Mid Sweden University

miun.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
En studie om remissförslagen från Boverket gällande nära‐nollenergibyggnader
Mid Sweden University, Faculty of Science, Technology and Media, Department of Ecotechnology and Sustainable Building Engineering.
Mid Sweden University, Faculty of Science, Technology and Media, Department of Ecotechnology and Sustainable Building Engineering.
2017 (Swedish)Independent thesis Basic level (degree of Bachelor of Fine Arts), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Enligt Europaparlamentets och rådets direktiv (2010/31/EU)

ska samtliga medlemsstater i EU skärpa kraven på

byggnaders energiförbrukning för att säkerställa en hållbar

utveckling och en energieffektivare union. Direktivet kräver

att alla medlemsstater ska införa krav så att samtliga

nyproducerade byggnader och lokaler som uppförs ska vara

nara--‐nollenergibyggnader vid slutet av 2020.

Boverket har arbetat fram direktiv (BFS 2017:xx BBR (A); BFS

2017:xx BBR (B); BFS 2017:xx BEN 2) som ska styra hur

energiförbrukning ska beräknas och vilka kravnivåer som

ska vara gällande för nara--‐nollenergibyggnader i Sverige.

Denna studie kommer att analysera vad de nya kraven

innebär för två olika leverantörer och respektive leverantörs

prefabricerade massivträväggar. Väggsystemen appliceras

på en referensbyggnad där tak, grund, fönster och dörrar är

förbestämda, det enda som varierar i referensbyggnaden är

väggsystemen.

Väggsystemen som analyserats är Isotimbers vägg Per-Albin

2.0 och Martinsons vägg YV-16-01. Isotimber har en produkt

som består av massivträ med urfrästa luftkanaler som ska ge

en ökad isolering (Isotimber, 2016). Martinsons tillverkar

korslimmade träelement som bildar formstabila

byggnadselement (Martinsons, u.å.a).

För att nå ett resultat har handberäkningar av U-värden,

energianvändning samt primärenergital utförts. Uträkningar

är baserat på lagtext, vilket innefattar formler och

schablonvärden från Boverket. Studien har även inkluderat

litteratur som exempelvis energihushållning och

värmeisolering (Elmroth, 2015), byggnaden som system

(Adel, E., & Elmroth, A. 2012) med flera.

Resultatet visar att väggsystemen inte uppfyller de nya

kraven för nara--‐nollenergibyggnader enligt Boverket

byggregler.

Abstract [en]

According to the European Parliament and the Councils

directive (2010/31/EU) all EU member states must tighten

their energy consumption requirements for buildings to

ensure a sustainable development and an energy-efficient

union. The directive requires all member states to introduce

directives so that all newly built constructions will be near‑zero energy‑buildings by the end of 2020.

Boverket has developed directives (BFS 2017: xx BBR (A);

BFS 2017: xx BBR (B); BFS 2017: xx BEN 2) to determine how

energy consumption should be calculated and what

requirements will apply to near‑zero energy‑buildings in

Sweden.

This report will analyse what these new directives mean for

two standard wall system solutions from two suppliers of

prefabricated solid wood walls. The wall systems are applied

to a reference building where the ceiling, foundation,

windows and doors are predetermined, the only parameter

that varies is the wall systems.

The wall systems analysed are Isotimber'ʹ wall Per‑Albin 2.0

and Martinsons wall YV-16-01. Isotimber has a product

consisting of solid woodblocks with milled slots for

increased insulation (Isotimber, 2016). Martinsons

manufactures cross‑laminated timber elements that makes

form‑stable sheets of solid wood (Martinsons, u.å.a).

In order to achieve results, hand calculations of U‑values,

energy consumption and primary energy have been

performed. Calculations are based on legal texts, formulas

and standard values from the workplace as well as literature

studies, for example energihushållning och värmeisolering

(Elmroth 2015), byggnaden som system (Adel, E., & Elmroth,

A. 2012) among others.

The result shows that none of the wall systems will meet the

new requirements for near‑zero energy buildings with this

design on the reference building and with these wall

systems.

Place, publisher, year, edition, pages
2017. , p. 58
Keywords [en]
BFS 2017:xx BBR (A), BFS 2017:xx BBR (B), BFS 2017:xx BEN 2, Near-zero energy Buidlding, MArtinsons, CLT, Isotimber
Keywords [sv]
BFS 2017:xx BBR (A), BFS 2017:xx BBR (B), BFS 2017:xx BEN 2, Nära-nollenergibyggnader, NNE, Martinsons, KL-trä, Isotimber
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:miun:diva-31516DOI: BT-V17-G3-003OAI: oai:DiVA.org:miun-31516DiVA, id: diva2:1137739
Subject / course
Building Engineering BY1
Educational program
Building Engineering Sustainable Building TBYHG 180 higher education credits
Supervisors
Examiners
Note

Betyg 170814, H14.

Available from: 2018-08-30 Created: 2017-09-01 Last updated: 2018-08-30Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Search in DiVA

By author/editor
Carlsson, FridaTenggren, Jonatan
By organisation
Department of Ecotechnology and Sustainable Building Engineering
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 255 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf