Styrning av värmepanna med PLC: Från relästyrning till digital styrning
Mid Sweden University, Faculty of Science, Technology and Media, Department of Electronics Design.
2017 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

På det kommunalägda energiföretaget Sala Heby Energi AB pågår arbetet med att konvertera styrningen av en värmepanna från relästyrning och analog övervakning till digital styrning med PLC. Inom ramarna för detta examensarbete studeras tre specifika delar av denna konvertering: en teoretisk studie med syfte att kartlägga fördelar och nackdelar med konverteringen, en undersökning huruvida det finns möjlighet att förbättra en-skilda styrfunktioner i samband med konverteringen och upprättande av ett principschema eller översiktsbild över värmepannan som ska fungera som underlag till dess implementering i kraftvärmeverkets SCADA-system. En fördel med relästyrningen är att den kan vara kostnadseffektiv för att klara enskilda enkla styruppgifter. Dock, överlag och i synnerhet för styrning av större mer komplexa processer talar det mesta till den digitala styrningens fördel. Detta i form av kostnadseffektivitet för större system, möjligheter till mer effektiv larmhantering och möjligheten till loggning av driftdata. Två enskilda funktioner studeras: reglering av värmepannans siktskärm i förhållande till ångdomstrycket och styrning för bränslehanteringen. För reglering av siktskärmens höjd jämförs två alter-nativ med hjälp av simuleringar i Simulink. Konventionell PID-reglering jämförs mot en egenkonstruerad fuzzy-regulator. Mycket på grund av en bristfälligt underbyggd modellering av processen går inte fuzzy-regulatorns eventuella fördelar mot PID-regulatorn att fastställa. Framtida studier av fuzzy-regulatorn skulle potentiellt kunna ändra på detta förhållande. Vidare diskuteras styrningen av funktioner i bränslehantering och då främst autentisering av chaufförer som ska bränslefylla. För att de ska få tillgång till bränslehanteringens funktioner när kraftvärmeverket är obemannat föreslås det en lösning med nyckelbrytare för att aktivera aktuella styrfunktioner. Slutligen tas en ny digital översiktsbild fram över systemet för värmepannan. Denna innehåller mindre uppdateringar och anpassningar jämfört med två översiktsbilder som finns uppritade på de gamla styrskåpen.

Abstract [en]

At the municipality-owned energy company Sala Heby Energi AB work is underway to convert the control of a heating-pan from relay control and analog monitoring to digital control with PLC. Within the framework of this degree project, three specific parts of this conversion are studied: a theoretical study aimed at mapping the pros and cons of the conversion, an examination of the possibility of improving individual control functions in conjunction with the conversion and the establishment of a schematic diagram or overview of the heat boiler that will serve as a basis for its implementation in the SCADA-system of the combined power and heating plant. An advantage of relay control is that it can be cost-effective to handle individual simple control tasks. However, overall and in particular for controlling major more complex processes the benefits of digital control is large. This in terms of cost-effectiveness for larger systems, possibilities for more efficient alarm management and the ability to log operational data. Two individual functions are studied: control of the heating pans damper in relation to the steam pressure and fuel management control. To adjust the height of the damper, two control options are compared using Simulink simulations. Conventional PID control is com-pared to a self-configured fuzzy controller. Much due to a poorly substantiated modelling of the process, the fuzzy regulator's possible benefits to the PID regulator can not be determined. Future studies of the fuzzy regulator could potentially change this circumstance. Furthermore, the control of functions for the fuel management are discussed, mainly authorship of drivers who will fill fuel to the fuel storage. In order for them to have access to the fuel management functions when the combined power and heating plant is unmanned, a key switch solution is proposed to activate the control functions. Finally, a new digital overview picture is produced for the system of the heating pan. This contains minor up-dates and adjustments compared to two overview images depicted on the old control cabinets.

Place, publisher, year, edition, pages
2017. , 75 p.
Keyword [en]
Combined power and heating plant, heating-pan, relay-control, PLC, SCADA.
Keyword [sv]
Kraftvärmeverk, värmepanna, relästyrning, PLC, SCADA
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:miun:diva-31091Local ID: ET-V17-G3-018OAI: oai:DiVA.org:miun-31091DiVA: diva2:1117915
Subject / course
Electrical Engineering ET2
Educational program
Automationsingenjör TAUMG 180 GR
Supervisors
Examiners
Available from: 2017-06-29 Created: 2017-06-29 Last updated: 2017-06-29Bibliographically approved

Open Access in DiVA

fulltext(3610 kB)7 downloads
File information
File name FULLTEXT01.pdfFile size 3610 kBChecksum SHA-512
d53633fd14ae331c85e85a818cf7e77bacde611ba401c6acf5a774bbd4ccedb20abeb353c80b9a358dd4b39b50abb400dc71accca14a9307863ee6f1ca2370ca
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Öström, Daniel
By organisation
Department of Electronics Design
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 7 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 8 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf