS 2019 Proceedings, Institute of Electrical and Electronics Engineers Inc. , 2019Conference paper, Published paper (Refereed)
Abstract [en]

The time synchronization of smart grid devices is a critical feature for the successful application of advanced grid monitoring and control techniques. Synchronization mechanisms based on the accurate estimation of the Time of Arrival (ToA) of network messages-sent over power line cables-are a promising solution to achieve synchronization tasks over distribution lines. In this paper, a chirp-based synchronization technique over the Medium Voltage (MV) grid has been proposed and characterized. Such approach has the benefit of not requiring the installation of a dedicated infrastructure, thanks to the exploitation of power distribution lines for the transmission of time synchronization data. The effectiveness of the approach has been experimentally evaluated on a simplified MV line available in a testing laboratory. Although, the tested chirp has a limited frequency bandwidth (80 kHz), the maximum variation of the ToA estimation is on the order of 3.5 μs, which fulfills the requirements of most smart grid applications. © 2019 IEEE.

Place, publisher, year, edition, pages
Institute of Electrical and Electronics Engineers Inc. , 2019.
Keywords [en]
Chirp modulation, Medium Voltage Distribution Grid, Performance Evaluation, Smart Grid, Time of Arrival, Time Synchronization, Electric power system measurement, Electric power transmission networks, Frequency estimation, Laboratories, Smart power grids, Synchronization, Experimental characterization, Medium voltage, Power distribution lines, Synchronization mechanisms, Synchronization technique
Identifiers
URN: urn:nbn:se:miun:diva-41385DOI: 10.1109/AMPS.2019.8897769Scopus ID: 2-s2.0-85075625009ISBN: 9781728100753 (print)OAI: oai:DiVA.org:miun-41385DiVA, id: diva2:1534024
Conference
10th IEEE International Workshop on Applied Measurements for Power Systems 2019
Note

Cited By :1; Export Date: 4 March 2021; Conference Paper

Available from: 2021-03-04 Created: 2021-03-04 Last updated: 2021-04-28Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Sisinni, E.

Search outside of DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 11 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf