miun.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Tillräcklig tilläggsisolering: En studie om att uppfylla BBR kraven enligt 9.92 och vilka följdeffekter det har på den relativa ånghalten i konstruktionen
Mid Sweden University, Faculty of Science, Technology and Media, Department of Ecotechnology and Sustainable Building Engineering.
2016 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

I denna rapport kommer det att undersöka vid vilken tjocklek tilläggsisoleringen måste vara för att uppfylla Boverkets byggreglers(BBR) krav om energihushållning för en specifik byggnadsdel. Byggnadsdelarna kommer att vara hämtade ur Energimyndighetens rapport om tilläggsisolering. Valda byggnadsdelar är ytterväggar av träregeltyp med fasader av träpanel samt ventilerad luftspalt, isoleringen består av antingen spån eller av mineralull. Vindsbjälklagen anses som uteluftsventilerade med ett oskyddat isoleringsskikt ut mot den fria luften i kallvinden, de har ett regelavstånd på s1200mm och isoleringsmaterialet är antingen spån eller mineralull. Tilläggsisoleringen kommer att bestå av mineralull i skivor för ytterväggskonstruktionerna och som lösull för vindsbjälklagen. De beräkningsverktyg som kommer att användas för att kontrollera effekterna av tilläggsisoleringen i fukthänseende är generella fuktberäkningar enligt normalvärdesmetoden utvalda och genom ångmotstånd beräknade värden för ånghalten i skikten mellan olika byggnadsmaterial. För beräkningen av U-värdet kommer beräkningar med värmegenomgångsmotstånd att användas samt att approximationerna till det totala motståndet kommer att beräknas med både lambda- och U-värdesmetoden. Resultatet visar att U-värdet sjunker när isoleringens tjocklek ökar. Samtidigt höjs temperaturen i den ursprungliga konstruktionen vilket medför att den relativa fukthalten minskar. Vid tilläggsisolering av väggkonstruktionerna uppfylls BBRs krav vid 120 mm isolering med mineralull. För vindsbjälklag uppfylls kraven vid 150 mm oberoende på grundutförande. I fallen med vindsbjälklagen ser man även att förbättringen i U-värdet är så liten vid 250 till 300 mm och 300 till 350 mm beroende på konstruktion att det inte kan redovisas med två decimalers noggrannhet. Samtidigt som isolerings mängden ökar minskar den relativa ånghalten.

Abstract [en]

This report will examine at which the thickness of the additional insulation must be to meet the Swedish building regulations (BBR) requirements on energy management for a specific building element. Construction parts will be taken from the Energy Agency’s report on the additional insulation. The selected parts are the building's exterior walls constructed of wood stud type with facades of wood paneling and ventilated air space beneath, the insulation consists of either woodchips or mineral-wool. The attic is considered as an outdoor-ventilated space with an unprotected insulation layer towards the free air in the attic. Attic has a beam distance of s1200 mm and insulation material is either woodchips or mineral wool. Additional insulation will consist of mineral-wool panels for exterior wall constructions and loos mineral-wool grains for the attic. The computational tools that will be used to check the effects of adding insulation in regard to the moisture, general moisture calculations thru the normal values method selected and by steam resistance calculated values for the vapor content in the layers between different building materials. For the calculation of the U value, calculations of the heat transfer resistance will be used and the approximations to the total resistance will be calculated using both lambda and U-value method to get as close to the real answer as possible. The results show that U-value drops when the insulation thickness increases. At the same time, the temperature in the initial design increases, which means that the relative humidity decreases. The additional insulation of wall structures met BBR's requirements at 120 mm insulation with mineral-wool. The attic floor met the requirements at 150 mm independently of the basic design. In the cases of the attics the improvements in the U-values are so small at 250 to 300 mm and 300 to 350 mm that depending on the design the change in U-values can not be shown in regards to the requirements of two decimal U-values. While the isolation amount increases, the relative vapor content decreases.

 

Place, publisher, year, edition, pages
2016. , p. 63
Keywords [sv]
Tilläggsisolering, U-värde, Fukt, Relativ ånghalt
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:miun:diva-30504DOI: BT-V16-G3-014OAI: oai:DiVA.org:miun-30504DiVA, id: diva2:1085179
Subject / course
Building Engineering BY1
Educational program
Building Engineering Sustainable Building TBYHG 180 higher education credits
Supervisors
Examiners
Available from: 2018-08-30 Created: 2017-03-28 Last updated: 2018-08-30Bibliographically approved

Open Access in DiVA

fulltext(1661 kB)10 downloads
File information
File name FULLTEXT01.pdfFile size 1661 kBChecksum SHA-512
2aa2342c51d2ac02842271e4aa8496470631f99b21ec973eafabc7b5caccf735ab0aff0c7b30a68a5b0b419ada1be9155ce4a481f0a37c9f6a83a4b0ae68cedb
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Search in DiVA

By author/editor
Sundelin, Andreas
By organisation
Department of Ecotechnology and Sustainable Building Engineering
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 10 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 17 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf