Kontaktlös flödesmätning med trådlös dataöverföring: Undersökning av kostnadseffektiva system
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.
2017 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Målet med undersökningen har varit att undersöka möjligheten att ta fram en kostnadseffektiv lösning för att mäta flöden i slutna rörsystem. Anledningen till att kontaktlösa metoder valts för arbetet är dess egen-skaper att kunna installeras utan att göra ingrepp i ledningarna eller på något sätt påverka det flödande mediet i dessa. Utrustning skall inhand-las och testas i fält. I underökningen ingår det även att ta fram en lämplig metod för att trådlöst överföra insamlat mätdata till valfri IT-miljö och där kunna presentera mätdata på ett översiktligt sätt i ett övervaknings-system samt använda mätdatat till olika statistiska beräkningar. Det hu-vudsakliga applikationsområdet som undersöks är läckageindikering i dricksvattenledningsnät. Anledningen till detta är att många kommuner inte har råd att investera i dyr mätutrustning för övervakning och för dem kan det vara intressant med ett billigt system som är relativt enkelt att installera och implementera i deras befintliga övervakningssystem. Re-sultat av en enkätundersökning som gjorts i samband med undersök-ningen har visat att intresset är stort hos kommunerna, men den visar även att övervakning av vattenledningsnäten med vissa traditionella me-toder kommer att bli svårare i framtiden i och med den stigande andelen plaströr i ledningsnäten. Fälttester av inköpt mätutrustning visar att den skulle kunna implementeras och fungera som flödesövervakning i led-ningsnät. Även fast dess mätnoggrannhet var under det förväntade så vi-sade utrustningen på god linjäritet.

Abstract [en]

The aim of the survey has been to investigate the possibilities of using a cost-effective solution for measuring flows in closed pipes. Non-intrusive measuring methods are chosen because it’s able to install them without interfering the flow in- or alter- the pipe in any way. Equipment will be purchased and field tested during the time of the survey. The survey also includes investigating suitable methods for wirelessly transmitting col-lected data to an IT-environment, and using measurement data for sur-veillance purposes and various statistical calculations. The main applica-tion area investigated is leakage indication in drinking water pipeline net-works, the reason being that many municipalities can’t afford to invest in expensive measuring equipment and they may be interested in an inex-pensive system that is relatively easy to install and implement in their existing monitoring system. The results of a poll conducted in connection with the survey have shown that there is considerable interest among the municipalities, but it also shows that monitoring of the water supply net-works with traditional methods may become more difficult in the future, the main reason for this seems to be the increasing amount of plastic pipe-lines in the pipeline networks. Field tests of the purchased equipment show that it may be suitable to implement as flow measuring device with the purpose of leakage monitoring, even though its measurement accu-racy was below expected it still shows good linearity.

Place, publisher, year, edition, pages
2017. , p. 64
Keywords [en]
Non-intrusive flow measuring, ultrasonic, water pipeline net-works, leakage detection, data logger
Keywords [sv]
Kontaktlös flödesmätning, ultraljud, vattendistribution, läck-sökning, datalogger
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:miun:diva-31481Local ID: ET-V17-G3-017OAI: oai:DiVA.org:miun-31481DiVA, id: diva2:1135823
Subject / course
Electrical Engineering ET2
Educational program
Automationsingenjör TAUMG 180 GR
Supervisors
Examiners
Available from: 2017-08-24 Created: 2017-08-24 Last updated: 2017-08-24Bibliographically approved

Open Access in DiVA

fulltext(2188 kB)85 downloads
File information
File name FULLTEXT01.pdfFile size 2188 kBChecksum SHA-512
e79369a5c1475d129c335bf05670463bcf88fc059b6bbe9798f532bef71611e7e540c7c8a20b069c14c310357aa148603a8e85372b1e4c3318716d938e62b91b
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Svensson, Sonny
By organisation
Department of Electronics Design
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 85 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 65 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf