Mid Sweden University

miun.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
On the importance of controlling film architecture in detecting prostate specific antigen
Federal University of São Carlos, Center for Sciences and Technology for Sustainability, Sorocaba, SP, Brazil.
Federal University of São Carlos, Center for Sciences and Technology for Sustainability, Sorocaba, SP, Brazil.
University of São Paulo, São Carlos, SP, Brazil.
Mid Sweden University, Faculty of Science, Technology and Media, Department of Natural Sciences.
Show others and affiliations
2018 (English)In: Applied Surface Science, ISSN 0169-4332, E-ISSN 1873-5584, Vol. 434, p. 1175-1182Article in journal (Refereed) Published
Abstract [en]

Immunosensors made with nanostructured films are promising for detecting cancer biomarkers, even at early stages of the disease, but this requires control of film architecture to preserve the biological activity of immobilized antibodies. In this study, we used electrochemical impedance spectroscopy (EIS) to detect Prostate Specific Antigen (PSA) with immunosensors produced with layer-by-layer (LbL) films containing anti-PSA antibodies in two distinct film architectures. The antibodies were either adsorbed from solutions in which they were free, or from solutions where they were incorporated into liposomes of dipalmitoyl phosphatidyl glycerol (DPPG). Incorporation into DPPG liposomes was confirmed with surface plasmon resonance experiments, while the importance of electrostatic interactions on the electrical response was highlighted using the Finite Difference Time-Domain Method (FDTD). The sensitivity of both architectures was sufficient to detect the threshold value to diagnose prostate cancer (ca. 4 ng mL−1). In contrast to expectation, the sensor with the antibodies incorporated into DPPG liposomes had lower sensitivity, though the range of concentrations amenable to detection increased, according to the fitting of the EIS data using the Langmuir-Freundlich adsorption model. The performance of the two film architectures was compared qualitatively by plotting the data with a multidimensional projection technique, which constitutes a generic approach for optimizing immunosensors and other types of sensors. 

Place, publisher, year, edition, pages
2018. Vol. 434, p. 1175-1182
Keywords [en]
Electrochemical impedance spectroscopy, Finite difference time-domain method, Immunosensor, Layer-by-layer, Liposome
National Category
Materials Engineering
Identifiers
URN: urn:nbn:se:miun:diva-32286DOI: 10.1016/j.apsusc.2017.10.122ISI: 000419116600135Scopus ID: 2-s2.0-85033572501OAI: oai:DiVA.org:miun-32286DiVA, id: diva2:1163209
Available from: 2017-12-06 Created: 2017-12-06 Last updated: 2019-08-06Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Volpati, Diogo

Search in DiVA

By author/editor
Volpati, Diogo
By organisation
Department of Natural Sciences
In the same journal
Applied Surface Science
Materials Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 109 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf