Mid Sweden University

miun.sePublications
System disruptions
We are currently experiencing disruptions on the search portals due to high traffic. We are working to resolve the issue, you may temporarily encounter an error message.
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Flow injection determination of Al3+ and Al13O4(OH)(24)(H2O)(12)(7+) species using a 1.3-s reaction with 8-quinolinol-derivatised Fractogel
University of Canterbury, New Zealand.
University of Canterbury, New Zealand.
University of Canterbury, New Zealand.
1997 (English)In: Analytica Chimica Acta, ISSN 0003-2670, E-ISSN 1873-4324, Vol. 343, no 1-2, p. 19-32Article in journal (Refereed) Published
Abstract [en]

Speciation of Al is determined by a 1.3-s reaction with 8-quinolinol (oxine)-derivatised Fractogel in a 22 μl column reactor in a flow injection (FI) manifold. Al (pre)concentrated on the column from a 650 μl sample is selectively eluted with 250 μl of 0.02 M NaOH and detected spectrophotometrically as the Al-chrome azurol S (CAS) complex at pH 5.0. This Al (referred to as ‘free Al’) comprises Al3+ + A1(OH)2+ + Al in very labile complexes. Tests with synthetic solutions established that Al is not significantly sequestered from the citrate, oxalate and malonate complexes. Al-hydroxo polymers [Al13(OH)327+] are quantitatively retained by the column but are not desorbed by 0.02 M NaOH in the time frame of the FI method; therefore they do not contribute to the analytical signal. However, they can be quantified after stopped-flow elution with 0.2 M NaOH. The AlF2+ and AlF2+ complexes are retained and eluted quantitatively and therefore contribute to the measurement of ‘free Al’. The method has been applied to humic waters and soil solutions and the results for ‘free’ Al3+ compared with those obtained by the 7-s CAS method. The method has a 2σ detection limit of 70 nM, a linear working range of 0.3–16 μM and relative standard deviations of 7% and 1% at 0.5 and 16 μM, respectively.

Place, publisher, year, edition, pages
1997. Vol. 343, no 1-2, p. 19-32
Keywords [en]
Flow injection, Aluminum, 8-Quinolinol-derivatised Fractogel
National Category
Environmental Sciences
Identifiers
URN: urn:nbn:se:miun:diva-34493DOI: 10.1016/S0003-2670(96)00583-1ISI: A1997XB09600003OAI: oai:DiVA.org:miun-34493DiVA, id: diva2:1250887
Available from: 2018-09-25 Created: 2018-09-25 Last updated: 2018-09-25Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Nilsson, Nils

Search in DiVA

By author/editor
Nilsson, Nils
In the same journal
Analytica Chimica Acta
Environmental Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 138 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf