Klimatstyrd vedgårdsbevattning: Utvärdering av befintligt och framtaget koncept: Styrsystem och beräkningsmodell
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.
2018 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Långtidslagring av virke behövs för att säkerställa produktionen av bland annat papper. Under lagringsperioden finns det risk för att virket torkar ut och därmed blir kontaminerat. För att undvika detta kan virket bevattnas beroende på väder. Syftet med undersökningen har varit att klargöra nödvändiga väderparametrar samt utreda hur dessa kan implementeras i Siemens mjukvara, PCS 7. Förutom detta har syftet även varit att jämföra kostnader mellan olika systemuppställningar. Undersökningen visade att det finns relativt mycket olika typer av avdunstningsmodeller. Tre modeller jämfördes med liknande väderdata. Där sedan avdunstningsformeln från Cheng och Cheng valdes för att de hade störst spridning på avdunstningsvärdena relaterat till temperatur och luftfuktighet. Därefter togs en formel fram för bevattningstiden, där flöde och kastlängd varierade med vattentryck. Beräknade bevattningstider jämfördes sedan med en undersökning relaterad till den maximala avdunstningen från fri vattenyta. Från detta konstaterades det att framtagen beräkningsmodell ligger i linje med den maximala avdunstningen. För att kunna ta in data till Siemens PCS 7 utreddes två alternativ, nyttja en öppen databas från SMHI, alternativt använda en lokal väderstation med en standardiserad signal, 4-20mA.  Det visade sig att det är möjligt att använda öppen databas från SMHI, men på grund av Holmens säkerhetspolicy kunde inte styrsystemet anslutas till internet. På grund av detta användes istället standardiserade givare, men även för att SMHI inte kunde leverera kontinuerliga data och dessutom inte med hög träffsäkerhet. På grund av sekretess kunde inte kostnader presenteras i rapporten.

Abstract [en]

Longtime storage of roundwood is needed to provide a reliable production. During the storage period, there is a risk that the roundwood gets hydrated and thereby contaminated. To avoid this, the roundwood can be watered due to the weather. The purpose of this survey has been to clarify necessary weather parameters and investigate how to implement them into Siemens software, PCS 7. Additionally, the purpose has been to compare costs between different system configurations. The survey showed that there are a lot of different types of evaporation models. Three models were compared with similar data. Finally, the formula by Cheng and Cheng were chosen, because it had the greatest spread between the evaporation values related to temperature and humidity. Later a calculation model was constructed, where the flow and radius variated by pressure. Calculated watering intervals were then compared with a survey related to the maximum evaporation from freely available water surface. It was then stated that the formula is in line with the maximum evaporation. Two alternatives were analyzed to be able to present the data in Siemens PCS 7, make use of an open data base by SMHI, or use a local weather station with a standardized signal, 4-20mA. The analyze showed that it is possible to use an open data base but due to Holmen’s safety policy, the system could not be connected to internet. Therefore, regular sensors with standardized signal where chosen, but also because SMHI could not provide real time data with high reliability. The costs could not be presented due to secrecy.

 

Place, publisher, year, edition, pages
2018. , p. 97
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:miun:diva-34337Local ID: ET-V18-G3-014OAI: oai:DiVA.org:miun-34337DiVA, id: diva2:1245042
Subject / course
Electrical Engineering ET2
Educational program
Automationsingenjör TAUMG 180 GR
Supervisors
Examiners
Available from: 2018-09-04 Created: 2018-09-04 Last updated: 2018-09-04Bibliographically approved

Open Access in DiVA

fulltext(4554 kB)38 downloads
File information
File name FULLTEXT01.pdfFile size 4554 kBChecksum SHA-512
45db9c10289c139b18096ab89837f7a97b31dabff6e74e8c6d078812864df340ee78057ac4ad7bf3e02ad7edc9615d13a62d35f1d834bb06003754f1d2102862
Type fulltextMimetype application/pdf

By organisation
Department of Electronics Design
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 38 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 63 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf